Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC

被引:89
作者
Jokl, MV [1 ]
机构
[1] Tech Univ Prague, CZ-16629 Prague, Czech Republic
关键词
Carbon dioxide - Contamination - Indoor air pollution;
D O I
10.1016/S0360-1323(99)00042-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Two new units are proposed for the evaluation of indoor air quality using the decibel concept, which give a much better approximation of the human perception of odour intensity, compared to the CO(2) and TVOC concentration scales. the decicarbdiox and the decitvoc. On the Psyche-Physical Scale according to Yaglou, the weakest odour that can be detected by the human smell sensors is equal to 1 and corresponds to the lower limit of percentage dissatisfaction (PD) of 5.8% and is equivalent to (a) a CO(2) threshold concentration of 485 ppm - O dB (odour CO(2)) - dCd (decicarbdiox), and (b) a TVOC threshold concentration of 50 mu g/m(3) - O dB (odour TVOC) - O dTv (decitvoc). The upper limit is determined by the initial value of toxicity (a) CO(2) - 15,000 ppm - 134 dCd, and (b) TVOC - 25,000 mu g/m(3) - 135 dTv. It is supposed that optimal values corresponding to PD = 20%, admissible values to PD-30% for unadapted and adapted persons and that long-term tolerable values (determining SBS range) and short-term tolerable Values (beginning of toxic range) are stated as well. The same figures used to evaluate noise can be used to evaluate air quality, additionally the contribution of individual constituents (at present acoustic and odour) to the overall quality of the environment can be ascertained. The new units dCd and dTv can express an increase or decrease in air contamination, i.e. by using air cleaners, new building materials, etc. The proposed system of dCd and dTv is compatible with BSR/ASHRAE 62-1989 R which can be used to determine the required volume of fresh air for ventilation by an improved method which takes into account different levels of required indoor air quality. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:677 / 697
页数:21
相关论文
共 51 条
  • [1] [Anonymous], 1987, AIR QUAL GUID EUR
  • [2] BENCKO V, 1994, INDOOR ENVIRON, V3, P213, DOI 10.1177/1420326X9400300408
  • [3] BERGLUND B, 1982, ENVIRON INT, V8, P395
  • [4] BERGLUND B, 1988, P IND AMB AIR QUAL C, P355
  • [5] Broder I, 1993, VOLATILE ORGANIC COM, P595
  • [6] BROWN VM, 1993, VOC ENV, P241
  • [7] *BSR ASHRAE, 1989, 621989R BSR ASHRAE
  • [8] *COMM EUR COMM, 1992, 14449 EUR EN COMM EU
  • [9] CRUMP DR, 1997, INDOOR BUILT ENVIRON, V6, P45
  • [10] Dingle P, 1993, INDOOR ENVIRON, V2, P217