Commissioning of a clinical pencil beam scanning proton therapy unit for ultra-high dose rates (FLASH)

被引:53
作者
Nesteruk, Konrad P. [1 ]
Togno, Michele [1 ]
Grossmann, Martin [1 ]
Lomax, Anthony J. [1 ,2 ]
Weber, Damien C. [1 ,3 ,4 ]
Schippers, Jacobus M. [5 ]
Safai, Sairos [1 ]
Meer, David [1 ]
Psoroulas, Serena [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[4] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
[5] Paul Scherrer Inst, Div Large Res Facil, Villigen, Switzerland
基金
瑞士国家科学基金会;
关键词
FLASH; gantry; pencil beam scanning; proton therapy; ultra‐ high dose rates; LINEAR-ACCELERATOR; IRRADIATION; VALIDATION; DOSIMETRY; FACILITY; DESIGN;
D O I
10.1002/mp.14933
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this work was to provide a flexible platform for FLASH research with protons by adapting a former clinical pencil beam scanning gantry to irradiations with ultra-high dose rates. Methods PSI Gantry 1 treated patients until December 2018. We optimized the beamline parameters to transport the 250 MeV beam extracted from the PSI COMET accelerator to the treatment room, maximizing the transmission of beam intensity to the sample. We characterized a dose monitor on the gantry to ensure good control of the dose, delivered in spot-scanning mode. We characterized the beam for different dose rates and field sizes for transmission irradiations. We explored scanning possibilities in order to enable conformal irradiations or transmission irradiations of large targets (with transverse scanning). Results We achieved a transmission of 86% from the cyclotron to the treatment room. We reached a peak dose rate of 9000 Gy/s at 3 mm water equivalent depth, along the central axis of a single pencil beam. Field sizes of up to 5 x 5 mm(2) were achieved for single-spot FLASH irradiations. Fast transverse scanning allowed to cover a field of 16 x 1.2 cm(2). With the use of a nozzle-mounted range shifter, we are able to span depths in water ranging from 19.6 to 37.9 cm. Various dose levels were delivered with precision within less than 1%. Conclusions We have realized a proton FLASH irradiation setup able to investigate continuously a wide dose rate spectrum, from 1 to 9000 Gy/s in single-spot irradiation as well as in the pencil beam scanning mode. As such, we have developed a versatile test bench for FLASH research.
引用
收藏
页码:4017 / 4026
页数:10
相关论文
共 26 条
[21]   High dose-per-pulse electron beam dosimetry - A model to correct for the ion recombination in the Advanced Markus ionization chamber [J].
Petersson, Kristoffer ;
Jaccard, Maud ;
Germond, Jean-Francois ;
Buchillier, Thierry ;
Bochud, Francois ;
Bourhis, Jean ;
Vozenin, Marie-Catherine ;
Bailat, Claude .
MEDICAL PHYSICS, 2017, 44 (03) :1157-1167
[22]   The SC cyclotron and beam lines of PSI's new protontherapy facility PROSCAN [J].
Schippers, J. M. ;
Doelling, R. ;
Duppich, J. ;
Goitein, G. ;
Jermann, M. ;
Mezger, A. ;
Pedroni, E. ;
Reist, H. W. ;
Vrankovic, V. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2) :773-776
[23]   In vivo two-photon microscopy study of short-term effects of microbeam irradiation on normal mouse brain microvasculature [J].
Serduc, R ;
Vérant, P ;
Vial, JC ;
Farion, R ;
Rocas, L ;
Rémy, C ;
Fadlallah, T ;
Brauer, E ;
Bravin, A ;
Laissue, J ;
Blattmann, H ;
Van der Sanden, B .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1519-1527
[24]  
Transport G., 2007, FRAMEWORK
[25]   The Advantage of FLASH Radiotherapy Confirmed in Mini-pig and Cat-cancer Patients [J].
Vozenin, Marie-Catherine ;
De Fornel, Pauline ;
Petersson, Kristoffer ;
Favaudon, Vincent ;
Jaccard, Maud ;
Germond, Jean-Francois ;
Petit, Benoit ;
Burki, Marco ;
Ferrand, Gisele ;
Patin, David ;
Bouchaab, Hanan ;
Ozsahin, Mahmut ;
Bochud, Francois ;
Bailat, Claude ;
Devauchelle, Patrick ;
Bourhis, Jean .
CLINICAL CANCER RESEARCH, 2019, 25 (01) :35-42
[26]   Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold? [J].
Wilson, Joseph D. ;
Hammond, Ester M. ;
Higgins, Geoff S. ;
Petersson, Kristoffer .
FRONTIERS IN ONCOLOGY, 2020, 9