Protein blocking inhibits ambient degradation of self-assembled monolayers for affinity biosensing

被引:1
作者
Brightbill, Eleanor L. [1 ]
Gezahagne, Hilena F. [1 ]
Jin, Decarle S. [1 ]
Brown, Billyde [2 ]
Vogel, Eric M. [1 ]
机构
[1] Georgia Inst Technol, Sch Mat Sci & Engn, Atlanta, GA 30332 USA
[2] Georgia Tech Mfg Inst, 813 Ferst Dr NW, Atlanta, GA 30332 USA
基金
美国国家科学基金会; 美国食品与农业研究所;
关键词
Label-free affinity biosensing; Thiolate self-assembled monolayers; Oxidation; Degradation; Storage stability; Biosensor shelf life; QUARTZ-CRYSTAL MICROBALANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; SURFACE-PLASMON RESONANCE; CARBOXYLIC-ACID; REDUCTIVE DESORPTION; ALKANETHIOL MONOLAYERS; ADSORPTION; GOLD; IMMUNOSENSOR; STABILITY;
D O I
10.1016/j.apsusc.2021.149843
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The use of a simple protein blocking procedure prior to receptor functionalization is shown to inhibit the oxidation of carboxylic-acid-terminated thiolate self-assembled monolayers (COOH-SAMs) in ambient conditions. This finding has direct implications for the engineering and design of point-of-care and field affinity biosensors. While an abundance of label-free sensor systems utilizing COOH-SAM functional surfaces have been demonstrated, these layers degrade quickly in ambient conditions, severely limiting their shelf life. With gelatin blocking, no surface degradation is observed via X-ray photoelectron spectroscopy nor reductive desorption for 21 days, compared to observable degradation in only one day for an unblocked COOH-SAM. Additionally, unlike a traditional postblocking method that requires the sensor to first be functionalized with active receptor, this blocking procedure occurs directly after COOH-SAM formation and does not prevent the subsequent functionalization of the biosensor. These blocked sensors are shown to maintain surface-plasmon-resonance-based sensing performance for at least one week. Additionally, the blocking technique for degradation prevention is shown to even outperform COOH-SAM storage in N-2.
引用
收藏
页数:7
相关论文
共 53 条
  • [1] Ang XF, 2009, IMECE2008: PROCEEDINGS OF THE INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2008, VOL 6, P5
  • [2] Preparation, modification, and crystallinity of aliphatic and aromatic carboxylic acid terminated self-assembled monolayers
    Arnold, R
    Azzam, W
    Terfort, A
    Wöll, C
    [J]. LANGMUIR, 2002, 18 (10) : 3980 - 3992
  • [3] Engineering long shelf life multilayer biologically active surfaces on microfluidic devices for point of care applications
    Asghar, Waseem
    Yuksekkaya, Mehmet
    Shafiee, Hadi
    Zhang, Michael
    Ozen, Mehmet O.
    Inci, Fatih
    Kocakulak, Mustafa
    Demirci, Utkan
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [4] OLEOPHOBIC MONOLAYERS .1. FILMS ADSORBED FROM SOLUTION IN NON-POLAR LIQUIDS
    BIGELOW, WC
    PICKETT, DL
    ZISMAN, WA
    [J]. JOURNAL OF COLLOID SCIENCE, 1946, 1 (06): : 513 - 538
  • [5] Challenges of Electrochemical Impedance Spectroscopy in Protein Biosensing
    Bogomolova, A.
    Komarova, E.
    Reber, K.
    Gerasimov, T.
    Yavuz, O.
    Bhatt, S.
    Aldissi, M.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 3944 - 3949
  • [6] Preblocking Procedure to Mitigate Nonselective Protein Adsorption for Carboxyl-SAMs Used in Biosensing
    Brightbill, Eleanor L.
    Hitchcock, Bryce
    Tsai, Meng-Yen
    Verga, Adam
    Vogel, Eric M.
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2019, 123 (27) : 16778 - 16786
  • [7] Formation of a self-assembled monolayer via the electrospreading of physisorbed micelles of thiolates
    Byloos, M
    Al-Maznai, H
    Morin, M
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (31): : 6554 - 6561
  • [8] Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors
    Campuzano, S
    Serra, B
    Pedrero, M
    de Villena, FJM
    Pingarrón, JM
    [J]. ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) : 187 - 197
  • [9] Quartz crystal microbalance study of DNA immobilization and hybridization for nucleic acid sensor development
    Caruso, F
    Rodda, E
    Furlong, DF
    Niikura, K
    Okahata, Y
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (11) : 2043 - 2049
  • [10] VOLTAMMETRY OF COVALENTLY IMMOBILIZED CYTOCHROME-C ON SELF-ASSEMBLED MONOLAYER ELECTRODES
    COLLINSON, M
    BOWDEN, EF
    TARLOV, MJ
    [J]. LANGMUIR, 1992, 8 (05) : 1247 - 1250