Attenuation measurement system in the frequency range of 10 to 100 MHz

被引:16
|
作者
Widarta, A [1 ]
Tomoteru, K [1 ]
机构
[1] Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058563, Japan
关键词
attenuation measurement; radio frequency; standard;
D O I
10.1109/TIM.2003.810010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An attenuation measurement system, which employs a traceable inductive voltage divider (IVD) at 1 kHz as a reference standard and dual-channel intermediate frequency (IF) substitution method, is developed as an attenuation standard in the frequency range of 10 to 100 MHz. High isolation between the channels is achieved by introducing an assembly of light emission diode, optical fiber, and photodetector into the system. Sources of uncertainties of the system, such as leakage, are discussed and the expanded uncertainties are expected to be 0.001 dB for an attenuation range up to 20 dB and 0.04 dB for 80 dB.
引用
收藏
页码:302 / 305
页数:4
相关论文
共 50 条
  • [41] Measurement of complex permittivity of liquids in the frequency range 100-1000 MHz by using a re-entrant cavity
    Cheng, Jin
    Peng, Yitong
    Li, En
    Yu, Chengyong
    Zhang, Yunpeng
    Gao, Yong
    Gao, Chong
    Long, Jiawei
    Tu, Yihang
    Qin, Lin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (10):
  • [42] A fast network analyzer for the frequency range of 10 MHz to 4 GHz
    Schulte, B
    Musch, T
    Schiek, B
    33RD EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2003, : 97 - 100
  • [43] COMPLEX BIOELECTRIC IMPEDANCE MEASUREMENT SYSTEM FOR THE FREQUENCY-RANGE FROM 5 HZ TO 1 MHZ
    ACKMANN, JJ
    ANNALS OF BIOMEDICAL ENGINEERING, 1993, 21 (02) : 135 - 146
  • [44] A new oscillator circuit effective in frequency range 100 MHz to 1 GHz
    Adachi, T
    Kawagishi, M
    Izumiya, S
    Nomura, N
    Aoyagi, Y
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXPOSITION, 2005, : 710 - 713
  • [45] Origin of noise in AlGaN/GaN heterostructures in the range of 10-100 MHz
    Vitusevich, SA
    Danylyuk, SV
    Kurakin, AM
    Klein, N
    Offenhäusser, A
    Petrychuk, MV
    Belyaev, AE
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (07)
  • [46] METHOD FOR MEASURING IMPEDANCE OF MONOPOLE ANTENNAS IN THE RANGE 10-100 MHZ
    POPOVIC, BD
    SURUTKA, JV
    SIXTH INTERNATIONAL CONFERENCE ON ANTENNAS AND PROPAGATION ( ICAP 89 ), PARTS 1-2, 1989, 301 : A478 - A481
  • [47] State Verification Schedule for Means of Measurement of Electrical Quality Factor in the Frequency Range from 10 Hz to 300 MHz
    Abrosimov, E. A.
    Eremtsova, S. V.
    Mamonov, A. A.
    Maloshenko, O. J.
    2014 12TH INTERNATIONAL CONFERENCE ON ACTUAL PROBLEMS OF ELECTRONICS INSTRUMENT ENGINEERING (APEIE), 2014, : 162 - 167
  • [48] Influence of diesel fuel contamination on the electrical properties of unsaturated soil at a low frequency range of 100 Hz-10 MHz
    Son, Younghwan
    Oh, Myounghak
    Lee, Seunghak
    ENVIRONMENTAL GEOLOGY, 2009, 58 (06): : 1341 - 1348
  • [49] MEASUREMENT OF ATTENUATION COEFFICIENTS IN FREQUENCY RANGE 1-20 KHZ
    GUPTA, SP
    SINGH, AK
    SINGHAL, V
    TANTRY, BAP
    JOURNAL OF GEOMAGNETISM AND GEOELECTRICITY, 1974, 26 (01): : 95 - 100
  • [50] Investigation of Frequency Characteristics of Electromagnetic Interference Attenuation by a High-Frequency Filter in a Frequency Range from 9 kHz to 100 MHz in Aerospace Systems when Operating on a Variable Load
    V. F. Dmitrikov
    A. K. Nevolin
    D. V. Shushpanov
    A. A. Vyalov
    A. Yu. Petrochenko
    Russian Aeronautics, 2024, 67 (4): : 959 - 973