Comparison of conventional time-intensity curves vs. maximum intensity over time for post-processing of dynamic contrast-enhanced ultrasound

被引:39
作者
Palmowski, Moritz [1 ,2 ]
Lederle, Wiltrud [2 ]
Gaetjens, Jessica [2 ]
Socher, Michaela [3 ]
Hauff, Peter [4 ]
Bzyl, Jessica [2 ]
Semmler, Wolfhard [3 ]
Guenther, Rolf W. [1 ]
Kiessling, Fabian [2 ]
机构
[1] Rhein Westfal TH Aachen, Fac Med, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Fac Med, Inst Expt Mol Imaging, D-52074 Aachen, Germany
[3] German Canc Res Ctr, D-6900 Heidelberg, Germany
[4] Bayer Schering Pharma AG, Global Drug Discovery, Berlin, Germany
关键词
Dynamic contrast-enhanced ultrasound; Post-processing; MIOT; Angiogenesis; Therapy monitoring; ANGIOGENESIS;
D O I
10.1016/j.ejrad.2009.10.030
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our aim was to prospectively compare two post-processing techniques for dynamic contrast-enhanced ultrasound and to evaluate their impact for monitoring antiangiogenic therapy. Thus, mice with epidermoid carcinoma xenografts were examined during administration of polybutylcyanoacrylate-microbubbles using a small animal ultrasound system (40 MHz). Cine loops were acquired and analyzed using time-intensity (TI) and maximum intensity over time (MIOT) curves. Influences of fast (50 mu l/2 s) vs. slow (50 mu l/10 s) injection of microbubbles on both types of curves were investigated. Sensitivities of both methods for assessing effects of antiangiogenic treatment (SU11248) were examined. Correlative histological analysis was performed for vessel-density. Mann-Whitney test was used for statistical analysis. Microbubble injection rates significantly influenced upslope, time-to-peak and peak enhancement of conventional TI curves (p < 0.05) but had almost no impact on maximum enhancement of MIOT curves (representing relative blood volume). Additionally, maximum enhancement of MIOT curves captured antiangiogenic therapy effects more reliably and earlier (already after 1 day of therapy; p < 0.05) than peak enhancement of TI curves. Immunohistochemistry validated the significantly (p < 0.01) lower vessel densities in treated tumors and high correlation (R-2 = 0.95) between vessel-density and maximum enhancement of MIOT curves was observed. In conclusion, MIOT is less susceptible to variations of the injection's speed. It enables to assess changes of the relative blood volume earlier and with lower standard deviations than conventional TI curves. It can easily be translated into clinical practice and thus may provide a promising tool for cancer therapy monitoring. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E149 / E153
页数:5
相关论文
共 21 条
  • [1] Functional imaging in CT
    Dawson, Peter
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) : 331 - 340
  • [2] Quantitative analysis of contrast enhancement
    Derchi, LE
    Martinoli, C
    Pretolesi, F
    Crespi, G
    Buccicardi, D
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) : S372 - S376
  • [3] Comments and Illustrations Regarding the Guidelines and Good Clinical Practice Recommendations for Contrast-Enhanced Ultrasound (CEUS) - Update 2008
    Dietrich, C. F.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2008, 29 : S188 - S202
  • [4] Evelhoch JL, 1999, JMRI-J MAGN RESON IM, V10, P254, DOI 10.1002/(SICI)1522-2586(199909)10:3<254::AID-JMRI5>3.0.CO
  • [5] 2-9
  • [6] Sonographic depiction of microvessel perfusion - Principles and potential
    Fleischer, AC
    Niermann, KJ
    Donnelly, EF
    Yankeelov, TE
    Canniff, KM
    Hallahan, DE
    Rothenberg, ME
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (11) : 1499 - 1506
  • [7] How to assess anti-tumour efficacy by imaging techniques
    Gwyther, Stephen J.
    Schwartz, Lawrence H.
    [J]. EUROPEAN JOURNAL OF CANCER, 2008, 44 (01) : 39 - 45
  • [8] Comparing dynamic parameters of tumor vascularization in nude mice revealed by magnetic resonance imaging and contrast-enhanced intermittent power Doppler sonography
    Kiessling, F
    Krix, M
    Heilmann, M
    Vosseler, S
    Lichy, M
    Fink, C
    Farhan, N
    Kleinschmidt, K
    Schad, L
    Fusenig, NE
    Delorme, S
    [J]. INVESTIGATIVE RADIOLOGY, 2003, 38 (08) : 516 - 524
  • [9] Non-invasive assessment of vessel morphology and function in tumors by magnetic resonance imaging
    Kiessling, Fabian
    Jugold, Manfred
    Woenne, Eva C.
    Brix, Gunnar
    [J]. EUROPEAN RADIOLOGY, 2007, 17 (08) : 2136 - 2148
  • [10] Analysis of first-pass bolus geometry in contrast-enhanced MRA of thoracic vessels
    Kreitner, KF
    Kunz, RP
    Weschler, C
    Ley, S
    Krummenauer, F
    Schreiber, WG
    Thelen, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (05): : 646 - 654