Diagnostic accuracy of 4 intraoral radiographic techniques for misfit detection at the implant abutment joint

被引:14
|
作者
Daros, Pollyana [1 ]
Carneiro, Vinicius Cavalcanti [1 ]
Siqueira, Amanda Pasolini [1 ]
de-Azevedo-Vaz, Sergio Lins [1 ]
机构
[1] Univ Fed Espirito Santo, Dept Clin Dent, Vitoria, ES, Brazil
关键词
FINITE-ELEMENT-ANALYSIS; SUPPORTED PROSTHESES; BONE LOSS; INTERFACE; FIT; MICROGAP; DENTISTRY;
D O I
10.1016/j.prosdent.2017.08.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A misfit or gap at the implant abutment joint (IAJ) requires detection as it may compromise the health of the peri-implant tissue. However, which radiographic technique provides the most orthogonal relationship between the central beam and the implant/image receptor is unclear. Purpose. The purpose of this in vitro study was to evaluate the diagnostic accuracy of 4 intraoral radiographic techniques on misfit detection at the IAJ. Material and methods. Twenty implants were placed in polyamide jaws, and customized dental implant abutments with a metal collar were installed. Different gaps were simulated by placing one or three 50-1.1m-thick polyester strips at the IAJ; the absence of the strip represented the control group (no gap). The 4 radiographic techniques were evaluated by using different film holders: a periapical with bisecting angle (PBA), a bitewing interproximal (BI), a periapical with standard paralleling (PSP), and a periapical with modified paralleling (PMP) holder (with a custom-made paralleling index). A total of 240 digital radiographs were evaluated by 4 clinicians experienced with dental implants. Differences were evaluated by using receiver operating characteristic (ROC) curves (Az) and Fisher tests (alpha=.05). Diagnostic values (sensitivity, specificity, accuracy, and positive and negative predictive values) were also obtained. The Kappa test was used to assess intra-and interevaluator reproducibility, which ranged from moderate to almost perfect. Results. All diagnostic values, except specificity, were lower for the PBA technique for both the 50 and 150-mu m gaps. Az values for the PBA technique were significantly lower than those obtained for the other 3 techniques (P<.05), which did not differ from each other. The 150-mu m gaps were more easily detected than the 50-mu m gaps only for PBA (P<.05). Conclusions. The BI, PSP, and PMP techniques detected misfits at the IAJ most accurately. The PBA technique is not recommended for this purpose.
引用
收藏
页码:57 / 64
页数:8
相关论文
共 9 条
  • [1] Accuracy of Digital Versus Conventional Periapical Radiographs to Detect Misfit at the Implant-Abutment Interface
    Cancado Oliveira, Bruno Fernando
    Valerio, Claudia Scigliano
    Jansen, Wellington Correa
    Zenobio, Elton Goncalves
    Manzi, Flavio Ricardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1023 - 1029
  • [2] Three-Dimensional Accuracy of Implant and Abutment Level Impression Techniques: Effect on Marginal Discrepancy
    Alikhasi, Marzieh
    Siadat, Hakimeh
    Monzavi, Abbas
    Momen-Heravi, Fatemeh
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (06) : 649 - 657
  • [3] Tactile misfit detection ability at the implant-abutment interface of internal connection dental implants: an in-vitro study
    Molinero-Mourelle, Pedro
    Peter, Lukas
    Gaviria, Ana Sol
    Fonseca, Manrique
    Schimmel, Martin
    Katsoulis, Joannis
    ACTA ODONTOLOGICA SCANDINAVICA, 2023, 81 (08) : 591 - 596
  • [4] Evaluation of accuracy of deep learning and conventional neural network algorithms in detection of dental implant type using intraoral radiographic images: A systematic review and meta-analysis
    Dashti, Mahmood
    Londono, Jimmy
    Ghasemi, Shohreh
    Tabatabaei, Shivasadat
    Hashemi, Sara
    Baghaei, Kimia
    Palma, Paulo J.
    Khurshid, Zohaib
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01) : 137 - 146
  • [5] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    BMC ORAL HEALTH, 2021, 21 (01)
  • [6] Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed prostheses: A prospective study
    Yan, Yuwei
    Lin, Xiao
    Yue, Xinxin
    Geng, Wei
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04) : 564 - 572
  • [7] Accuracy of Definitive Casts Using 4 Implant-Level Impression Techniques in a Scenario of Multi-Implant System With Different Implant Angulations and Subgingival Alignment Levels
    Martinez-Rus, Francisco
    Garcia, Carmen
    Santamaria, Andrea
    Ozcan, Mutlu
    Pradies, Guillermo
    IMPLANT DENTISTRY, 2013, 22 (03) : 268 - 276
  • [8] Defect morphology, bone thickness, exposure settings and examiner experience affect the diagnostic accuracy of standardized digital periapical radiographic images but not of cone beam computed tomography in the detection of peri-implant osseous defects: An in vitro study
    Pelekos, George
    Tse, Judy M. N.
    Ho, Dominic
    Tonetti, Maurizio S.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2019, 46 (12) : 1294 - 1302
  • [9] Do the number of zirconia implants and the thickness of CBCT image reconstruction affect the detection of peri-implant bone defect? A diagnostic accuracy ex vivo study
    da Fonte, Juliana Batista Melo
    Fontenele, Rocharles Cavalcante
    Farias-Gomes, Amanda
    Ruiz, Debora Costa
    Andrade-Bortoletto, Maria Fernanda Silva
    Melo, Saulo L. Sousa
    Freitas, Deborah Queiroz
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (11) : 1485 - 1492