Needle-based extraction techniques with protected sorbent as powerful sample preparation tools to gas chromatographic analysis: Trends in application

被引:38
作者
Kedziora-Koch, Kamila [1 ]
Wasiak, Wieslaw [1 ]
机构
[1] Adam Mickiewicz Univ, Dept Analyt Chem, Fac Chem, Umultowska 89b, PL-61614 Poznan, Poland
关键词
Sample preparation; Microextraction; Solid-phase dynamic extraction (SPDE); In-tube extraction (ITEX); Needle trap device (NTD); Gas chromatography; SOLID-PHASE MICROEXTRACTION; VOLATILE ORGANIC-COMPOUNDS; IN-TUBE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; FLIGHT MASS-SPECTROMETRY; DYNAMIC EXTRACTION; TRAP DEVICE; PACKED NEEDLE; CARBON NANOTUBES; GEL TECHNOLOGY;
D O I
10.1016/j.chroma.2018.06.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microextraction techniques are widely applied for sample preparation togas chromatographic analysis of target compounds in samples with a complex matrix. Recently, needle-based microextraction techniques have been developed in order to improve performance of the extraction. The main advantages of these techniques are miniaturization, automation, high performance, environmentally friendliness and on-line coupling with analytical instruments. This review focuses on the three needle-based microextraction techniques including solid-phase dynamic extraction (SPDE), in-tube extraction (ITEX) and needle trap device extraction (NTD). The core of the aforementioned techniques is an extraction phase protected in the stainless steel needle. The application of the sorbent-protected needle extraction techniques for the gas chromatographic analysis of environmental, biological and food samples is discussed. The fundamental aspects and development over the years are also summarized. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 162 条
[1]   SPME Fibers for the Analysis of Pesticide Residues in Fruits and Vegetables: A Review [J].
Abdulra'uf, Lukman Bola ;
Hammed, Wasiu Adebayo ;
Tan, Guan Huat .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2012, 42 (02) :152-161
[2]   Microwave-assisted nonionic surfactant extraction of aliphatic hydrocarbons from petroleum source rock [J].
Akinlua, A. ;
Jochmann, M. A. ;
Laaks, J. ;
Ewert, A. ;
Schmidt, T. C. .
ANALYTICA CHIMICA ACTA, 2011, 691 (1-2) :48-55
[3]   Headspace needle-trap analysis of priority volatile organic compounds from aqueous samples: Application to the analysis of natural and waste waters [J].
Alonso, Monica ;
Cerdan, Laura ;
Godayol, Anna ;
Antico, Enriqueta ;
Sanchez, Juan M. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (45) :8131-8139
[4]   Needle microextraction trap for on-site analysis of airborne volatile compounds at ultra-trace levels in gaseous samples [J].
Alonso, Monica ;
Godayol, Anna ;
Antico, Enriqueta ;
Sanchez, Juan M. .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (19) :2705-2711
[5]  
[Anonymous], 1994, NIOSH MANUAL ANAL ME, V4th
[6]  
[Anonymous], OPT PREP LOAD PLATF
[7]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[8]   Development of Needle Trap Technology for On-Site Determinations: Active and Passive Sampling [J].
Asl-Hariri, Saba ;
Gomez-Rios, German A. ;
Gionfriddo, Emanuela ;
Dawes, Peter ;
Pawliszyn, Janusz .
ANALYTICAL CHEMISTRY, 2014, 86 (12) :5889-5897
[9]   A novel needle trap device with nanoporous silica aerogel packed for sampling and analysis of volatile aldehyde compounds in air [J].
Azari, Mansour R. ;
Barkhordari, Abdullah ;
Zendehdel, Rezvan ;
Heidari, Mahmoud .
MICROCHEMICAL JOURNAL, 2017, 134 :270-276
[10]   A polythiophene-silver nanocomposite for headspace needle trap extraction [J].
Bagheri, Habib ;
Banihashemi, Solmaz ;
Jelvani, Samaneh .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1460 :1-8