Effect of different surface pre-treatments and luting materials on shear bond strength to PEEK

被引:199
作者
Schmidlin, Patrick R. [1 ]
Stawarczyk, Bogna [2 ]
Wieland, Marco [3 ]
Attin, Thomas [1 ]
Haemmerle, Christoph H. F. [2 ]
Fischer, Jens [2 ]
机构
[1] Univ Zurich, Ctr Dent & Oral Med, Clin Prevent Dent Periodontol & Cariol, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Ctr Dent & Oral Med, Clin Fixed & Removable Prosthodont & Dent Mat Sci, CH-8032 Zurich, Switzerland
[3] Straumann AG, Basel, Switzerland
关键词
PEEK; Composite resin; Bonding; Shear bond strength; SEM; ADHESIVE RESIN CEMENTS; DENTIN;
D O I
10.1016/j.dental.2010.02.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. To assess the bonding potential of a universal composite resin cement and an adhesive/composite system to differently pre-treated PEEK surfaces. Methods. One hundred and fifty PEEK disks were embedded in epoxy resin, polished (P4000 grit) and treated as follows (n = 30/group): (A) no treatment, (B) acid etching with sulfuric acid (98%) for 1 min, (C) sandblasting for 10 s with 50 mu m alumina, (D) sandblasting for 10 s with 110 mu m alumina and (E) silica coating using the Rocatec system (3M ESPE). Polished and sandblasted (50 mu m alumina) cp titanium (grade 4) served as a control. Acrylic hollow cylinder were either luted with a universal composite resin cement (RelyX Unicem) or an unfilled resin (Heliobond) and a hybrid composite (Tetric) to the specimens. Bond strength was measured in a shear test and failure modes were assessed. Statistic analysis was performed with one-way ANOVA followed by a post hoc Scheffe test and unpaired t-tests. Results. With the universal composite resin cement, no bond could be established on any PEEK surfaces, except specimens etched with sulfuric acid (19.0 +/- 3.4MPa). Shear bond strength to titanium was significantly lower (8.7 +/- 2.8 MPa, p < 0.05). Applying the adhesive/composite system, shear bond strength values on pre-treated PEEK ranged from 11.5 +/- 3.2 MPa (silica coating) to 18.2 +/- 5.4 MPa (acid etched) with no statistically significant differences (p > 0.05). No bond was obtained on the polished surface. Significance. Bonding to PEEK is possible when using a bonding system. No adherence can be achieved with the tested universal composite resin cement except on an etched surface. The results strongly encourage further research in PEEK application in dentistry. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:553 / 559
页数:7
相关论文
共 12 条
[1]   Marginal adaptation in dentin of a self-adhesive universal resin cement compared with well-tried systems [J].
Behr, M ;
Rosentritt, M ;
Regnet, T ;
Lang, R ;
Handel, G .
DENTAL MATERIALS, 2004, 20 (02) :191-197
[2]   Shear bond strength of resin cements to human dentin [J].
Holderegger, Claudia ;
Sailer, Irena ;
Schuhmacher, Caroline ;
Schlaepfer, Ragna ;
Haemmerle, Christoph ;
Fischer, Jens .
DENTAL MATERIALS, 2008, 24 (07) :944-950
[3]   Influence of different adhesive resin cements on the fracture strength of aluminum oxide ceramic posterior crowns [J].
Komine, F ;
Tomic, M ;
Gerds, T ;
Strub, JR .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (04) :359-364
[4]   PEEK biomaterials in trauma, orthopedic, and spinal implants [J].
Kurtz, Steven M. ;
Devine, John N. .
BIOMATERIALS, 2007, 28 (32) :4845-4869
[5]  
May R., 1988, ENCY POLYM SCI ENG, P313
[6]   Adhesion and growth of CaCo2 cells on surface-modified PEEK substrata [J].
Noiset, O ;
Schneider, YJ ;
Marchand-Brynaert, J .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (07) :767-786
[7]   Chemical micropatterning of polymeric cell culture substrates using low-pressure hydrogen gas discharge plasmas [J].
Ohl, A ;
Schröder, K ;
Keller, D ;
Meyer-Plath, A ;
Bienert, H ;
Husen, B ;
Rune, GM .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (12) :747-754
[8]   In vitro shear bond strength of cementing agents to fixed prosthodontic restorative materials [J].
Piwowarczyk, A ;
Lauer, HC ;
Sorensen, JA .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (03) :265-273
[9]  
Radovic I, 2008, J ADHES DENT, V10, P251
[10]  
Rigby R., 1985, Engineering Thermoplastics: Properties and Applications, P299