Attenuation measurement system in the frequency range of 10 to 100 MHz

被引:16
|
作者
Widarta, A [1 ]
Tomoteru, K [1 ]
机构
[1] Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058563, Japan
关键词
attenuation measurement; radio frequency; standard;
D O I
10.1109/TIM.2003.810010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An attenuation measurement system, which employs a traceable inductive voltage divider (IVD) at 1 kHz as a reference standard and dual-channel intermediate frequency (IF) substitution method, is developed as an attenuation standard in the frequency range of 10 to 100 MHz. High isolation between the channels is achieved by introducing an assembly of light emission diode, optical fiber, and photodetector into the system. Sources of uncertainties of the system, such as leakage, are discussed and the expanded uncertainties are expected to be 0.001 dB for an attenuation range up to 20 dB and 0.04 dB for 80 dB.
引用
收藏
页码:302 / 305
页数:4
相关论文
共 50 条
  • [31] Development of disposable membrane hydrophones for a frequency range from 1 MHz to 10 MHz
    Lee, Jae-Wan
    Ohm, Won-Suk
    Kim, Yong-Tae
    ULTRASONICS, 2017, 81 : 50 - 58
  • [32] NONCONTACT MEASUREMENT OF ACOUSTIC-EMISSION SIGNALS IN THE 100 MHZ FREQUENCY-RANGE USING AN ACOUSTICAL MICROSCOPE
    KANAI, H
    CHUBACHI, N
    SANNOMIYA, T
    ACUSTICA, 1992, 76 (04): : 199 - 204
  • [33] ACTIVE ANTENNAS IN FREQUENCY RANGE FROM 100 KHZ TO 250 MHZ
    FLACHENECKER, G
    LANDSTORFER, F
    LINDENMEIER, H
    NACHRICHTENTECHNISCHE ZEITSCHRIFT, 1971, 24 (05): : 231 - +
  • [34] BULK WAVE RESONATOR FOR 100-300 MHZ FREQUENCY RANGE
    COUSSOT, GJ
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1975, SU22 (03): : 225 - 225
  • [35] PRECISE MEASUREMENT OF ULTRASONIC-ABSORPTION IN MICELLAR SOLUTIONS IN THE FREQUENCY-RANGE FROM 0.2 TO 10 MHZ
    KATO, S
    NOMURA, H
    ZIELINSKI, R
    IKEDA, S
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1986, 59 (03) : 707 - 713
  • [36] LIVER FREQUENCY ATTENUATION MEASUREMENT WITH THE DIASONICS SYSTEM
    MEIRE, HB
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1984, 5 (04): : 321 - 321
  • [37] A study on frequency dependence of ultrasound attenuation of biological tissue in the frequency range of 2-40 MHz
    Nakajima, K
    Kudo, N
    Yamamoto, K
    Mikami, T
    Kitabatake, A
    1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1381 - 1384
  • [38] ULTRASOUND CHARACTERIZATION OF NORMAL OCULAR TISSUE IN THE FREQUENCY-RANGE FROM 50 MHZ TO 100 MHZ
    YE, SG
    HARASIEWICZ, KA
    PAVLIN, CJ
    FOSTER, FS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (01) : 8 - 14
  • [39] The Effective Magnetic Permeability of Ferrite Rods M400HH in the Frequency Range of 10-100 MHz
    Ogurtsova, T. N.
    Pochanin, G. P.
    Kholod, P., V
    2016 8TH INTERNATIONAL CONFERENCE ON ULTRAWIDEBAND AND ULTRASHORT IMPULSE SIGNALS (UWBUSIS), 2016, : 139 - 141
  • [40] ULTRASONIC VELOCITY AND ATTENUATION MEASUREMENTS IN LIQUIDS WITH RESONATORS, EXTENDING THE MHZ FREQUENCY-RANGE
    EGGERS, F
    ACUSTICA, 1992, 76 (05): : 231 - 240