Loop mediated isothermal amplification of Clostridioides difficile isolates in gastrointestinal patients

被引:3
|
作者
Moosavian, Mojtaba [1 ]
Keshavarzi, Razieyeh [2 ]
Abbasi Montazeri, Effat [1 ,2 ]
Hajiani, Eskandar [3 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Hlth Res Inst, Infect & Trop Dis Res Ctr, Ahvaz, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Dept Microbiol, Fac Med, Ahvaz, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Dept Internal Med, Div Gastroenterol & Hepatol, Ahvaz, Iran
关键词
LAMP assay; PCR; Culture; Clostridioides difficile; tcdA; tcdB; INFECTION; PCR; DIAGNOSIS; TOXIN; EPIDEMIOLOGY; PREVALENCE; SPECIMENS; ADULTS; ASSAY; LAMP;
D O I
10.1186/s13568-022-01382-1
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This study investigated the prevalence of Clostridioides difficile by culture, multiplex polymerase chain reaction (M-PCR), and loop mediated isothermal amplification (LAMP) in patients with suspected C. difficile infections (CDIs). Also, the results of three methods were compared. All stool specimens collected from CDI suspected patients were cultured on selective C. difficile cycloserine-cefoxitin fructose agar and incubated in an anaerobic jar up to 7 days. The bacterial isolates were identified using standard tests. Multiplex-PCR (M-PCR) was performed for detection of tcdA, tcdB, and tpi genes. The LAMP assay was performed to detect the tcdB gene of C. difficile. C. difficile was isolated from 20.0% (n = 10/50) of samples by culture. M-PCR showed that 34.0% (n = 17/50) of the specimens were positive for C. difficile based on the presence of tpi gene. Out of the 17 C. difficile, 13 strains (76.0%) were positive for tcdB gene using M-PCR. However, the LAMP assay showed that 30.0% (15/50) of specimens were positive for the presence of tcdB gene. M-PCR and LAMP methods showed 100.0% sensitivity compared to the culture method. However, the specificity of the LAMP (87.5%) was relatively higher than the M-PCR (82.5%) compared to the culture. Based on the results of this study, the prevalence of toxigenic C. difficile strains was high in suspected CDI patients. So, the differentiation between toxigenic and non-toxigenic strains is necessary. Our data showed that the LAMP assay is a good method for direct detection of toxigenic C. difficile strains from stool specimens.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Development of loop-mediated isothermal amplification (LAMP) for simple detection of Leishmania infection
    Sriworarat, Chaichontat
    Phumee, Atchara
    Mungthin, Mathirut
    Leelayoova, Saovanee
    Siriyasatien, Padet
    PARASITES & VECTORS, 2015, 8
  • [42] Rapid detection of Trichinella spiralis larvae in muscles by loop-mediated isothermal amplification
    Li, Xuelian
    Liu, Wei
    Wang, Jie
    Zou, Dayang
    Wang, Xuesong
    Yang, Zhan
    Yin, Zhitao
    Cui, Qian
    Shang, Wei
    Li, Huan
    Wei, Xiao
    Cui, Jing
    Wang, Zhongquan
    Huang, Liuyu
    Yuan, Jing
    INTERNATIONAL JOURNAL FOR PARASITOLOGY, 2012, 42 (13-14) : 1119 - 1126
  • [43] Development of a loop-mediated isothermal amplification method for detecting virulent Rhodococcus equi
    Kinoshita, Yuta
    Niwa, Hidekazu
    Higuchi, Tohru
    Katayama, Yoshinari
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2016, 28 (05) : 608 - 611
  • [44] Development of a loop-mediated isothermal amplification method for the rapid detection of Pythium ultimum
    Shen, Danyu
    Li, Qingling
    Yu, Jia
    Zhao, Yuanyuan
    Zhu, Ye
    Xu, Heng
    Dou, Daolong
    AUSTRALASIAN PLANT PATHOLOGY, 2017, 46 (06) : 571 - 576
  • [45] Development of loop-mediated isothermal amplification test for the diagnosis of contagious agalactia in goats
    Rekha, Valsala
    Rana, Rajneesh
    Thomas, Prasad
    Viswas, Konasagara Nagaleekar
    Singh, Vijendra Pal
    Agarwal, Rajesh Kumar
    Arun, Thachappully Remesh
    Karthik, Kumaragurubaran
    Sophia, Inbaraj
    TROPICAL ANIMAL HEALTH AND PRODUCTION, 2015, 47 (03) : 581 - 587
  • [46] Establishment of Multiplex Loop-Mediated Isothermal Amplification for Rapid Detection of Genitourinary Mycoplasma
    Wang, Yichao
    Cheng, You
    Xie, Jiaogui
    Liu, Yunde
    CLINICAL LABORATORY, 2018, 64 (7-8) : 1217 - 1224
  • [47] Diagnostic accuracy of loop-mediated isothermal amplification hi detection of Clostridium difficile in stool samples: a meta-analysis
    Chen Wei
    Liu Wen-En
    Li Yang-Ming
    Luo Shan
    Zhong Yi-Ming
    ARCHIVES OF MEDICAL SCIENCE, 2015, 11 (05) : 927 - 936
  • [48] Molecular epidemiology of toxigenic Clostridioides difficile isolates from hospitalized patients and the hospital environment in Dhaka, Bangladesh
    Sofjan, Amelia K.
    Islam, Mohammad Aminul
    Halder, Kakali
    Kabir, Nayel D.
    Abu Saleh, Ahmed
    Miranda, Julie
    Lancaster, Chris
    Begum, Khurshida
    Alam, M. Jahangir
    Garey, Kevin W.
    ANAEROBE, 2020, 61
  • [49] A colorimetric assay for Neospora caninum utilizing the loop-mediated isothermal amplification technique
    Liu, Tingting
    Hu, Kairao
    Chen, Meiyi
    Hong, Hongrong
    Jiang, Xi
    Huang, Rongsheng
    Wang, Yiwen
    Huang, Jing
    Yu, Xingang
    Liu, Quan
    Wei, Zhengkai
    RESEARCH IN VETERINARY SCIENCE, 2024, 179
  • [50] The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii
    Chen, Hua-Wei
    Ching, Wei-Mei
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2016, (110):