Freeze-Drying in Novel Container System: Characterization of Heat and Mass Transfer in Glass Syringes

被引:22
作者
Patel, Sajal M. [1 ]
Pikal, Michael J. [1 ]
机构
[1] Univ Connecticut, Dept Pharmaceut Sci, Sch Pharm, Storrs, CT 06269 USA
关键词
prefilled syringes; freeze-drying; heat and mass transfer; novel container systems; MANOMETRIC TEMPERATURE-MEASUREMENT; PRODUCT TEMPERATURE; PART I;
D O I
10.1002/jps.22086
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
This study is aimed at characterizing and understanding different modes of heat and mass transfer in glass syringes to develop a robust freeze-drying process. Two different holder systems were used to freeze-dry in syringes: an aluminum (Al) block and a plexiglass holder. The syringe heat transfer coefficient was characterized by a sublimation test using pure water. Mannitol and sucrose (5% w/v) were also freeze-dried, as model systems, in both the assemblies. Dry layer resistance was determined from manometric temperature measurement (MTM) and product temperature was measured using thermocouples, and was also determined from MTM. Further, freeze-drying process was also designed using Smart freeze-dryer to assess its application for freeze-drying in novel container systems. Heat and mass transfer in syringes were compared against the traditional container system (i.e., glass tubing vial). In the Al block, the heat transfer was via three modes: contact conduction, gas conduction, and radiation with gas conduction being the dominant mode of heat transfer. In the plexiglass holder, the heat transfer was mostly via radiation; convection was not involved. Also, MTM/Smart freeze-drying did work reasonably well for freeze-drying in syringes. When compared to tubing vials, product temperature decreases and hence drying time increases in syringes. (C) 2010 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 99:3188-3204, 2010
引用
收藏
页码:3188 / 3204
页数:17
相关论文
共 30 条
[1]  
COSTANTINO HR, 2004, BIOTECHNOL PHARM ASP, P2
[2]  
DEGRAZIO FL, 2005, GENET ENG BIOTECHNOL, V25, P21
[3]  
French D., 2005, AM PHARM REV, V8, P30
[4]  
GALY MG, 1993, METHOD PACKAGING FRE
[5]  
GRABENKORT RW, 2002, SYRINGE SYSTEMS LYOP
[6]  
HOLMAN JP, 1997, HEAT TRANSFER, P205
[7]   Experimental Study and Modeling of Freeze-Drying in Syringe Configuration. Part I: Freezing Step [J].
Hottot, A. ;
Andrieu, J. ;
Vessot, S. ;
Shalaev, E. ;
Gatlin, L. A. ;
Ricketts, S. .
DRYING TECHNOLOGY, 2009, 27 (01) :40-48
[8]   Experimental Study and Modeling of Freeze-Drying in Syringe Configuration. Part II: Mass and Heat Transfer Parameters and Sublimation End-Points [J].
Hottot, A. ;
Andrieu, J. ;
Hoang, V. ;
Shalaev, E. Y. ;
Gatlin, L. A. ;
Ricketts, S. .
DRYING TECHNOLOGY, 2009, 27 (01) :49-58
[9]  
Leuenberger H, 1956, paper no. 56-A-144
[10]  
Milton N, 1997, PDA J PHARM SCI TECH, V51, P7