A real-time optimal control strategy for multi-zone VAV air-conditioning systems adopting a multi-agent based distributed optimization method

被引:48
作者
Li, Wenzhuo [1 ]
Wang, Shengwei [1 ]
Koo, Choongwan [2 ]
机构
[1] Hong Kong Polytech Univ, Res Inst Smart Energy, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[2] Incheon Natl Univ, Div Architecture & Urban Design, Incheon, South Korea
关键词
Distributed optimal control; Multi-agent system; Thermal comfort; Indoor air quality; Energy efficiency; Air-conditioning systems;
D O I
10.1016/j.apenergy.2021.116605
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Determining the proper trade-off among thermal comfort, Indoor Air Quality (IAQ) and energy use is important for optimal control of air-conditioning systems. The number of optimization variables increases as systems become increasingly complex, as with multi-zone VAV (Variable Air Volume) air-conditioning systems, leading to large-scale mathematics programming challenges and inconveniences in the implementation of conventional centralized optimization strategies. This paper therefore proposes a real-time optimal control strategy adopting a multi-agent based distributed optimization method for multi-zone VAV air-conditioning systems. The proposed strategy consists of three novel schemes. First, a temperature set-point reset scheme adopts a linear rule to correlate the resetting of the temperature set-points in individual zones to simplify the optimization problem while applying proper optimization in individual zones. Second, a multi-objective optimization scheme optimizes the fresh air ratio of the supply air and the temperature set-point in the critical zone by formulating the multi objective optimization problem. Third, a multi-agent distributed optimization scheme is developed to solve the optimization problem in a distributed manner, facilitating the deployment of local control devices of limited capacity. A TRNSYS-MATLAB co-simulation testbed is constructed to test and validate the proposed strategy. Test results show that the strategy is effective in properly balancing thermal comfort, IAQ and energy use while largely reducing programming challenges. The distributed optimization method can provide almost the same optimal outputs as conventional centralized optimization methods.
引用
收藏
页数:14
相关论文
共 41 条
  • [1] Multiplexed real-time optimization of HVAC systems with enhanced control stability
    Asad, Hussain Syed
    Yuen, Richard Kwok Kit
    Huang, Gongsheng
    [J]. APPLIED ENERGY, 2017, 187 : 640 - 651
  • [2] ASHRAE S, 6212016 ASHRAES
  • [3] Alternative ventilation strategies in US offices: Saving energy while enhancing work performance, reducing absenteeism, and considering outdoor pollutant exposure tradeoffs
    Ben-David, Tom
    Rackes, Adams
    Waring, Michael S.
    [J]. BUILDING AND ENVIRONMENT, 2017, 116 : 140 - 157
  • [4] Impact of natural versus mechanical ventilation on simulated indoor air quality and energy consumption in offices in fourteen US cities
    Ben-David, Tom
    Waring, Michael S.
    [J]. BUILDING AND ENVIRONMENT, 2016, 104 : 320 - 336
  • [5] Distributed optimization and statistical learning via the alternating direction method of multipliers
    Boyd S.
    Parikh N.
    Chu E.
    Peleato B.
    Eckstein J.
    [J]. Foundations and Trends in Machine Learning, 2010, 3 (01): : 1 - 122
  • [6] A general multi-agent control approach for building energy system optimization
    Cai, Jie
    Kim, Donghun
    Jaramillo, Rita
    Braun, James E.
    Hu, Jianghai
    [J]. ENERGY AND BUILDINGS, 2016, 127 : 337 - 351
  • [7] Cai J, 2016, P AMER CONTR CONF, P2365, DOI 10.1109/ACC.2016.7525271
  • [8] Optimization of mine ventilation fan speeds according to ventilation on demand and time of use tariff
    Chatterjee, Arnab
    Zhang, Lijun
    Xia, Xiaohua
    [J]. APPLIED ENERGY, 2015, 146 : 65 - 73
  • [9] Davarzani S, 2019, APPL ENERGY, V253, P1
  • [10] Environment Bureau, 2019, EN SAV CHART 2019