Reproducibility of water drinking test performed at different times of the day

被引:16
作者
Medina, Flavio Mac Cord [1 ]
Pereira Rodrigues, Fabricio Kafury [1 ]
Ponte Pierre Filho, Paulo de Tarso [1 ]
Matsuo, Tiemi [1 ]
Cabral de Vasconcellos, Jose Paulo [1 ]
Costa, Vital Paulino [1 ]
机构
[1] Univ Estadual Campinas, UNICAMP, Glaucoma Serv, Campinas, SP, Brazil
关键词
Glaucoma; Tonometry; ocular; Reproducibility of results; Intraocular pressure; Diagnostic techniques and procedures; INTRAOCULAR-PRESSURE FLUCTUATIONS; GLAUCOMA;
D O I
10.1590/S0004-27492009000300002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility of water drinking test (WDT) performed at different times of the day, in primary open angle glaucoma (POAG) patients and normal individuals. Methods: Fifteen patients with POAG and 30 normal individuals underwent three WDTs at different times of the day (7 AM, 12 PM, and 5 PM) on 3 different days. Test results in POAG patients and normal individuals were compared. Agreement and correlation of intraocular pressure (IOP) baseline levels, peak levels, and IOP change (peak IOP - baseline IOP) on tests performed at different times were evaluated. Only right eye measurements were analyzed. Results: Mean baseline IOP, peak IOP and IOP change were significantly higher in POAG patients than in normal individuals, at all time intervals (p<0.05). The Bland-Altman analysis demonstrated limits of agreement for IOP peak levels and IOP changes larger than the clinically acceptable (>3 mmHg), even though Pearson's test revealed good correlation among the results. Conclusion: The mean IOP peak and mean IOP change observed during WDT are significantly higher in POAG patients than in control individuals. Low levels of agreement among WDTs performed at different times of the day suggest a poor reproducibility of WDT, which may limit its applicability for the diagnosis and follow-up of glaucoma.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 19 条
  • [1] Anderson D.R., 1999, Automated static perimetry, V2nd
  • [2] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [3] Carvalho CA, 1988, REV BRAS OFTALMOL, V47, P81
  • [4] DEROETTH A, 1954, AMA ARCH OPHTHALMOL, V52, P571
  • [5] DRANCE SM, 1960, ARCH OPHTHALMOL-CHIC, V64, P494
  • [6] THE WATER-DRINKING TEST
    LEYDHECKER, W
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1950, 34 (08) : 457 - 479
  • [7] Intraocular pressure fluctuations in medical versus surgically treated glaucomatous patients
    Medeiros, FA
    Pinheiro, A
    Moura, FC
    Leal, BC
    Susanna, R
    [J]. JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2002, 18 (06) : 489 - 498
  • [9] INADEQUATE DIAGNOSTIC VALUE OF WATER-DRINKING TEST
    ROTH, JA
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1974, 58 (01) : 55 - 61
  • [10] Fluctuations of intraocular pressure during the day in open-angle glaucoma, normal-tension glaucoma and normal subjects
    Saccà, SC
    Rolando, M
    Marletta, A
    Macrì, A
    Cerqueti, P
    Ciurlo, G