Delta Ceramic-on-Alumina Ceramic Articulation in Primary THA Prospective, Randomized FDA-IDE Study and Retrieval Analysis

被引:71
作者
Lombardi, Adolph V., Jr. [1 ,2 ,3 ,4 ]
Berend, Keith R. [1 ,2 ,3 ]
Seng, Brian E. [1 ]
Clarke, Ian C. [5 ,6 ]
Adams, Joanne B. [1 ]
机构
[1] Joint Implant Surg Inc, New Albany, OH 43054 USA
[2] Ohio State Univ, Dept Orthopaed, Columbus, OH 43210 USA
[3] Mt Carmel Hlth Syst, New Albany, OH USA
[4] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[5] Loma Linda Univ, Peterson Res Ctr, Loma Linda, CA 92350 USA
[6] Donaldson Arthrit Res Fdn, Loma Linda, CA USA
关键词
TOTAL HIP-ARTHROPLASTY; CAUSE FOP CONCERN; ACETABULAR COMPONENT; FEMORAL-HEAD; FOLLOW-UP; JOINT PROSTHESES; BEARING SURFACES; SANDWICH CUP; WEAR; SQUEAKING;
D O I
10.1007/s11999-009-1143-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Wear and osteolysis continue to be major reasons for revision surgery in THA. Ceramic-on-ceramic bearings eliminate polyethylene wear debris. The newest generation of these bearings incorporate nanosized, yttria-stabilized tetragonal zirconia particles producing an alumina matrix composite. We asked whether this new material would perform as well as a conventional bearing in terms of functional hip scores, radiographic migration and osteolysis, complications and survival. As part of a US FDA investigational device exemption study (G000075), we conducted an initial prospective safety study of 21 alumina matrix composite femoral heads articulating on alumina liners followed by a prospective, randomized study with 44 more of these articulations and 45 zirconia femoral heads on polyethylene liners. The minimum followup for all patients was 26 months (mean, 73 months; range, 26-108 months). Harris hip scores and radiographic findings were similar in the two groups as was survivorship (trial 95% versus control 93%). There were three reoperations in the trial group and three in the control group. A fractured head retrieval showed a 33% monoclinic transformation with an increase in surface roughness from 3 to 5 nm at the main wear zone. While our numbers were insufficient to compare device-related complications, the trial device performed as well as the control device in terms of reoperation, and clinical and radiographic outcome. The alumina matrix composite femoral head on an alumina liner provided high survivorship.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 53 条
[1]   Late dissociation of an alumina-on-alumina bearing modular acetabular component [J].
Akagi, M ;
Nonaka, T ;
Nishisaka, F ;
Mori, S ;
Fukuda, K ;
Hamanishi, C .
JOURNAL OF ARTHROPLASTY, 2004, 19 (05) :647-651
[2]   Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[3]  
[Anonymous], 1979, Clin Orthop Relat Res
[4]   Ceramic-on-ceramic bearings in total hip arthroplasty [J].
Bierbaum, BE ;
Nairus, J ;
Kuesis, D ;
Morrison, JC ;
Ward, D .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :158-163
[5]   PROVING THE NULL HYPOTHESIS IN CLINICAL-TRIALS [J].
BLACKWELDER, WC .
CONTROLLED CLINICAL TRIALS, 1982, 3 (04) :345-353
[6]   Current status of zirconia used in total hip implants [J].
Clarke, IC ;
Manaka, M ;
Green, DD ;
Williams, P ;
Pezzotti, G ;
Kim, YH ;
Ries, M ;
Sugano, N ;
Sedel, L ;
Delauney, C ;
Ben Nissan, B ;
Donaldson, T ;
Gustafson, GA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :73-84
[7]   Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :164-171
[8]   Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses [J].
De Aza, AH ;
Chevalier, J ;
Fantozzi, G ;
Schehl, M ;
Torrecillas, R .
BIOMATERIALS, 2002, 23 (03) :937-945
[9]   A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements [J].
Dearnley, PA .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H2) :107-135
[10]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20