Repeatability of ocular wavefront measurement

被引:34
|
作者
Davies, N
Diaz-Santana, L
Lara-Saucedo, D
机构
[1] City Univ London, Dept Optometry & Visual Sci, Appl Vis Res Ctr, London EC1V 0HB, England
[2] Middlesex Hosp, Dept Ophthalmol, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Phys, London, England
关键词
wavefront; refractive surgery; Zernike polynomial; cornea; error; custom correction;
D O I
10.1097/00006324-200302000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the repeatability of measurements of ocular aberrations using wavefront sensing in a small group of observers and to assess the potential effect of measurement error on custom corneal correction due to this variability. Method A Shack-Hartmann wavefront sensor was used to measure the ocular wavefront in nine eyes. Head position was stabilized using a dental bite bar, and the pupil was centred using a cathode ray tube monitor and circular grating. Twenty Shack-Hartmann images were collected for each measurement. Each observer had three sets of measurements taken; the first and the second after careful alignment and the final after regrasping the bite bar in the same position as for the second measurement, but without pupil realignment. The modulation transfer functions for each set were calculated, and the effect of best-aligned custom treatments on the modulation transfer function was estimated. Results. There were highly statistically significant differences in a large number of Zernike modes between the three sets of measurements. The modulation transfer functions calculated for the residual wavefronts after aligned custom treatment were below the diffraction limit. The root mean square wavefront errors were consistently better for the residual wavefronts obtained using the realigned data than using data taken without pupil realignment. Conclusions. Sequential measurement of ocular aberrations shows statistically significant differences in a large number of Zernike modes. If aberrations determined by a single measurement are to be used in a custom correction, the resulting modulation transfer function is likely to remain below the diffraction limit. Pupil realignment is critical in reduction of the residual root mean square wavefront values to a minimum.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 50 条
  • [41] Wavefront measurement with synthesizing method
    Wang, C
    Han, CY
    Liu, CG
    Zhang, HY
    Liu, XM
    ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY 2000, 2000, 4231 : 569 - 572
  • [42] Issues of wavefront tilt measurement
    Bol'basova, L. A.
    Lukin, V. P.
    JOURNAL OF OPTICAL TECHNOLOGY, 2021, 88 (11) : 625 - 629
  • [43] PRECISION OPTICAL WAVEFRONT MEASUREMENT
    SCHAHAM, M
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 306 : 183 - 191
  • [44] Measurement uncertainty is not synonym of measurement repeatability or measurement reproducibility...
    Paul De Bièvre
    Accreditation and Quality Assurance, 2008, 13 : 61 - 62
  • [45] Evaluation of the repeatability of a swept-source ocular biometer for measuring ocular biometric parameters
    Teresa Ferrer-Blasco
    Alberto Domínguez-Vicent
    José J. Esteve-Taboada
    Miguel A. Aloy
    Jose E. Adsuara
    Robert Montés-Micó
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 343 - 349
  • [46] Evaluation of the repeatability of a swept-source ocular biometer for measuring ocular biometric parameters
    Ferrer-Blasco, Teresa
    Dominguez-Vicent, Alberto
    Esteve-Taboada, Jose J.
    Aloy, Miguel A.
    Adsuara, Jose E.
    Montes-Mico, Robert
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (02) : 343 - 349
  • [47] Corneal and wavefront irregularity maps for determination of ocular abnormality
    Neal, Daniel R.
    Xiong, Wei
    Farrer, Steve
    Raymond, Thomas D.
    Copland, James
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [48] A New Polynomial Decomposition Method for Ocular Wavefront Analysis
    Gatinel, Damien
    Malet, Jacques
    Dumas, Laurent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [49] Influence of age on ocular wavefront aberration changes with accommodation
    lida, Yoshihiko
    Shimizu, Kimiya
    Ito, Misae
    Suzuki, Masanobu
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (07) : 696 - 701
  • [50] The effect of lubricant eye drops on ocular wavefront aberrations
    Airiani, S
    Rozell, J
    Lee, SM
    Braunstein, RE
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (06) : 709 - 715