Numerical Simulation of the non-Newtonian blood flow through aortic Bileaflet mechanical heart valve using Fluid-Structure Interaction approach

被引:5
作者
Abbas, Syed Samar [1 ]
Nasif, Mohammad Shakir [1 ]
Said, Mior Azman Meor [1 ]
Al-Waked, Rafat [2 ]
机构
[1] Univ Teknol PETRONAS, Dept Engn Mech, Seri Iskandar 32610, Perak, Malaysia
[2] German Jordanian Univ, Sch Appl Tech Sci, Mech & Maintenance Engn Dept, Amman 11180, Jordan
来源
6TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY 2018: WORLD ENGINEERING SCIENCE & TECHNOLOGY CONGRESS (ESTCON) | 2018年 / 2035卷
关键词
ROOT; GEOMETRY;
D O I
10.1063/1.5075593
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Numerical simulation of blood flowing through Bileaflet Mechanical Heart valves (BMHV) has been widely performed in the past to achieve the unprecedented details of the cardiac mechanics of BMHV and the associated blood flow field. However, most of the past studies have assumed the blood to be Newtonian fluid. Although in large arteries like aorta, blood behaves as a Newtonian fluid, however its Non-Newtonian effects can become important as it passes through regions with low shear rates. This paper has modelled blood as a non-Newtonian incompressible fluid and complete physiological cardiac cycle has been simulated. Arbitrary Lagrangian Eulerian approach has been employed to establish blood-leaflet interaction. The results indicated a 58% higher average wall shear stress on the fully closed leaflets when modelling blood as non-Newtonian fluid compared to Newtonian modelling. Therefore, the paper concludes that the blood must be modelled as non-Newtonian fluid to achieve accurate hemodynamics.
引用
收藏
页数:10
相关论文
共 18 条
[1]   Numerical investigation on effect of aortic root geometry on flow induced structural stresses developed in a bileaflet mechanical heart valve [J].
Abbas, S. S. ;
Nasif, M. S. ;
Said, M. A. M. ;
Kadhim, S. K. .
INTERNATIONAL CONFERENCE ON APPLICATIONS AND DESIGN IN MECHANICAL ENGINEERING (ICADME 2017), 2017, 908
[2]   Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing [J].
Abbas, Syed Samar ;
Nasif, Mohammad Shakir ;
Said, Mior Azman Meor ;
Al-Waked, Rafat ;
Kadhim, Saleem Khalefa .
UTP-UMP SYMPOSIUM ON ENERGY SYSTEMS 2017 (SES 2017), 2017, 131
[3]   Flow-induced platelet activation and damage accumulation in a mechanical heart valve: Numerical studies [J].
Alemu, Yared ;
Bluestein, Danny .
ARTIFICIAL ORGANS, 2007, 31 (09) :677-688
[4]   On the effect of aortic root geometry on the coronary entry-flow after a bileaflet mechanical heart valve implant: a numerical study [J].
de Tullio, M. D. ;
Pedrizzetti, G. ;
Verzicco, R. .
ACTA MECHANICA, 2011, 216 (1-4) :147-163
[5]   Numerical simulation of the non-Newtonian blood flow through a mechanical aortic valve [J].
De Vita, F. ;
de Tullio, M. D. ;
Verzicco, R. .
THEORETICAL AND COMPUTATIONAL FLUID DYNAMICS, 2016, 30 (1-2) :129-138
[6]   Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model [J].
Dumont, Kris ;
Vierendeels, Jan ;
Kaminsky, Rado ;
Van Nooten, Guido ;
Verdonck, Pascal ;
Bluestein, Danny .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (04) :558-565
[7]   The influence of the non-Newtonian properties of blood on the flow in large arteries: steady flow in a carotid bifurcation model [J].
Gijsen, FJH ;
van de Vosse, FN ;
Janssen, JD .
JOURNAL OF BIOMECHANICS, 1999, 32 (06) :601-608
[8]  
Hall JE, 2015, GUYTON HALL TXB MED
[9]  
Hanafizadeh P, 2016, ARTIFICIAL ORGANS, V40
[10]  
Kadhim SK, 2017, SIMULATION