Detection of explosives by positive corona discharge ion mobility spectrometry

被引:216
作者
Tabrizchi, Mahmoud [1 ]
ILbeigi, Vahideh [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Explosives; Ion mobility spectrometry; Pyrolysis; GAS-CHROMATOGRAPHY; IONIZATION SOURCE; PHOTOIONIZATION; SPECTROSCOPY; EXTRACTION;
D O I
10.1016/j.jhazmat.2009.11.087
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, thermal decomposition has been used to detect explosives by IMS in positive polarity. Explosives including Pentaerythritol Tetra nitrate (PETN), Cyclo-1,3,5-Trimethylene-2,4,6-Trinitramine (RDX), 2,4,6-Trinitrotoluene (TNT), 2,4-Dihydro-5-nitro-3H-1,2,4-triazol-3-one (NTO), 1,3,5.7-Tetranitro-1,3,5,7-tetrazocine (HMX), have been evaluated at temperatures between 150 and 250 degrees C in positive polarity in air. Explosives yield NOx which causes NO+ peak to increase. Additional peaks may be used to identify the type of explosive. The limit of detection for RDX, HMX, PETN, NTO, and TNT were obtained to be 1, 10, 40, 1000, and 1000 ng, respectively. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:692 / 696
页数:5
相关论文
共 32 条
  • [1] Development of a short pulsed corona discharge ionization source for ion mobility spectrometry
    An, YA
    Aliaga-Rossel, R
    Choi, P
    Gilles, JP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (08) : 1 - 6
  • [2] [Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
  • [3] Asbury GR, 2000, TALANTA, V50, P1291
  • [4] ION MOBILITY DETECTOR FOR GAS-CHROMATOGRAPHY WITH A DIRECT PHOTO-IONIZATION SOURCE
    BAIM, MA
    EATHERTON, RL
    HILL, HH
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (11) : 1761 - 1766
  • [5] Rapid multivariate curve resolution applied to identification of explosives by ion mobility spectrometry
    Buxton, TL
    Harrington, PD
    [J]. ANALYTICA CHIMICA ACTA, 2001, 434 (02) : 269 - 282
  • [6] Solid phase micro extraction coupled with on-column GC/ECD for the post-blast analysis of organic explosives
    Calderara, S
    Gardebas, D
    Martinez, F
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2003, 137 (01) : 6 - 12
  • [7] Carr T.W., 1984, Plasma Chromatography
  • [8] Ion mobility spectrometry: a review. Part 1. Structural analysis by mobility measurement
    Creaser, CS
    Griffiths, JR
    Bramwell, CJ
    Noreen, S
    Hill, CA
    Thomas, CLP
    [J]. ANALYST, 2004, 129 (11) : 984 - 994
  • [9] Detection of inorganic ions from water by electrospray ionization-ion mobility spectrometry
    Dion, HM
    Ackerman, LK
    Hill, HH
    [J]. TALANTA, 2002, 57 (06) : 1161 - 1171
  • [10] EICEMAN GA, 1991, CRIT REV ANAL CHEM, V22, P17