High-Resolution Differential Ion Mobility Separations Using Helium-Rich Gases

被引:86
作者
Shvartsburg, Alexandre A. [1 ]
Danielson, William F. [1 ]
Smith, Richard D. [1 ]
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
关键词
ESI-FAIMS-MS; SPECTROMETRY-MASS SPECTROMETRY; PHASE SEPARATIONS; PEAK-CAPACITY; FIELD; CONFORMERS; PROTEOMICS; SENSITIVITY; UBIQUITIN; PEPTIDE;
D O I
10.1021/ac902852a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analyses of complex mixtures and characterization of ions increasingly involve gas-phase separations by ion mobility spectrometry (IMS) and particularly differential or field asymmetric waveform IMS (FAIMS) based on the difference of ion mobility in strong and weak electric fields. The key advantage of FAIMS is substantial orthogonality to mass spectrometry (MS), which makes FAIMS/MS hybrid a powerful analytical platform of broad utility. However, the potential of FAIMS has been constrained by limited resolution. Here, we report that the use of gas mixtures comprising up to 75% He dramatically increases the FAIMS separation capability, with the resolving power for peptides and peak capacity for protein digests reaching and exceeding 100. The resolution gains extend to small molecules, where previously unresolved isomers can now be separated. These performance levels open major new applications of FAIMS in proteomic and other biomolecular analyses.
引用
收藏
页码:2456 / 2462
页数:7
相关论文
共 44 条
[1]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[2]  
[Anonymous], 2005, ION MOBILITY SPECTRO, DOI DOI 10.1201/9781420038972
[3]  
Asbury GR, 2000, J MICROCOLUMN SEP, V12, P172, DOI 10.1002/(SICI)1520-667X(2000)12:3<172::AID-MCS7>3.3.CO
[4]  
2-N
[5]   Ion mobility spectrometry-mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures [J].
Baker, Erin Shammel ;
Clowers, Brian H. ;
Li, Fumin ;
Tang, Keqi ;
Tolmachev, Aleksey V. ;
Prior, David C. ;
Belov, Mikhail E. ;
Smith, Richard D. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (07) :1176-1187
[6]   Separation of leucine and isoleucine by electrospray ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry [J].
Barnett, DA ;
Ells, B ;
Guevremont, R ;
Purves, RW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1279-1284
[7]  
Bernstein SL, 2009, NAT CHEM, V1, P326, DOI [10.1038/nchem.247, 10.1038/NCHEM.247]
[8]   Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics [J].
Canterbury, Jesse D. ;
Yi, Xianhua ;
Hoopmann, Michael R. ;
MacCoss, Michael J. .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :6888-6897
[9]   High-resolution ion mobility measurements [J].
Dugourd, P ;
Hudgins, RR ;
Clemmer, DE ;
Jarrold, MF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (02) :1122-1129
[10]   Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS [J].
Guevremont, R ;
Barnett, DA ;
Purves, RW ;
Vandermey, J .
ANALYTICAL CHEMISTRY, 2000, 72 (19) :4577-4584