Electrocatalytic reduction of nitrite and bromate and their highly sensitive determination on carbon paste electrode modified with new copper Schiff base complex

被引:30
|
作者
Ourari, Ali [1 ]
Ketfi, Bouzid [1 ]
Malha, Seif Islam Rabie [1 ]
Amine, Aziz [2 ]
机构
[1] Univ Setif 1 Setif, Fac Technol, LEIMCR, Route Bejaia, Setif 19000, Algeria
[2] Hassan II Univ Casablanca, Fac Sci & Tech, BP 146, Mohammadia 20650, Morocco
关键词
Carbon paste electrode; Copper Schiff base complex; DPV; Amperometry; Nitrite; Bromate; STRIPPING VOLTAMMETRIC DETERMINATION; SELECTIVE DETERMINATION; ELECTROCHEMICAL SENSOR; OXIDATION; FILM; CU(II); CONSTRUCTION; HYDRAZINE; NITRATE; CELLS;
D O I
10.1016/j.jelechem.2017.04.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A modified carbon paste electrode by Cu-II-(N,N'-bis(2,5-dihydroxybenzylidene)-1,2-diaminoethane) (Cu-II-DHB) as a new synthesized copper Schiff base complex. This modified electrode (ME) was constructed for the simultaneous determination of nitrite and bromate using amperometry and differential pulse voltammetry (DPV). The electrochemical characterization and electro-catalyst of NO2- and BrO3- were thoroughly investigated by cyclic voltammetry (CV). The treatment of the voltammetric results showed that it was a purely diffusion-controlled process involving one-electron in the rate-determining step. The mechanism for the interaction of nitrite with [Cu-II-DHB] Schiff base complex involving the (Cu-II/Cu-I) redox system. This new ME showed a good and efficient electro-catalytic activity towards the cathodic reduction of nitrite and bromate. The resulting DPV response indicates that [Cu-II-DHB]-CPE can be advantageously used to determine nitrite concentration in a linear range of 2-14 nM (R-2 = 0.992) with a detection limit of 1.5 nM. The amperometric result reveals that [Cu-II-DHB]-CPE is also an effective material for bromate detection with a detection limit of 10 nM.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [1] Sensitive Determination of Copper on New Modified Glassy Carbon Paste Electrode
    Skrivanj, Sandra
    Stankovic, Dalibor M.
    Khan, Muslim
    Nikolic, Aleksandar S.
    Vulic, Predrag
    Manojlovic, Dragan D.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (02): : 230 - 241
  • [2] Electrocatalytic determination of sumatriptan on the surface of carbon-paste electrode modified with a composite of cobalt/Schiff-base complex and carbon nanotube
    Amiri, Mandana
    Pakdel, Zohreh
    Bezaatpour, Abolfazi
    Shahrokhian, Saeed
    BIOELECTROCHEMISTRY, 2011, 81 (02) : 81 - 85
  • [3] Voltammetric determination of methimazole using a carbon paste electrode modified with a Schiff base complex of cobalt
    Shahrokhian, Saeed
    Ghalkhani, Masoumeh
    ELECTROANALYSIS, 2008, 20 (10) : 1061 - 1066
  • [4] Highly sensitive carbon paste electrode modified with a synthesized ferrocenyl Schiff base for trace determination of Ce(III) in real samples
    Arabhalvaei, Nastaran
    Soleymanpour, Ahmad
    Shafaatian, Bita
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2022, 69 (02) : 339 - 348
  • [5] Electrocatalytic reduction of Dioxygen at carbon paste electrode modified with a novel cobalt(III) schiffs base complex
    Shamsipur, Mojtaba
    Najafi, Mostafa
    Hosseini, Mohammad-Reza Milani
    Sharghi, Hashem
    ELECTROANALYSIS, 2007, 19 (16) : 1661 - 1667
  • [6] Electrocatalytic Oxidation of Sulfite and its Highly Sensitive Determination on Graphite Screen Printed Electrode Modified with New Schiff base Compound
    Maaref, Hamed
    Foroughi, Mohammad Mehdi
    Sheikhhosseini, Enayatollah
    Akhgar, Mohammad Reza
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (08): : 1080 - 1092
  • [7] Electrocatalytic oxidation of hydrazine at a cobalt(II) Schiff-base-modified carbon paste electrode
    Kamyabi, Mohammad Ali
    Shahabi, Shirin
    Hosseini-Monfared, Hassan
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2008, 155 (01) : F8 - F12
  • [8] Voltammetric determination of copper in water samples using a Schiff base/carbon nanotube-modified carbon paste electrode
    Izadkhah, V.
    Farmany, A.
    Mortazavi, S. S.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 21 : 994 - 996
  • [9] Highly Sensitive Electrocatalytic Determination of Formaldehyde Using a Ni/Ionic Liquid Modified Carbon Nanotube Paste Electrode
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Ahmadi, Farideh
    BULLETIN OF CHEMICAL REACTION ENGINEERING AND CATALYSIS, 2018, 13 (03): : 529 - 542
  • [10] Poly(ortho-toluidine) modified for electrocatalytic reduction carbon paste electrode:: A sensor of nitrite
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Zarei, Ebrahim
    ELECTROANALYSIS, 2008, 20 (04) : 379 - 385