Solid-phase microextraction and gas chromatography with mass spectrometric detection for the determination of pesticides in aqueous samples

被引:122
作者
Aguilar, C [1 ]
Peñalver, S [1 ]
Pocurull, E [1 ]
Borrull, F [1 ]
Marcé, RM [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
关键词
extraction methods; water analysis; environmental analysis; pesticides;
D O I
10.1016/S0021-9673(97)00917-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase microextraction (SPME) is a fast, alternative method for extracting organochlorine, triazine and thiocarbamate pesticides. An 85-mu m polyacrylate fiber was used to extract the analytes directly from aqueous samples and then thermal desorption was carried out in the hot injector of a gas chromatograph-mass spectrometer. To enhance the sensitivity of SPME, the temperature and the length of the extraction and desorption steps and the pH and salt concentration of the sample were optimized. The linearity of most of pesticides for real samples was found to be between 0.07 and 30 mu g 1(-1) when GC-MS under full-scan acquisition was used and between 0.005 and 10 mu g 1(-1) when selected-ion monitoring (SIM) acquisition was used. Limits of detection at the sub mu g 1(-1) level were achieved with GC and MS under the full-scan acquisition mode and at the ng 1(-1) level for MS under SIM acquisition. The repeatability of the method for tap water spiked at a level of 0.5 mu g,a 1(-1) (n=5) was below 25% (R.S.D.). (C) 1998 Elsevier Science B.V.
引用
收藏
页码:105 / 115
页数:11
相关论文
共 33 条
[1]   Determination of pesticides in environmental waters by solid-phase extraction and gas chromatography with electron-capture and mass spectrometry detection [J].
Aguilar, C ;
Borrull, F ;
Marce, RM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) :221-231
[2]  
AGUILAR C, 1986, LC GC, V14, P1048
[3]  
ARTHUR CL, 1992, HRC-J HIGH RES CHROM, V15, P741
[4]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[5]  
ARTHUR CL, 1992, LC GC-MAG SEP SCI, V10, P656
[6]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[7]   ENVIRONMENTAL-PROTECTION-AGENCY AND OTHER METHODS FOR THE DETERMINATION OF PRIORITY PESTICIDES AND THEIR TRANSFORMATION PRODUCTS IN WATER [J].
BARCELO, D .
JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2) :117-143
[8]   AUTOMATED-DETERMINATION OF S-TRIAZINE HERBICIDES USING SOLID-PHASE MICROEXTRACTION [J].
BARNABAS, IJ ;
DEAN, JR ;
FOWLIS, IA ;
OWEN, SP .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (02) :305-312
[9]   A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS [J].
BERRUETA, LA ;
GALLO, B ;
VICENTE, F .
CHROMATOGRAPHIA, 1995, 40 (7-8) :474-483
[10]  
BOQUE R, 1993, J CHEM EDUC, V70, P230