Comparative measurements of bone mineral density and bone contrast values in canine femora using dual-energy X-ray absorptiometry and conventional digital radiography

被引:7
|
作者
Lucas, K. [1 ]
Nolte, I. [1 ]
Galindo-Zamora, V. [2 ]
Lerch, M. [3 ]
Stukenborg-Colsman, C. [3 ]
Behrens, B. A. [4 ]
Bouguecha, A. [4 ]
Betancur, S. [4 ]
Almohallami, A. [4 ]
Wefstaedt, P. [1 ]
机构
[1] Univ Vet Med Hannover, Small Anim Hosp, Bunteweg 9, D-30559 Hannover, Germany
[2] Univ Nacl Colombia, Fac Vet Med, Small Anim Clin, Bogota, Colombia
[3] Hannover Med Sch, Dept Orthopaed Surg, Hannover, Germany
[4] Leibniz Univ Hannover, Inst Forming Technol & Machines, Hannover, Germany
来源
BMC VETERINARY RESEARCH | 2017年 / 13卷
关键词
Bone mineral density; DEXA; Digital radiography; Canine; Femur; Bone remodelling; TOTAL HIP-REPLACEMENT; RETROSPECTIVE EVALUATION; ARTHROPLASTY; DOGS; COMPLICATIONS; PRECISION;
D O I
10.1186/s12917-017-1047-y
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Aseptic loosening due to bone remodelling processes after total hip replacement is one common cause for revision surgery. In human medicine, dual-energy X-ray absorptiometry (DEXA) is the gold standard for quantitative evaluation of bone mineral density, whereas in veterinary medicine conventional radiography is used for follow-up studies. Recently, a method has been described using digital X-ray images for quantitative assessment of grey scale values of bone contrast. Therefore, the aim of the present study was to evaluate the correlation of bone mineral density (BMD) measured by DEXA with grey scale values (GV) measured in digital X-ray images (RX50, RX66) ex vivo. Results: The measured GV in the chosen X-ray settings showed on average a good correlation (r = 0.61) to the measured BMD with DEXA. Correlation between the two X-ray settings was very good (r = 0.81). For comparisons among regions of interests (ROIs) a difference of 8.2% was found to be statistically significant, whereas in the case of RX50 and RX66 differences of 5.3% and 4.1% were found to be statistically significant. Conclusions: Results indicate that measuring absolute changes in bone mineral density might be possible using digital radiography. Not all significant differences between ROIs detectable with DEXA can be displayed in the X-ray images because of the lower sensitivity of the radiographs. However, direct comparison of grey scale values of the periprosthetic femur in one individual patient during the follow-up period, in order to predict bone remodelling processes, should be possible, but with a lesser sensitivity than with DEXA. It is important that the same X-ray settings are chosen for each patient for follow-up studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Reliability of analysis of the bone mineral density of the second and fifth metatarsals using dual-energy x-ray absorptiometry (DXA)
    Pritchard, N. Stewart
    Smoliga, James M.
    Anh-Dung Nguyen
    Branscomb, Micah C.
    Sinacore, David R.
    Taylor, Jeffrey B.
    Ford, Kevin R.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2017, 10
  • [32] Accuracy and precision of bone mineral density and bone mineral content in excised rat humeri using fan beam dual-energy X-ray absorptiometry
    Kastl, S
    Sommer, T
    Klein, P
    Hohenberger, W
    Engelke, K
    BONE, 2002, 30 (01) : 243 - 246
  • [33] Reliability of analysis of the bone mineral density of the second and fifth metatarsals using dual-energy x-ray absorptiometry (DXA)
    N. Stewart Pritchard
    James M. Smoliga
    Anh-Dung Nguyen
    Micah C. Branscomb
    David R. Sinacore
    Jeffrey B. Taylor
    Kevin R. Ford
    Journal of Foot and Ankle Research, 10
  • [34] Comparison of Differences in Bone Mineral Density Measurement With 3 Hologic Dual-Energy X-Ray Absorptiometry Scan Modes
    Yu, Wei
    Zhang, Zaizhu
    Pan, Wei
    Guan, Wenmin
    Lin, Qiang
    Xia, Weibo
    Li, Taisheng
    Hsieh, Evelyn
    JOURNAL OF CLINICAL DENSITOMETRY, 2021, 24 (04) : 645 - 650
  • [35] THE BONE-MINERAL DENSITY CHANGE WITH AGING OF JAPANESE WOMEN MEASURED BY SINGLE-ENERGY X-RAY ABSORPTIOMETRY AND DUAL-ENERGY X-RAY ABSORPTIOMETRY
    HOSHI, K
    YAMADA, H
    TSUKIKAWA, S
    SUGANO, T
    ENDO, C
    SATO, A
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 1993, 253 (02) : 65 - 69
  • [36] Osteoporosis after gastrectomy: bone mineral density of lumbar spine assessed by dual-energy X-ray absorptiometry
    Adachi, Y
    Shiota, E
    Matsumata, T
    Iso, Y
    Yoh, R
    Kitano, S
    CALCIFIED TISSUE INTERNATIONAL, 2000, 66 (02) : 119 - 122
  • [37] Dual-energy X-ray absorptiometry underestimates in vivo lumbar spine bone mineral density in overweight rats
    Rim Cherif
    Laurence Vico
    Norbert Laroche
    Mohsen Sakly
    Nebil Attia
    Cedric Lavet
    Journal of Bone and Mineral Metabolism, 2018, 36 : 31 - 39
  • [38] MEASUREMENT OF LUMBAR SPINAL BONE-MINERAL DENSITY IN PRETERM INFANTS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TSUKAHARA, H
    SUDO, M
    UMEZAKI, M
    FUJII, Y
    KURIYAMA, M
    YAMAMOTO, K
    ISHII, Y
    BIOLOGY OF THE NEONATE, 1993, 64 (2-3): : 96 - 103
  • [39] Dual-energy X-ray absorptiometry applied to the assessment of tibial subchondral bone mineral density in osteoarthritis of the knee
    Clarke, S
    Wakeley, C
    Duddy, J
    Sharif, M
    Watt, I
    Ellingham, K
    Elson, CJ
    Nickols, G
    Kirwan, JR
    SKELETAL RADIOLOGY, 2004, 33 (10) : 588 - 595
  • [40] Effect of pregnancy, lactation and weaning on bone mineral density in rats as determined by dual-energy X-ray absorptiometry
    Nishiwaki, M
    Yasumizu, T
    Hoshi, K
    Ushijima, H
    ENDOCRINE JOURNAL, 1999, 46 (05) : 711 - 716