Analysis on dielectric recovery characteristics of 500kV 1-Break SF6 circuit breaker

被引:0
|
作者
Cao, YD [1 ]
Liu, XM [1 ]
Wang, EZ [1 ]
机构
[1] Shenyang Univ Technol, Coll Elect Engn, Shenyang 110023, Peoples R China
来源
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In development of extreme high voltage SF6 circuit breaker, the most important problem to be investigated is the dielectric recovery characteristic, which mainly depends on the electric field distribution and SF6 gas flow state in arc quenching chamber during the opening process. In this paper, the combined mathematical model of the electric field, flow field and turbulent flow has been established. For calculating the flow-field, a new method combined improved Total Variation Diminish scheme (TVD) with Finite Volume Method (FVM) has been developed. The time variant electric field and flow field is solved so that the dielectric recovery characteristic of 500kV 1-break SF6 circuit breaker with different nozzle structure is investigated. The taboo search optimization algorithm has been improved and applied in optimizing the electric field distribution for improving the dielectric recovery characteristic. As the simulation of all above-mentioned research, the visualization of whole computation course in the 500kV 1-break SF6 circuit breaker is accomplished.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [31] Gas flow characteristics analysis of SF6 circuit breaker using similarity theory
    Li, Liying
    Chen, Hai
    Zhang, Yaqian
    Liu, Wei
    Liu, Xiaoming
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2420 - 2425
  • [32] Research of Cold Rate of Rise of Dielectric Strength of SF6 Circuit Breaker
    Chernoskutov, Dmitry
    2015 INTERNATIONAL SIBERIAN CONFERENCE ON CONTROL AND COMMUNICATIONS (SIBCON), 2015,
  • [33] Defect Analysis of the Basin-type Insulator in a 500kV SF6 Current Transformer
    Zhao, Yingyu
    Ji, Sheng
    Zhang, Wenming
    Liu, Xingwei
    Hu, Runge
    Wang, Xin
    2024 INTERNATIONAL CONFERENCE ON ELECTRONICS, ELECTRICAL AND CONTROL SYSTEM, EECS 2024, 2024, 2800
  • [34] 500kV SF6断路器爆炸事故分析
    任众楷
    时鑫
    黑龙江科技信息, 2015, (23) : 10 - 11
  • [35] Pressure and Arc Voltage Measurement in a 252 kV SF6 Puffer Circuit Breaker
    Zhong Jianying
    Guo Yujing
    Zhang Hao
    PLASMA SCIENCE & TECHNOLOGY, 2016, 18 (05) : 490 - 493
  • [36] SF6 MAGNETIC-PUFFER CIRCUIT BREAKER FOR 34.5 KV 1500 MVA
    FRINK, R
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (03): : 742 - &
  • [37] Pressure and Arc Voltage Measurement in a 252 kV SF6 Puffer Circuit Breaker
    钟建英
    郭煜敬
    张豪
    Plasma Science and Technology, 2016, (05) : 490 - 493
  • [39] Electrical Strength Analysis of SF6 Gas Circuit Breaker Element
    Glushkov, Daniil A.
    Khalyasmaa, Alexandra I.
    Dmitriev, Stepan A.
    Kokin, Sergey E.
    2ND AASRI CONFERENCE ON POWER AND ENERGY SYSTEMS (PES2013), 2014, 7 : 57 - 61
  • [40] INSULATION COORDINATION QUALITIES OF 500-KV SF6 CIRCUIT BREAKERS
    SONNENBE.CF
    BRADO, JJ