Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension

被引:8
作者
Pini, Claudio
Pastori, Marco
Baccheschi, Jordan
Omboni, Stefano
Parati, Gianfranco
机构
[1] Azienda Osped St Anna, Osped Cantu, Ctr Ipertens, Unita Operat Med,Dept Med, I-22063 Cantu, Como, Italy
[2] Italian Inst Telemed, Varese, Italy
[3] Univ Milano Bicocca, Dept Clin Med Prevent & Appl Biotechnol, Milan, Italy
[4] Ist Auxol Italiano, Milan, Italy
关键词
arterial hypertension; Artsana CSI 610; blood pressure measurement; International Protocol; oscillometric device; validation;
D O I
10.1097/MBP.0b013e3280b08394
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. Objective This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Methods Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). Results The Artsana CSI 610 device successfully passed phase I of study validation with the number of absolute differences between test and reference device never <35 within 5 mmHg and never <40 within 10 and 15 mmHg. The test device also passed phase 2 of the validation study with a mean (+/- SD) device-observer difference of -1.4 +/- 4.8 mmHg for systolic and -0.9 +/- 3.5 mmHg for diastolic blood pressure. Conclusions According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 18 条
[1]  
*ASS RES DEV BIOM, PRESS ART
[2]   Cardiovascular prognosis of "masked hypertension" detected by blood pressure self-measurement in elderly treated hypertensive patients [J].
Bobrie, G ;
Chatellier, G ;
Genes, N ;
Clerson, P ;
Vaur, L ;
Vaisse, L ;
Menard, J ;
Mallion, JM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (11) :1342-1349
[3]   Validation of the Omron MX3 Plus oscillometric blood pressure monitoring device according to the European Society of Hypertension international protocol [J].
Coleman, A ;
Freeman, P ;
Steel, S ;
Shennan, A .
BLOOD PRESSURE MONITORING, 2005, 10 (03) :165-168
[4]  
Lewington S, 2002, LANCET, V360, P1903, DOI 10.1016/S0140-6736(02)11911-8
[5]   BLOOD-PRESSURE, STROKE, AND CORONARY HEART-DISEASE .1. PROLONGED DIFFERENCES IN BLOOD-PRESSURE - PROSPECTIVE OBSERVATIONAL STUDIES CORRECTED FOR THE REGRESSION DILUTION BIAS [J].
MACMAHON, S ;
PETO, R ;
CUTLER, J ;
COLLINS, R ;
SORLIE, P ;
NEATON, J ;
ABBOTT, R ;
GODWIN, J ;
DYER, A ;
STAMLER, J .
LANCET, 1990, 335 (8692) :765-774
[6]   2003 European society of hypertension -: European Society of Cardiology guidelines for the management of arterial hypertension [J].
Mancia, G ;
Rosei, EA ;
Cifkova, R ;
DeBacker, G ;
Erdine, S ;
Fagard, R ;
Farsang, C ;
Heagerty, AM ;
Kawecka-Jaszcs, K ;
Kiowski, W ;
Kjeldsen, S ;
Lüscher, T ;
McInnes, G ;
Mallion, JM ;
Brien, EO ;
Poulter, NR ;
Priori, SG ;
Rahn, KH ;
Rodicio, JL ;
Ruilope, LM ;
Safar, M ;
Staessen, JA ;
van Zwieten, P ;
Waeber, B ;
Williams, B ;
Zanchetti, A ;
Zannad, F .
JOURNAL OF HYPERTENSION, 2003, 21 (06) :1011-1053
[7]   European Society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement [J].
O'Brien, E ;
Asmar, R ;
Beilin, L ;
Imai, Y ;
Mallion, JM ;
Mancia, G ;
Mengden, T ;
Myers, M ;
Padfield, P ;
Palatini, P ;
Parati, G ;
Pickering, T ;
Redon, J ;
Staessen, J ;
Stergiou, G ;
Verdecchia, P .
JOURNAL OF HYPERTENSION, 2003, 21 (05) :821-848
[8]   Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults [J].
O'Brien, E ;
Pickering, T ;
Asmar, R ;
Myers, M ;
Parati, G ;
Staessen, J ;
Mengden, T ;
Imai, Y ;
Waeber, B ;
Palatini, P ;
Atkins, N ;
Gerin, W .
BLOOD PRESSURE MONITORING, 2002, 7 (01) :3-17
[9]   AN OUTLINE OF THE REVISED BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF BLOOD-PRESSURE MEASURING DEVICES [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
ALTMAN, DG ;
BLAND, M ;
COATS, A ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1993, 11 (06) :677-679
[10]   Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: the Ohasama study [J].
Ohkubo, T ;
Asayama, K ;
Kikuya, M ;
Metoki, H ;
Obara, T ;
Saito, S ;
Hoshi, H ;
Hashimoto, J ;
Totsune, K ;
Satoh, H ;
Imai, Y .
BLOOD PRESSURE MONITORING, 2004, 9 (06) :315-320