Reproducibility of computer-quantified carotid plaque echogenicity - Can we overcome the subjectivity?

被引:149
作者
Sabetai, MM
Tegos, TJ
Nicolaides, AN
Dhanjil, S
Pare, GJ
Stevens, JM
机构
[1] St Marys Hosp, Imperial Coll, Sch Med, Irvine Lab Cardiovasc Invest & Res,Dept Vasc Surg, London W2 1NY, England
[2] St Marys Hosp, Imperial Coll, Sch Med, Dept Radiol, London W2 1NY, England
关键词
carotid stenosis; echogenicity; reproducibility; ultrasonography;
D O I
10.1161/01.STR.31.9.2189
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-We sought to assess the reproducibility, interobserver variability, and application to clinical studies of a new method for the quantitative assessment of carotid plaque echogenicity. Methods-Carotid plaques were scanned with the use of ultrasound, and their images were stored in a computer, They were normalized by assigning certain gray Values to blood and adventitia, and the gray scale median (GSM) was used to quantify their echogenicity. The variability between storage media, between degrees of magnification, and between probes was assessed. The method was applied to 232 asymptomatic carotid plaques causing 60% to 99% stenosis in relation to the presence of ipsilateral CT-demonstrated brain infarcts. In all parts of the study the plaque GSM was measured before and after normalization to evaluate its effect. Interobserver agreement for the scanning process was assessed. Results-The GSM mean difference before and after normalization for variability studies of storage media, degrees of magnification, and probes was - 14.5 and -0.12, 2.24 and 1.68, and -8.3 and -0.7, respectively. The median GSM of plaques associated with ipsilateral nonlacunar silent CT-demonstrated brain infarcts was 14, and that of plaques that were not so associated was 30 (P=0.003). The interobserver GSM difference was -0.05 (95% CI, -1.7 to 1.6). Conclusions-Our method decreases the variability between storage media and between probes but not the variability between degrees of magnification. It separates echomorphologically the carotid plaques associated with silent nonlacunar CT-demonstrated brain infarcts from plaques that are not so associated.
引用
收藏
页码:2189 / 2196
页数:8
相关论文
共 55 条
[1]  
[Anonymous], 1993, Stroke, V24, P527
[2]   Carotid plaque characterization by duplex scanning - Observer error may undermine current clinical trials [J].
Arnold, JAC ;
Modaresi, KB ;
Thomas, N ;
Taylor, PR ;
Padayachee, TS .
STROKE, 1999, 30 (01) :61-65
[3]   Computer analysis of ultrasonic plaque echolucency in identifying high risk carotid bifurcation lesions [J].
Biasi, GM ;
Sampaolo, A ;
Mingazzini, P ;
De Amicis, P ;
El-Barghouty, N ;
Nicolaides, AN .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 17 (06) :476-479
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Complications in carotid endarterectomy are predicted by qualifying symptoms and preoperative CT findings [J].
Blohmé, L ;
Sandström, V ;
Hellström, G ;
Swedenborg, J ;
Takolander, R .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1999, 17 (03) :213-218
[6]   THE NATURAL-HISTORY OF ASYMPTOMATIC CAROTID-ARTERY DISEASE [J].
BOCK, RW ;
GRAYWEALE, AC ;
MOCK, PA ;
STATS, MA ;
ROBINSON, DA ;
IRWIG, L ;
LUSBY, RJ ;
PERLOFF, LJ ;
GREENHALGH, RM .
JOURNAL OF VASCULAR SURGERY, 1993, 17 (01) :160-171
[7]   THE PLURALITY OF SUBCORTICAL INFARCTION [J].
BOGOUSSLAVSKY, J .
STROKE, 1992, 23 (05) :629-631
[8]  
BOGOUSSLAVSKY J, 1992, NEUROLOGY, V42, P1992
[9]  
BRESLAU PJ, 1981, ULTRASONIC DUPLEX SC
[10]   Cerebral tomographic findings in patients undergoing carotid endarterectomy for asymptomatic carotid stenosis: short-term and long-term implications [J].
Cao, P ;
Zannetti, S ;
Giordano, G ;
De Rango, P ;
Parlani, G ;
Caputo, N .
JOURNAL OF VASCULAR SURGERY, 1999, 29 (06) :995-1004