Sequential injection differential pulse voltammetric method based on screen printed carbon electrode modified with carbon nanotube/Nafion for sensitive determination of paraquat

被引:45
作者
Chuntib, Prakit [1 ,2 ]
Themsirimongkon, Suwaphid [1 ,2 ]
Saipanya, Surin [1 ,2 ]
Jakmunee, Jaroon [1 ,2 ,3 ]
机构
[1] Chiang Mai Univ, Dept Chem, Fac Sci, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Res Lab Analyt Instrument & Electrochem Innovat, Fac Sci, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Ctr Excellence Innovat Chem, Fac Sci, Chiang Mai 50200, Thailand
关键词
Screen-printed carbon electrode (SPCE); Carbon nanotubes (CNTs); Nafion; Sequential injection analysis; Differential pulse voltammetry; Paraquat; SQUARE-WAVE VOLTAMMETRY; PASTE ELECTRODE; LIQUID-CHROMATOGRAPHY; SPECTROPHOTOMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; MASS-SPECTROMETRY; NATURAL-WATER; FILM; DIQUAT; SYSTEM;
D O I
10.1016/j.talanta.2017.03.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The screen-printed carbon electrode (SPCE) modified with various nanoparticles has been studied for using as a working electrode in voltammetric technique. The electrochemical behavior of paraquat on different electrodes was studied by cyclic voltammetry (CV), and then differential pulse voltammetry (DPV) has been employed for trace analysis of paraquat based on redox reaction which the peak current was directly proportional to the concentration of paraquat in the solution. The SPCE modified with carbon nanotube dispersed in Nafion and ethanol (SPCE-CNT/Nafion) gave the best result. Sequential injection-differential pulse voltammetric (SI-DPV) method has been developed for more automated analysis and to reduce chemical consumption. The parameters affecting the SI-DPV system such as step potential, modulation amplitude, flow rate, and concentration of sodium chloride as an electrolyte were studied to improve the sensitivity. Under the optimum condition of the system, i.e., Nafion concentration of 1% (w/v), volume of CNT suspension of 2 mu L, flow rate of 100 mu L s(-1), step potential of 5 mV, modulation amplitude of 100 mV and concentration of sodium chloride of 1 M, a linear calibration graph in the range of 0.54-4.30 mu M with a good R-2 of 0.9955 and a limit of detection of 0.17 mu M (0.03 mg L-1) were achieved. The proposed system shows high tolerance to some possible interfering ions in natural water, surfactant, and other pesticides. The relative standard deviation (RSD) was 4.2% for 11 replicate measurements with the same electrode. The reproducibility for the preparation of 7 modified electrodes was 2.3% RSD. Recoveries of the analysis were obtained in the range of 82-106%. The developed system can be conveniently applied for analysis without pretreatment of the samples.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 39 条
[1]   Simple flow injection colorimetric system for determination of paraquat in natural water [J].
Chuntib, Prakit ;
Jakmunee, Jaroon .
TALANTA, 2015, 144 :432-438
[2]   Square-wave voltammetric determination of paraquat using a glassy carbon electrode modified with multiwalled carbon nanotubes within a dihexadecylhydrogenphosphate (DHP) film [J].
Costa Garcia, Livia Luiza ;
Soares Figueiredo-Filho, Luiz Carlos ;
Oliveira, Geiser Gabriel ;
Fatibello-Filho, Orlando ;
Banks, Craig E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 :306-311
[3]   Differential Pulse Voltammetric Determination of Paraquat Using a Bismuth-Film Electrode [J].
de Figueiredo-Filho, Luiz Carlos S. ;
dos Santos, Vagner B. ;
Janegitz, Bruno Campos ;
Guerreiro, Thiago Brito ;
Fatibello-Filho, Orlando ;
Faria, Ronald Censi ;
Marcolino-Junior, Luiz Humberto .
ELECTROANALYSIS, 2010, 22 (11) :1260-1266
[4]   Evaluation of a Nafion coated glassy carbon electrode for determination of paraquat by differential pulse voltammetry [J].
de Oliveira, UMF ;
Lichtig, J ;
Masini, JC .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (05) :735-741
[5]   Electrochemical detection of the herbicide paraquat in natural water and citric fruit juices using microelectrodes [J].
De Souza, D ;
Machado, SAS .
ANALYTICA CHIMICA ACTA, 2005, 546 (01) :85-91
[6]   Amperometric sensors based on sawdust film modified electrodes: Application to the electroanalysis of paraquat [J].
Dedzo, Gustave Kenne ;
Nanseu-Njiki, Charles Peguy ;
Ngameni, Emmanuel .
TALANTA, 2012, 99 :478-486
[7]  
Diaz TG, 2000, ELECTROANAL, V12, P616
[8]   Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode [J].
dos Santos, Luciana B. O. ;
Infante, Carlos M. C. ;
Masini, Jorge C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) :1897-1903
[9]   Use of Cdse/ZnS quantum dots for sensitive detection and quantification of paraquat in water samples [J].
Duran, Gema M. ;
Contento, Ana M. ;
Rios, Angel .
ANALYTICA CHIMICA ACTA, 2013, 801 :84-90
[10]   Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode [J].
El Harmoudi, H. ;
Achak, M. ;
Farahi, A. ;
Lahrich, S. ;
El Gaini, L. ;
Abdennouri, M. ;
Bouzidi, A. ;
Bakasse, M. ;
El Mhammedi, M. A. .
TALANTA, 2013, 115 :172-177