An Evaluation of Motion Trackers with Virtual Reality Sensor Technology in Comparison to a Marker-Based Motion Capture System Based on Joint Angles for Ergonomic Risk Assessment

被引:12
|
作者
Vox, Jan P. [1 ,2 ]
Weber, Anika [3 ,4 ]
Wolf, Karen Insa [2 ]
Izdebski, Krzysztof [5 ]
Schueler, Thomas [5 ]
Koenig, Peter [6 ,7 ]
Wallhoff, Frank [1 ,2 ]
Friemert, Daniel [3 ]
机构
[1] Jade Univ Appl Sci, Inst Tech Assistance Syst ITAS, Ofener Str 16-19, D-26121 Oldenburg, Germany
[2] Fraunhofer Inst Digital Media Technol IDMT, Div Hearing Speech & Audio Technol HSA, Marie Curie Str 2, D-26129 Oldenburg, Germany
[3] Univ Appl Sci Koblenz, Dept Math & Technol, Joseph Rovan Allee 2, D-53424 Remagen, Germany
[4] London South Bank Univ, Sch Appl Sci, Sport & Exercise Sci Res Ctr, 103 Borough Rd, London SE1 0AA, England
[5] Halocline GmbH & Co KG, Netter Pl 3, D-49090 Osnabruck, Germany
[6] Univ Osnabruck, Inst Cognit Sci, Wachsbleiche 27, D-49090 Osnabruck, Germany
[7] Univ Med Ctr Hamburg Eppendorf, Inst Neurophysiol & Pathophysiol, D-20246 Hamburg, Germany
关键词
Qualisys Oqus; HTC Vive; accuracy; virtual reality; lighthouse technology; system comparison; joint angles; motion capture; ergonomic risk assessment; MUSCULOSKELETAL DISORDERS; ACCURACY; REPEATABILITY;
D O I
10.3390/s21093145
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The reproduction and simulation of workplaces, and the analysis of body postures during work processes, are parts of ergonomic risk assessments. A commercial virtual reality (VR) system offers the possibility to model complex work scenarios as virtual mock-ups and to evaluate their ergonomic designs by analyzing motion behavior while performing work processes. In this study a VR tracking sensor system (HTC Vive tracker) combined with an inverse kinematic model (Final IK) was compared with a marker-based optical motion capture system (Qualisys). Marker-based optical motion capture systems are considered the gold standard for motion analysis. Therefore, Qualisys was used as the ground truth in this study. The research question to be answered was how accurately the HTC Vive System combined with Final IK can measure joint angles used for ergonomic evaluation. Twenty-six subjects were observed simultaneously with both tracking systems while performing 20 defined movements. Sixteen joint angles were analyzed. Joint angle deviations between +/- 6 degrees and +/- 42 degrees were identified. These high deviations must be considered in ergonomic risk assessments when using a VR system. The results show that commercial low-budget tracking systems have the potential to map joint angles. Nevertheless, substantial weaknesses and inaccuracies in some body regions must be taken into account. Recommendations are provided to improve tracking accuracy and avoid systematic errors.
引用
收藏
页数:32
相关论文
共 50 条
  • [1] Comparison of the Performance of the Leap Motion ControllerTM with a Standard Marker-Based Motion Capture System
    Ganguly, Amartya
    Rashidi, Gabriel
    Mombaur, Katja
    SENSORS, 2021, 21 (05) : 1 - 16
  • [2] Comparison of 3D Joint Angles Measured With the Kinect 2.0 Skeletal Tracker Versus a Marker-Based Motion Capture System
    Guess, Trent M.
    Razu, Swithin
    Jahandar, Amirhossein
    Skubic, Marjorie
    Huo, Zhiyu
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (02) : 176 - 181
  • [3] Marker-Based Motion Capture for Measuring Joint Kinematics in Leg Swing Simulator
    Yunardi, Riky Tri
    Winarno
    2017 5TH INTERNATIONAL CONFERENCE ON INSTRUMENTATION, CONTROL, AND AUTOMATION (ICA), 2017, : 13 - 17
  • [4] Comparison of marker-less and marker-based motion capture for baseball pitching kinematics
    Fleisig, Glenn S.
    Slowik, Jonathan S.
    Wassom, Derek
    Yanagita, Yuki
    Bishop, Jasper
    Diffendaffer, Alek
    SPORTS BIOMECHANICS, 2024, 23 (12) : 2950 - 2959
  • [5] Marker-Based Real Time Motion Tracking for Sense of Virtual Body Ownership in Virtual Reality
    Wu, Linfeng
    Chen, Karen B.
    HCI INTERNATIONAL 2024-LATE BREAKING POSTERS, HCII 2024, PT II, 2025, 2320 : 54 - 59
  • [6] Concurrent assessment of gait kinematics using marker-based and markerless motion capture
    Kanko, M. Robert
    Laende, K. Elise
    Davis, M. Elysia
    Selbie, W. Scott
    Deluzio, J. Kevin
    JOURNAL OF BIOMECHANICS, 2021, 127
  • [7] Efficacy of Marker-Based Motion Capture for Respiratory Cycle Measurement: A Comparison with Spirometry
    Shamantseva, Natalia D.
    Klishkovskaia, Tatiana A.
    Ananyev, Sergey S.
    Aksenov, Andrey Y.
    Moshonkina, Tatiana R.
    SENSORS, 2023, 23 (24)
  • [8] Group Animation Motion Capture Method Based on Virtual Reality Technology
    Zhang, Songlin
    Xun, Wei
    ADVANCES IN MULTIMEDIA, 2022, 2022
  • [9] Spatial accuracy and reliability of the Microsoft Kinect V2 in the assessment of joint movement in comparison to marker-based motion capture (Vicon)
    Otte, K.
    Kayser, B.
    Mansow-Model, S.
    Brandt, A. U.
    Verrel, J.
    Schmitz-Huebsch, T.
    MOVEMENT DISORDERS, 2016, 31 : S188 - S189
  • [10] Are Wearable Sensors Valid and Reliable for Studying the Baseball Pitching Motion? An Independent Comparison With Marker-Based Motion Capture
    Camp, Christopher L.
    Loushin, Stacy
    Nezlek, Stuart
    Fiegen, Anthony P.
    Christoffer, Dan
    Kaufman, Kenton
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (11): : 3094 - 3101