Enhanced Accuracy of Continuous Glucose Monitoring by Online Extended Kalman Filtering

被引:45
作者
Facchinetti, Andrea [1 ]
Sparacino, Giovanni [1 ]
Cobelli, Claudio [1 ]
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
关键词
D O I
10.1089/dia.2009.0158
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Most continuous glucose monitoring (CGM) devices measure a current, proportional to the interstitial glucose (IG) concentration, which is converted into a glucose level by a standard device calibration step that exploits some blood glucose (BG) references. However, data show that deterioration of sensor gain may occur, which can affect CGM output by a systematic and possibly large (e. g., up to 15/20mg/dL) error. Enhanced calibration algorithms for improving the accuracy of CGM are thus of critical importance, especially in real-time applications. Methods: In this work we present an enhanced Bayesian calibration method that can be implemented online by using the Extended Kalman Filter. The method takes into account the existence of BG-to-IG kinetics by incorporating a population convolution model and exploits only four BG reference samples per day. Results: The new method is successfully applied on 10 simulated virtual patients. Its performance in improving the accuracy of CGM profiles is significantly better than that of other current calibration procedures. Furthermore, the new method is shown to be robust to changes in its parameters. Improvement in the accuracy of CGM is also shown on a representative subject. Conclusions: Realistic simulations show that the new enhanced calibration method significantly improves the accuracy of CGM signals, suggesting potential benefits by its inclusion in real-time applications of CGM devices.
引用
收藏
页码:353 / 363
页数:11
相关论文
共 28 条
[1]  
Anderson B.D.O., 1979, Optimal Filtering
[2]   Clinical Use of Real-Time Continuous Glucose Monitoring [J].
Battelino, Tadej ;
Bolinder, Jan .
CURRENT DIABETES REVIEWS, 2008, 4 (03) :218-222
[3]  
Breton Marc, 2008, J Diabetes Sci Technol, V2, P853
[4]  
Buckingham BA, 2006, DIABETES TECHNOL THE, V8, P318
[5]   Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care [J].
Chase, J. Geoffrey ;
Hann, Christopher E. ;
Jackson, Monique ;
Lin, Jessica ;
Lotz, Thomas ;
Wong, Xing-Wei ;
Shaw, Geoffrey M. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 82 (03) :238-247
[6]  
Dalla Man Chiara, 2007, J Diabetes Sci Technol, V1, P323
[7]   Minimally-Invasive and Non-Invasive Continuous Glucose Monitoring Systems: Indications, Advantages, Limitations and Clinical Aspects [J].
De Block, Christophe ;
Vertommen, Jan ;
Manuel-y-Keenoy, Begona ;
Van Gaal, Luc .
CURRENT DIABETES REVIEWS, 2008, 4 (03) :159-168
[8]   Nonparametric input estimation in physiological systems: Problems, methods, and case studies [J].
DeNicolao, G ;
Sparacino, G ;
Cobelli, C .
AUTOMATICA, 1997, 33 (05) :851-870
[9]  
Facchinetti Andrea, 2007, J Diabetes Sci Technol, V1, P617
[10]   An Online Self-Tunable Method to Denoise CGM Sensor Data [J].
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Cobelli, Claudio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (03) :634-641