In-plane shear strength and damage fragility functions for partially-grouted reinforced masonry walls with bond-beam reinforcement

被引:14
作者
Zhang, Zhiming [1 ]
Murcia-Delso, Juan [2 ]
Sandoval, Cristian [3 ,4 ]
Araya-Letelier, Gerardo [5 ]
Wang, Fenglai [1 ,6 ,7 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Univ Politecn Cataluna, Dept Civil & Environm Engn, C Jordi Girona 1-3,Bldg C1, Barcelona 08034, Spain
[3] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[5] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
[6] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[7] Harbin Inst Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
关键词
Reinforced masonry; Partially-grouted walls; In-plane shear strength; Fragility functions; Seismic performance;
D O I
10.1016/j.engstruct.2021.112569
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a study on the in-plane shear response of partially-grouted reinforced masonry walls with bond-beam reinforcement. A database of 95 tests on partially-grouted walls made of concrete hollow blocks was compiled from experimental studies reported in the literature to characterize the capacity and damageability of walls subjected to in-plane lateral loading. The database has been used to evaluate the accuracy of existing design shear strength equations for partially-grouted walls. It is concluded that the shear strength expressions in the Masonry Standards Joint Committee (MSJC) code and Canadian standard are unconservative for partiallygrouted walls. A modified equation based on the MSJC expression is proposed which better estimates the shear strength of this type of walls. Seismic fragility functions are also derived based on the experimental database to calculate the probability of experiencing moderate and severe damage in a partially-grouted wall for a given story-drift ratio deformation or normalized shear force demand. The resulting fragility functions show that the normalized shear demand is better correlated with the level of damage than the story-drift ratio.
引用
收藏
页数:15
相关论文
共 44 条
[1]  
Anderson D., 1992, P 6 CAN MAS S SASK S
[2]  
[Anonymous], 2004, 42302004 NZS
[3]   Fragility functions for partially-grouted masonry shear walls with bed-joint reinforcement [J].
Araya-Letelier, Gerardo ;
Calderon, Sebastian ;
Sandoval, Cristian ;
Sanhueza, Matias ;
Murcia-Delso, Juan .
ENGINEERING STRUCTURES, 2019, 191 :206-218
[4]  
Baenziger G, 2011, P 11 N AM MAS C
[5]   Shear strength expression for partially grouted masonry walls [J].
Bolhassani, M. ;
Hamid, A. A. ;
Johnson, C. ;
Schultz, A. E. .
ENGINEERING STRUCTURES, 2016, 127 :475-494
[6]   Enhancement of lateral in-plane capacity of partially grouted concrete masonry shear walls [J].
Bolhassani, M. ;
Hamid, A. A. ;
Moon, F. L. .
ENGINEERING STRUCTURES, 2016, 108 :59-76
[7]  
Bolhassani M., 2015, THESIS DREXEL U US
[8]  
Calderon S., 2018, PROC 10 INT MASON SO, P1146
[9]   Quasi-static testing of concrete masonry shear walls with different horizontal reinforcement schemes [J].
Calderon, Sebastian ;
Sandoval, Cristian ;
Araya-Letelier, Gerardo ;
Inzunza, Ernesto ;
Milani, Gabriele .
JOURNAL OF BUILDING ENGINEERING, 2021, 38 (38)
[10]   Shear response of partially-grouted reinforced masonry walls with a central opening: Testing and detailed micro-modelling [J].
Calderon, Sebastian ;
Sandoval, Cristian ;
Arnau, Oriol .
MATERIALS & DESIGN, 2017, 118 :122-137