Tissue-mimicking bladder wall phantoms for evaluating acoustic radiation force-optical coherence elastography systems

被引:13
作者
Ejofodomi, O'tega A. [1 ]
Zderic, Vesna [1 ]
Zara, Jason M. [1 ]
机构
[1] George Washington Univ, Dept Elect & Comp Engn, Washington, DC 20052 USA
关键词
acoustic tomography; biological tissues; biomechanics; biomedical materials; biomedical optical imaging; biomedical ultrasonics; optical tomography; phantoms; REMOTE PALPATION; SPEED; ATTENUATION;
D O I
10.1118/1.3352686
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Acoustic radiation force-optical coherence elastography (ARF-OCE) systems are novel imaging systems that have the potential to simultaneously quantify and characterize the optical and mechanical properties of in vivo tissues. This article presents the construction of bladder wall phantoms for use in ARF-OCE systems. Mechanical, acoustic, and optical properties are reported and compared to published values for the urinary bladder. Methods: The phantom consisted of 0.2000 +/- 0.0089 and 6.0000 +/- 0.2830 mu m polystyrene microspheres (Polysciences Inc., Warrington, PA, Catalog Nos. 07304 and 07312), 7.5 +/- 1.5 mu m copolymer microspheres composed of acrylonitrile and vinylidene chloride, (Expancel, Duluth, GA, Catalog No. 461 DU 20), and bovine serum albumin within a gelatin matrix. Young's modulus was measured by successive compression of the phantom and obtaining the slope of the resulting force-displacement data. Acoustic measurements were performed using the transmission method. The phantoms were submerged in a water bath and placed between transmitting and receiving 13 mm diameter unfocused transducers operating at a frequency of 3.5 MHz. A MATLAB algorithm to extract the optical scattering coefficient from optical coherence tomography (OCT) images of the phantom was used. Results: The phantoms possess a Young's modulus of 17.12 +/- 2.72 kPa, a mass density of 1.05 +/- 0.02 g/cm(3), an acoustic attenuation coefficient of 0.66 +/- 0.08 dB/cm/ MHz, a speed of sound of 1591 +/- 8.76 m/s, and an optical scattering coefficient of 1.80 +/- 0.23 mm(-1). Ultrasound and OCT images of the bladder wall phantom are presented. Conclusions: A material that mimics the mechanical, optical, and acoustic properties of healthy bladder wall has been developed. This tissue-mimicking bladder wall phantom was developed as a control tool to investigate the feasibility of using ARF-OCE to detect the mechanical and optical changes that may be indicative of the onset or development of cancer in the urinary bladder. By following the methods used in this article, phantoms matching the optical, acoustic, and mechanical properties of other biological tissues can also be constructed.
引用
收藏
页码:1440 / 1448
页数:9
相关论文
共 40 条
  • [31] Optical coherence tomographic elastography technique for measuring deformation and strain of atherosclerotic tissues
    Rogowska, J
    Patel, NA
    Fujimoto, JG
    Brezinski, ME
    [J]. HEART, 2004, 90 (05) : 556 - 562
  • [32] Elastic moduli of normal and pathological human breast tissues: an inversion-technique-based investigation of 169 samples
    Samani, Abbas
    Zubovits, Judit
    Plewes, Donald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (06) : 1565 - 1576
  • [33] Speckle in optical coherence tomography
    Schmitt, JM
    Xiang, SH
    Yung, KM
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 95 - 105
  • [34] OCT elastography: imaging microscopic deformation and strain of tissue
    Schmitt, JM
    [J]. OPTICS EXPRESS, 1998, 3 (06): : 199 - 211
  • [35] SOEST G, 2007, P SPIE, V6627
  • [36] Measurement of bone mineral density via light scattering
    Ugryumova, N
    Matcher, SJ
    Attenburrow, DP
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (03) : 469 - 483
  • [37] A method of imaging viscoelastic parameters with acoustic radiation force
    Walker, WF
    Fernandez, FJ
    Negron, LA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) : 1437 - 1447
  • [38] WALKER WF, 2002, IEEE T ULTRASON FERR, V49, P1543
  • [39] Tissue Doppler optical coherence elastography for real time strain rate and strain mapping of soft tissue
    Wang, Ruikang K.
    Ma, Zhenhe
    Kirkpatrick, Sean J.
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (14)
  • [40] High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength
    Yun, SH
    Tearney, GJ
    Bouma, BE
    Park, BH
    de Boer, JF
    [J]. OPTICS EXPRESS, 2003, 11 (26): : 3598 - 3604