Repeatability of ocular wavefront measurement

被引:34
|
作者
Davies, N
Diaz-Santana, L
Lara-Saucedo, D
机构
[1] City Univ London, Dept Optometry & Visual Sci, Appl Vis Res Ctr, London EC1V 0HB, England
[2] Middlesex Hosp, Dept Ophthalmol, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Phys, London, England
关键词
wavefront; refractive surgery; Zernike polynomial; cornea; error; custom correction;
D O I
10.1097/00006324-200302000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the repeatability of measurements of ocular aberrations using wavefront sensing in a small group of observers and to assess the potential effect of measurement error on custom corneal correction due to this variability. Method A Shack-Hartmann wavefront sensor was used to measure the ocular wavefront in nine eyes. Head position was stabilized using a dental bite bar, and the pupil was centred using a cathode ray tube monitor and circular grating. Twenty Shack-Hartmann images were collected for each measurement. Each observer had three sets of measurements taken; the first and the second after careful alignment and the final after regrasping the bite bar in the same position as for the second measurement, but without pupil realignment. The modulation transfer functions for each set were calculated, and the effect of best-aligned custom treatments on the modulation transfer function was estimated. Results. There were highly statistically significant differences in a large number of Zernike modes between the three sets of measurements. The modulation transfer functions calculated for the residual wavefronts after aligned custom treatment were below the diffraction limit. The root mean square wavefront errors were consistently better for the residual wavefronts obtained using the realigned data than using data taken without pupil realignment. Conclusions. Sequential measurement of ocular aberrations shows statistically significant differences in a large number of Zernike modes. If aberrations determined by a single measurement are to be used in a custom correction, the resulting modulation transfer function is likely to remain below the diffraction limit. Pupil realignment is critical in reduction of the residual root mean square wavefront values to a minimum.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 50 条
  • [31] Measurement repeatability of corneal aberrations
    Gobbe, M
    Guillon, M
    Maissa, C
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (05) : S567 - S571
  • [32] Repeatability of intraoperative Hartmann-Shack wavefront sensing in cataract surgery
    Georgiev, Stefan
    Hirnschall, Nino
    Fisus, Andreea-Dana
    Ruiss, Manuel
    Hienert, Julius
    Leisser, Christoph
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (07): : 902 - 906
  • [33] Repeatability of visual acuity measurement
    Raasch, TW
    Bailey, IL
    Bullimore, MA
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (05) : 342 - 348
  • [34] Agreement and Repeatability of Noncycloplegic and Cycloplegic Wavefront-based Autorefraction in Children
    Rauscher, Franziska G.
    Lange, Heike
    Yahiaoui-Doktor, Maryam
    Tegetmeyer, Helmut
    Sterker, Ina
    Hinz, Andreas
    Wahl, Siegfried
    Wiedemann, Peter
    Ohlendorf, Arne
    Blendowske, Ralf
    OPTOMETRY AND VISION SCIENCE, 2019, 96 (11) : 879 - 889
  • [35] Repeatability of i.Profiler for measuring wavefront aberrations in healthy eyes
    Liao, Xuan
    Wang, Mei-Jie
    Tan, Qing-Qing
    Lan, Chang-Jun
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (08) : 2525 - 2531
  • [36] Repeatability of i.Profiler for measuring wavefront aberrations in healthy eyes
    Xuan Liao
    Mei-Jie Wang
    Qing-Qing Tan
    Chang-Jun Lan
    International Ophthalmology, 2022, 42 : 2525 - 2531
  • [37] Reliability of corneal and total wavefront aberration measurements with the SCHWIND corneal and ocular wavefront analyzers
    Holzer, Mike P.
    Sassenroth, Martin
    Auffarth, Gerd U.
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) : 917 - 920
  • [38] Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer
    Roncevic, Mirjana Bjelos
    Busic, Mladen
    Cima, Ivan
    Elabjer, Biljana Kuzmanovic
    Bosnar, Damir
    Miletic, Daliborka
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (01) : 83 - 87
  • [39] Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometer
    Mirjana Bjeloš Rončević
    Mladen Bušić
    Ivan Čima
    Biljana Kuzmanović Elabjer
    Damir Bosnar
    Daliborka Miletić
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 83 - 87
  • [40] Measurement of the wavefront of XUV sources
    Le Pape, S
    Zeitoun, P
    Hergot, JF
    Carré, B
    Dhez, P
    François, M
    Idir, M
    Merdji, H
    Ros, D
    Carillon, A
    Salières, P
    JOURNAL DE PHYSIQUE IV, 2001, 11 (PR2): : 533 - 536