Accuracy of a laboratory-based computer implant guiding system

被引:13
作者
Barnea, Eitan [1 ]
Alt, Ido [2 ]
Kolerman, Roni
Nissan, Joseph [1 ]
机构
[1] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Oral Rehabil, IL-69978 Tel Aviv, Israel
[2] Tel Aviv Univ, Maurice & Gabriela Goldschleger Sch Dent Med, Dept Periodontol, IL-69978 Tel Aviv, Israel
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2010年 / 109卷 / 05期
关键词
STEREOLITHOGRAPHIC SURGICAL GUIDES; NAVIGATION SYSTEM; ORAL IMPLANTS; PLACEMENT; RELIABILITY; PRECISION; TEMPLATE; IMAGES;
D O I
10.1016/j.tripleo.2010.01.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. Computer-guided implant placement is a growing treatment modality in partially and totally edentulous patients, though data about the accuracy of some systems for computer-guided surgery is limited. The purpose of this study was to evaluate the accuracy of a laboratory computer-guided system. Study design. A laboratory-based computer guiding system (M Guide; MIS technologies, Shlomi, Israel) was used to place implants in a fresh sheep mandible. A second computerized tomography (CT) scan was taken after placing the implants. The drill plan figures of the planned implants were positioned using assigned software (Med3D, Heidelberg, Germany) on the second CT scan to compare the implant position with the initial planning. Values representing the implant locations of the original drill plan were compared with that of the placed implants using SPSS software. Results. Six measurements (3 vertical, 3 horizontal) were made on each implant to assess the deviation from the initial implant planning. A repeated-measurement analysis of variance was performed comparing the location of measurement (center, abutment, apex) and type of deviation (vertical vs. horizontal). The vertical deviation (mean -0.168) was significantly smaller than the horizontal deviation (mean 1.148). Conclusion. The laboratory computer-based guiding system may be a viable treatment concept for placing implants. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e6-e10)
引用
收藏
页码:E6 / E10
页数:5
相关论文
共 31 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
[2]   Biomechanical aspects of initial intraosseous stability and implant design:: a quantitative micro-morphometric analysis [J].
Akca, Kivanc ;
Chang, Ting-Ling ;
Tekdemir, Ibrahim ;
Fanuscu, Mete I. .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (04) :465-472
[3]   Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography [J].
Besimo, CE ;
Lambrecht, JT ;
Guindy, JS .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (01) :46-51
[4]   10-YEAR SURVIVAL RATES OF FIXED PROSTHESES ON 4 OR 6 IMPLANTS AD-MODUM BRANEMARK IN FULL EDENTULISM [J].
BRANEMARK, PI ;
SVENSSON, B ;
VANSTEENBERGHE, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :227-231
[5]   Navigation surgery for dental implants: Assessment of accuracy of the image guided implantology system [J].
Casap, N ;
Wexler, A ;
Persky, N ;
Schneider, A ;
Lustmann, J .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (09) :116-119
[6]  
Chiu WK, 2006, INT J ORAL MAX IMPL, V21, P465
[7]  
Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
[8]   Image-guided removal of foreign bodies [J].
Eggers, G ;
Haag, C ;
Hassfeld, S .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2005, 43 (05) :404-409
[9]  
Ersoy AE, 2008, J PERIODONTOL, V79, P1339, DOI [10.1902/jop.2008.080059, 10.1902/jop.2008.080059 ]
[10]  
Feng E, 2006, INT J COMPUT ASS RAD, V1, P417