The dose response of PTW microDiamond and microSilicon in transverse magnetic field under small field conditions

被引:11
|
作者
Blum, Isabel [1 ]
Tekin, Tuba [1 ]
Delfs, Bjorn [1 ]
Schonfeld, Ann-Britt [1 ]
Kapsch, Ralf-Peter [2 ]
Poppe, Bjorn [1 ]
Looe, Hui Khee [1 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Univ Clin Med Radiat Phys, Pius Hosp, Med Campus, Oldenburg, Germany
[2] Phys Tech Bundesanstalt, Braunschweig, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 15期
关键词
magnetic resonance guided radiation therapy; Lorentz force; magnetic field; small field dosimetry; dose response; small field output correction factors; MONTE-CARLO; ION CHAMBERS; DETECTORS; DOSIMETRY; DIAMOND; DIODE;
D O I
10.1088/1361-6560/ac0f2e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the present work is to investigate the behavior of two diode-type detectors (PTW microDiamond 60019 and PTW microSilicon 60023) in transverse magnetic field under small field conditions. A formalism based on TRS 483 has been proposed serving as the framework for the application of these high-resolution detectors under these conditions. Measurements were performed at the National Metrology Institute of Germany (PTB, Braunschweig) using a research clinical linear accelerator facility. Quadratic fields corresponding to equivalent square field sizes S between 0.63 and 4.27 cm at the depth of measurement were used. The magnetic field strength was varied up to 1.4 T. Experimental results have been complemented with Monte Carlo simulations up to 1.5 T. Detailed simulations were performed to quantify the small field perturbation effects and the influence of detector components on the dose response. The does response of both detectors decreases by up to 10% at 1.5 T in the largest field size investigated. In S = 0.63 cm, this reduction at 1.5 T is only about half of that observed in field sizes S > 2 cm for both detectors. The results of the Monte Carlo simulations show agreement better than 1% for all investigated conditions. Due to normalization at the machine specific reference field, the resulting small field output correction factors for both detectors in magnetic field k(Qclin,Qmsr)(B) are smaller than those in the magnetic field-free case, where correction up to 6.2% at 1.5 T is required for the microSilicon in the smallest field size investigated. The volume-averaging effect of both detectors was shown to be nearly independent of the magnetic field. The influence of the enhanced-density components within the detectors has been identified as the major contributors to their behaviors in magnetic field. Nevertheless, the effect becomes weaker with decreasing field size that may be partially attributed to the deficiency of low energy secondary electrons originated from distant locations in small fields.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Role of transverse magnetic field in the capacitive discharge
    You, S. J.
    Hai, T. T.
    Park, M.
    Kim, D. W.
    Kim, J. H.
    Seong, D. J.
    Shin, Y. H.
    Lee, S. H.
    Park, G. Y.
    Lee, J. K.
    Chang, H. Y.
    THIN SOLID FILMS, 2011, 519 (20) : 6981 - 6989
  • [22] Hysteresis of superconducting cylinder in transverse magnetic field
    Zhilichev, YN
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (03) : 1657 - 1661
  • [23] Concerning arc discharge in a transverse magnetic field
    Zharinov, AV
    PLASMA PHYSICS REPORTS, 2003, 29 (07) : 631 - 634
  • [24] Concerning arc discharge in a transverse magnetic field
    A. V. Zharinov
    Plasma Physics Reports, 2003, 29 : 631 - 634
  • [25] Wave beams in a plasma in a transverse magnetic field
    Bagdoev A.G.
    Sedrakian D.M.
    Astrophysics, 2001, 44 (1) : 113 - 120
  • [26] Dynamical anisotropic response of black phosphorus under magnetic field
    Liu, Xuefeng
    Lu, Wei
    Zhou, Xiaoying
    Zhou, Yang
    Zhang, Chenglong
    Lai, Jiawei
    Ge, Shaofeng
    Sekhar, M. Chandra
    Jia, Shuang
    Chang, Kai
    Sun, Dong
    2D MATERIALS, 2018, 5 (02):
  • [27] The effects of a transverse magnetic field on the dose enhancement of nanoparticles in a proton beam: a Monte Carlo simulation
    Parishan, Mohammadreza
    Faghihi, Reza
    Kadoya, Noriyuki
    Jingu, Keiichi
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (08):
  • [28] Technical Note: Enhancing the surface dose using a weak longitudinal magnetic field
    Carlone, Marco
    Tadic, Tony
    Keller, Harald
    Rezaee, Mohammad
    Jaffray, David
    MEDICAL PHYSICS, 2016, 43 (06) : 2927 - 2932
  • [29] Investigation of the dose perturbation effect for therapeutic beams with the presence of a 1.5 T transverse magnetic field in magnetic resonance imaging-guided radiotherapy
    Shao, Wencheng
    Tang, Xiaobin
    Bai, Yanling
    Shu, Diyun
    Geng, Changran
    Gong, Chunhui
    Guan, Fada
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (01) : 184 - 195
  • [30] Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: Effect of field size, surface orientation, magnetic field strength, and exit bolus
    Oborn, B. M.
    Metcalfe, P. E.
    Butson, M. J.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2010, 37 (10) : 5208 - 5217