Flow cytometric detection of endothelial microparticles (EMP): Effects of centrifugation and storage alter with the phenotype studied

被引:94
作者
van Ierssel, Sabrina H. [3 ]
Van Craenenbroeck, Emeline M. [1 ]
Conraads, Viviane M. [1 ]
Van Tendeloo, Viggo F. [2 ]
Vrints, Christiaan J. [1 ]
Jorens, Philippe G. [3 ]
Hoymans, Vicky Y. [1 ]
机构
[1] Univ Antwerp, Antwerp Univ Hosp UZA, Lab Cellular & Mol Cardiol, Edegem, Belgium
[2] Univ Antwerp, Antwerp Univ Hosp UZA, Ctr Cellular Therapy & Regenerat Med, Edegem, Belgium
[3] Univ Antwerp, Antwerp Univ Hosp UZA, Dept Crit Care Med, Edegem, Belgium
关键词
Centrifugation; detection; endothelial microparticles; flow cytometry; phenotype; storage; PLATELET MICROPARTICLES; DYSFUNCTION; AGREEMENT; PLASMA;
D O I
10.1016/j.thromres.2009.12.019
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Endothelial microparticles (EMP) are released into the circulation in case of endothelial disturbance, and are therefore increasingly investigated as a biomarker reflecting disease activity. Numerous pre-analytic methods have been proposed for their flow cytometric enumeration, but standardization is still lacking. In this study we evaluated the influence of centrifugation and storage conditions on EMP quantification. Materials and Methods: Platelet-poor plasma (PPP) from 10 healthy volunteers was prepared by centrifugation at 1 550 g for 20 minutes twice. A first aliquot of PPP was analyzed immediately, a second after storage at 4 degrees C for 7 hours. A third and fourth aliquot were snap-frozen and stored at -80 degrees C for 7 and 28 days. A final aliquot was further centrifuged at 10 000 g for 10 minutes and analyzed immediately. EMP were defined as CD31+CD42b-, CD62E+, CD144+ or CD144+ CD105+ particles, smaller than 1.0 mu m. Results: High speed centrifugation led to a significant loss of CD31+CD42b- EMP (p = 0.004). A good correlation between PPP and high speed centrifuged PPP was only found for CD144+ EMP (Kendall tau b = 0.611, p = 0.025). Storage at 4 degrees C did not affect EMP quantification. However, freezing at -80 degrees C increased CD31+CD42b- and CD62E+ EMP counts, and lowered CD144+ EMP (p<0.05). Nevertheless, the agreement among the different storage conditions was relatively good (Kendall coefficient of concordance >0.487; p<0.05). Conclusion: The flow cytometric detection of EMP varies with the centrifugation protocol and the storage method used, and these changes also depend on the phenotype studied. The results of this study caution against comparing study results gathered with different EMP laboratory protocols. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:332 / 339
页数:8
相关论文
共 24 条
  • [1] Abbas AK., 2005, Cellular and molecular immunology, P506
  • [2] Circulating endothelial microparticles are associated with vascular dysfunction in patients with end-stage renal failure
    Amabile, N
    Guérin, AP
    Leroyer, A
    Mallat, Z
    Nguyen, C
    Boddaert, J
    London, GM
    Tedgui, A
    Boulanger, CM
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2005, 16 (11): : 3381 - 3388
  • [3] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [4] Endothelial microparticles in diseases
    Chironi, Gilles N.
    Boulanger, Chantal M.
    Simon, Alain
    Dignat-George, Francoise
    Freyssinet, Jean-Marie
    Tedgui, Alain
    [J]. CELL AND TISSUE RESEARCH, 2009, 335 (01) : 143 - 151
  • [5] Effects of cryopreservation on lymphocyte immunophenotype and function
    Costantini, A
    Mancinia, S
    Giuliodoro, S
    Butini, L
    Regnery, CM
    Silvestri, G
    Montroni, M
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 278 (1-2) : 145 - 155
  • [6] ENJETI AK, 2007, J THROMB HAEMOST, V5
  • [7] Detection and measurement of microparticles: An evolving research tool for vascular biology
    Enjeti, Anoop K.
    Lincz, Lisa F.
    Seldon, Michael
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2007, 33 (08) : 771 - 779
  • [8] GEORGE JN, 1986, BLOOD, V68, P307
  • [9] Detection and quantification of mature circulating endothelial cells using flow cytometry and immunomagnetic beads: A methodological comparison
    Goon, Patrick K. Y.
    Boos, Christopher J.
    Stonelake, Paul S.
    Blann, Andrew D.
    Lip, Gregory Y. H.
    [J]. THROMBOSIS AND HAEMOSTASIS, 2006, 96 (01) : 45 - 52
  • [10] Horstman Lawrence L., 2004, Keio Journal of Medicine, V53, P210, DOI 10.2302/kjm.53.210