COMPARATIVE ANALYSIS OF LATTICE-BASED ALL-PASS FILTER AND SECOND ORDER GENERALIZED INTEGRATOR AS ORTHOGONAL SYSTEM GENERATOR OF A PLL

被引:1
作者
Emilio Belandria, Luciano [1 ]
Alejandro Agudelo, Nancy [1 ]
Bergas-Jane, Joan [2 ]
机构
[1] Natl Expt Univ Tachira, Dept Elect Engn, San Cristobal 5001, Venezuela
[2] Univ Politecn Cataluna, Ctr Technol Innovat Stat Converters & Drives, Dept Elect Engn, Diagonal 647, Barcelona 08028, Spain
关键词
All-Pass Filter; Orthogonal Signal Generator; Phase-Locked Loop; Single-Phase PLL; Notch Filter; Second Order Generalized Integrator; PHASE-LOCKED-LOOP; REFERENCE FRAME PLL; DC OFFSET; POWER CONVERTERS; SYNCHRONIZATION;
D O I
10.15598/aeee.v19i1.4002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a steady-state comparison of two methods that generate an orthogonal voltage system for a single-phase Phase-Locked Loop (PLL) structure: a widely accepted one based on a Second Order Generalized Integrator (SOGI) and a new one based on a All-Pass Filter (APF) with Lattice structure. Both methods are very attractive because of their simple digital implementation, low computational load and good performance under harmonically distorted grid conditions and variable frequency, so they are a good alternative to other known methods. The paper derives and analyzes the full state space models of the two methods. It is shown that these two methods are equivalent in the most common operation conditions of distributed energy resources, although the APF structure is clearly better than the SOGI one because it maintains its orthogonal generation ability for any higher notch frequencies and any lower sampling frequencies. The comparative analysis were validated by simulation using MATLAB/Simulink and experimental results using a fixed-point DSP.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
[1]   MODELING AND ROBUST CONTROL OF A GRID CONNECTED DIRECT DRIVEN PMSG WIND TURBINE BY ADRC [J].
Aboudrar, Imad ;
El Hani, Soumia ;
Mediouni, Hamza ;
Aghmadi, Ahmed .
ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 16 (04) :402-413
[2]   Demodulation type single-phase PLL with DC offset rejection [J].
Ahmed, H. ;
Benbouzid, M. .
ELECTRONICS LETTERS, 2020, 56 (07) :344-346
[3]   On the Enhancement of Generalized Integrator-Based Adaptive Filter Dynamic Tuning Range [J].
Ahmed, Hafiz ;
Benbouzid, Mohamed .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (10) :7449-7457
[4]   Low-pass filtering or gain tuning free simple DC offset rejection technique for single and three-phase systems [J].
Ahmed, Hafiz ;
Biricik, Samet ;
Benbouzid, Mohamed .
ELECTRIC POWER SYSTEMS RESEARCH, 2020, 186
[5]   Frequency Adaptive Parameter Estimation of Unbalanced and Distorted Power Grid [J].
Ahmed, Hafiz ;
Benbouzid, Mohamed ;
Ahsan, Mominul ;
Albarbar, Alhussein ;
Shahjalal, Mohammad .
IEEE ACCESS, 2020, 8 :8512-8519
[6]   SIMPLIFIED SECOND-ORDER GENERALIZED INTEGRATOR - FREQUENCY-LOCKED LOOP [J].
Ahmed, Hafiz ;
Benbouzid, Mohamed .
ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 17 (04) :405-412
[7]   Multiple Nonlinear Harmonic Oscillator-Based Frequency Estimation for Distorted Grid Voltage [J].
Ahmed, Hafiz ;
Bierhoff, Michael ;
Benbouzid, Mohamed .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (06) :2817-2825
[8]  
[Anonymous], 2007, 2007 9 INT C EL POW
[9]   Probabilistic Optimal Reactive Power Planning in Distribution Systems With Renewable Resources in Grid-Connected and Islanded Modes [J].
Arefifar, Seyed Ali ;
Mohamed, Yasser Abdel-Rady I. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (11) :5830-5839
[10]   Energy Storage in Distribution System Planning and Operation: Current Status and Outstanding Challenges [J].
Awadallah, Mohamed A. ;
Venkatesh, Bala .
CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2019, 42 (01) :10-19