This paper describes the design and development of a high-resolution pressure sensor for use in the field of foot pressure measurement. The device uses an interferometry technique that involves the use of a laser Light directed onto a pressure sensitive plate. The pressure plate compresses when a load is applied, and it is this compression which is measured by the interferometry technique. The interference pattern (interferogram) produced represents the pressure distribution across the plate. The interferogram is inputted into the computer using a high pixel CCD camera and video capture card. A fringe analysis program then converts the interferogram into a three-dimensional image of the pressure distribution. A prototype system is described and the initial results show that the system can produce a high resolution image with dynamic capabilities. (C) 2000 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 15 条
  • [1] [Anonymous], 1987, FOOT DIABETES
  • [2] CAVANAGH P.R., 1992, INT J CLIN FOOT SCI, V2, P185, DOI [10.1016/0958-2592(92)90047-S, DOI 10.1016/0958-2592(92)90047-S, 10.1016/0958-2592, DOI 10.1016/0958-2592]
  • [3] RELIABILITY OF PRESSURE MEASUREMENTS - THE EMED F SYSTEM
    HUGHES, J
    PRATT, L
    LINGE, K
    CLARK, P
    KLENERMAN, L
    [J]. CLINICAL BIOMECHANICS, 1991, 6 (01) : 14 - 18
  • [4] TOWARDS LESS AMPUTATIONS IN DIABETIC-PATIENTS - INCIDENCE, CAUSES, COST, TREATMENT, AND PREVENTION - A REVIEW
    LARSSON, J
    APELQVIST, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (02): : 181 - 192
  • [5] LEVIN ME, 1993, MOSBY YB, V31
  • [6] FOOT PRESSURE MEASUREMENT - A REVIEW OF CLINICAL FINDINGS
    LORD, M
    REYNOLDS, DP
    HUGHES, JR
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (04): : 283 - 294
  • [7] FOOT PRESSURE MEASUREMENT - A REVIEW OF METHODOLOGY
    LORD, M
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1981, 3 (02): : 91 - 99
  • [8] McPoil T. G., 1995, LOWER EXTREMITY, V2, P95
  • [9] A COMPARISON OF THE DYNAMIC PEDOBAROGRAPH AND EMED SYSTEMS FOR MEASURING DYNAMIC FOOT PRESSURES
    QUANEY, B
    MEYER, K
    CORNWALL, MW
    MCPOIL, TG
    [J]. FOOT & ANKLE INTERNATIONAL, 1995, 16 (09) : 562 - 566
  • [10] TAKEDA M, 1981, OPTICAL SOC AM, V72, P155