Comparative measurements of bone mineral density and bone contrast values in canine femora using dual-energy X-ray absorptiometry and conventional digital radiography

被引:7
作者
Lucas, K. [1 ]
Nolte, I. [1 ]
Galindo-Zamora, V. [2 ]
Lerch, M. [3 ]
Stukenborg-Colsman, C. [3 ]
Behrens, B. A. [4 ]
Bouguecha, A. [4 ]
Betancur, S. [4 ]
Almohallami, A. [4 ]
Wefstaedt, P. [1 ]
机构
[1] Univ Vet Med Hannover, Small Anim Hosp, Bunteweg 9, D-30559 Hannover, Germany
[2] Univ Nacl Colombia, Fac Vet Med, Small Anim Clin, Bogota, Colombia
[3] Hannover Med Sch, Dept Orthopaed Surg, Hannover, Germany
[4] Leibniz Univ Hannover, Inst Forming Technol & Machines, Hannover, Germany
来源
BMC VETERINARY RESEARCH | 2017年 / 13卷
关键词
Bone mineral density; DEXA; Digital radiography; Canine; Femur; Bone remodelling; TOTAL HIP-REPLACEMENT; RETROSPECTIVE EVALUATION; ARTHROPLASTY; DOGS; COMPLICATIONS; PRECISION;
D O I
10.1186/s12917-017-1047-y
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Aseptic loosening due to bone remodelling processes after total hip replacement is one common cause for revision surgery. In human medicine, dual-energy X-ray absorptiometry (DEXA) is the gold standard for quantitative evaluation of bone mineral density, whereas in veterinary medicine conventional radiography is used for follow-up studies. Recently, a method has been described using digital X-ray images for quantitative assessment of grey scale values of bone contrast. Therefore, the aim of the present study was to evaluate the correlation of bone mineral density (BMD) measured by DEXA with grey scale values (GV) measured in digital X-ray images (RX50, RX66) ex vivo. Results: The measured GV in the chosen X-ray settings showed on average a good correlation (r = 0.61) to the measured BMD with DEXA. Correlation between the two X-ray settings was very good (r = 0.81). For comparisons among regions of interests (ROIs) a difference of 8.2% was found to be statistically significant, whereas in the case of RX50 and RX66 differences of 5.3% and 4.1% were found to be statistically significant. Conclusions: Results indicate that measuring absolute changes in bone mineral density might be possible using digital radiography. Not all significant differences between ROIs detectable with DEXA can be displayed in the X-ray images because of the lower sensitivity of the radiographs. However, direct comparison of grey scale values of the periprosthetic femur in one individual patient during the follow-up period, in order to predict bone remodelling processes, should be possible, but with a lesser sensitivity than with DEXA. It is important that the same X-ray settings are chosen for each patient for follow-up studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Precision of Bone Mineral Density Measurements Around Total Ankle Replacement Using Dual Energy X-ray Absorptiometry
    Messina, Carmelo
    Usuelli, Federico Giuseppe
    Maccario, Camilla
    Di Silvestri, Claudia Angela
    Gitto, Salvatore
    Cortese, Maria Cristina
    Albano, Domenico
    Sconfienza, Luca Maria
    JOURNAL OF CLINICAL DENSITOMETRY, 2020, 23 (04) : 656 - 663
  • [42] Dual-energy X-ray absorptiometry underestimates in vivo lumbar spine bone mineral density in overweight rats
    Cherif, Rim
    Vico, Laurence
    Laroche, Norbert
    Sakly, Mohsen
    Attia, Nebil
    Lavet, Cedric
    JOURNAL OF BONE AND MINERAL METABOLISM, 2018, 36 (01) : 31 - 39
  • [43] In vivo differences among scan modes in bone mineral density measurement at dual-energy X-ray absorptiometry
    Bandirali, Michele
    Sconfienza, Luca M.
    Aliprandi, Alberto
    Di Leo, Giovanni
    Marchelli, Daniele
    Ulivieri, Fabio M.
    Sardanelli, Francesco
    RADIOLOGIA MEDICA, 2014, 119 (04): : 257 - 260
  • [44] Relationship between bone strength and dual-energy X-ray absorptiometry measurements in pigs
    Nielsen, D. H.
    McEvoy, F. J.
    Madsen, M. T.
    Jensen, J. B.
    Svalastoga, E.
    JOURNAL OF ANIMAL SCIENCE, 2007, 85 (03) : 667 - 672
  • [45] Discordance in lumbar bone mineral density measurements by quantitative computed tomography and dual-energy X-ray absorptiometry in postmenopausal women: a prospective comparative study
    Lin, Wentao
    He, Chaoqin
    Xie, Faqin
    Chen, Tao
    Zheng, Guanghao
    Yin, Houjie
    Chen, Haixiong
    Wang, Zhiyun
    SPINE JOURNAL, 2023, 23 (02) : 295 - 304
  • [46] Dual-energy X-ray absorptiometry applied to the assessment of tibial subchondral bone mineral density in osteoarthritis of the knee
    S. Clarke
    C. Wakeley
    J. Duddy
    M. Sharif
    I. Watt
    K. Ellingham
    C. J. Elson
    G. Nickols
    J. R. Kirwan
    Skeletal Radiology, 2004, 33 : 588 - 595
  • [47] Assessment of bone mineral density by dual energy x-ray absorptiometry in patients with mucopolysaccharidoses
    Hsiang-Yu Lin
    Shou-Chuan Shih
    Chih-Kuang Chuang
    Ming-Ren Chen
    Dau-Ming Niu
    Shuan-Pei Lin
    Orphanet Journal of Rare Diseases, 8
  • [48] Effects of radioisotopes on the accuracy of dual-energy X-ray absorptiometry for bone densitometry
    Mueller, B
    O'Connor, MK
    JOURNAL OF CLINICAL DENSITOMETRY, 2002, 5 (03) : 283 - 287
  • [49] Bone Mineral Analysis through Dual Energy X-Ray Absorptiometry in Laboratory Animals
    Tsujio, Masashi
    Mizorogi, Toshihiro
    Kitamura, Itsuko
    Maeda, Yasuhiro
    Nishijima, Kazutoshi
    Kuwahara, Sachi
    Ohno, Tamio
    Niida, Shunpei
    Nagaya, Masahiro
    Saito, Ryoichi
    Tanaka, Shin
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2009, 71 (11) : 1493 - 1497
  • [50] Effect of 18F-FDG Administration on Measurements of Bone Mineral Density and Body Composition by Dual-Energy X-ray Absorptiometry
    Kim, Dae-Weung
    Kim, Woo Hyoung
    Kim, Myoung Hyoun
    Kim, Seong Su
    Mo, Eun Hee
    Lee, Chun Ho
    Kim, Chang Guhn
    JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (03) : 283 - 286