Multi-exposure laser speckle contrast imaging using a video-rate multi-tap charge modulation image sensor

被引:4
作者
Sivakumar, Panneer Selvam [1 ]
Kagawa, Keiichiro [2 ]
Crouzet, Christian [3 ]
Choi, Bernard [3 ,4 ,5 ]
Yasutomi, Keita [2 ]
Kawahito, Shoji [2 ]
机构
[1] Shizuoka Univ, Grad Sch Sci & Technol, 3-5-1 Johoku, Hamamatsu, Shizuoka 4328011, Japan
[2] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku, Hamamatsu, Shizuoka 4328011, Japan
[3] Univ Calif Irvine, Beckman Laser Inst & Med Clin, 1002 Hlth Sci Rd, Irvine, CA 92612 USA
[4] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[5] Univ Calif Irvine, Dept Surg, Irvine, CA 92697 USA
来源
OPTICS EXPRESS | 2019年 / 27卷 / 18期
基金
日本学术振兴会; 美国国家卫生研究院;
关键词
SPEED;
D O I
10.1364/OE.27.026175
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Multi-exposure laser speckle contrast imaging (MELSCI) systems based on high frame rate cameras are suitable for wide-field quantitative measurement of blood flow. However, high-speed camera-based MELSCI requires high power consumption, large memory, and high processing capability, which may lead to relatively large and expensive hardware. To realize a compact and cost-efficient MELSCI system, we discuss an application of the multi-tap CMOS image sensor originally designed for time-of-flight range imaging. This image sensor operated in the global shutter mode and every pixel was provided with multiple charge-storage diodes. Multiple images for different exposures were acquired simultaneously because exposure patterns were programmable to implement an arbitrary exposure duration for each tap. The frame rate was close to video frame rates (30 frames per second (fps)) regardless of the exposure pattern. The feasibility of the proposed method was verified by simulations that were performed with real speckle images captured by a high-speed camera at 40 kfps. Experiments with a four-tap CMOS image sensor demonstrated that a flow speed map was obtained at a moderate frame rate such as 35 fps for a moving ground glass plate and 45 fps for flowing Intralipose, which were linearly moved at speeds of 1-5 mm/s. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing
引用
收藏
页码:26175 / 26191
页数:17
相关论文
共 33 条
  • [1] Bamji CS, 2018, ISSCC DIG TECH PAP I, P94, DOI 10.1109/ISSCC.2018.8310200
  • [2] Briers J D, 1996, J Biomed Opt, V1, P174, DOI 10.1117/12.231359
  • [3] Simplified laser-speckle-imaging analysis method and its application to retinal blood flow imaging
    Cheng, Haiying
    Duong, Timothy Q.
    [J]. OPTICS LETTERS, 2007, 32 (15) : 2188 - 2190
  • [4] Linear response range characterization and in vivo application of laser speckle imaging of blood flow dynamics
    Choi, Bernard
    Ramirez-San-Juan, Julio C.
    Lotfi, Justin
    Nelson, J. Stuart
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)
  • [5] High-speed multi-exposure laser speckle contrast imaging with a single-photon counting camera
    Dragojevic, Tanja
    Bronzi, Danilo
    Varma, Hari M.
    Valdes, Claudia P.
    Castellvi, Clara
    Villa, Federica
    Tosi, Alberto
    Justicia, Carles
    Zappa, Franco
    Durduran, Turgut
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (08): : 2865 - 2876
  • [6] Review of laser speckle contrast techniques for visualizing tissue perfusion
    Draijer, Matthijs
    Hondebrink, Erwin
    van Leeuwen, Ton
    Steenbergen, Wiendelt
    [J]. LASERS IN MEDICAL SCIENCE, 2009, 24 (04) : 639 - 651
  • [7] Can laser speckle flowmetry be made a quantitative tool?
    Duncan, Donald D.
    Kirkpatrick, Sean J.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (08) : 2088 - 2094
  • [8] A laser speckle imaging technique for measuring tissue perfusion
    Forrester, KR
    Tulip, J
    Leonard, C
    Stewart, C
    Bray, RC
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (11) : 2074 - 2084
  • [9] A Time-of-Flight Range Image Sensor With Background Canceling Lock-in Pixels Based on Lateral Electric Field Charge Modulation
    Han, Sang-Man
    Takasawa, Taishi
    Yasutomi, Keita
    Aoyama, Satoshi
    Kagawa, Keiichiro
    Kawahito, Shoji
    [J]. IEEE JOURNAL OF THE ELECTRON DEVICES SOCIETY, 2015, 3 (03): : 267 - 275
  • [10] A 15.6 frames per second 1-megapixel multiple exposure laser speckle contrast imaging setup
    Hultman, Martin
    Fredriksson, Ingemar
    Larsson, Marcus
    Alvandpour, Atila
    Stromberg, Tomas
    [J]. JOURNAL OF BIOPHOTONICS, 2018, 11 (02)