Short-term Measurements of Indoor Environmental Quality in Selected Offices - Case Study

被引:0
作者
Meciarova, Ludmila [1 ]
Vilcekova, Silvia [1 ]
Burdov, Eva Kridlova [1 ]
Apostoloski, Ilija Zoran [1 ]
Kosicanova, Danica [1 ]
机构
[1] Tech Univ Kosice, Fac Civil Engn, Kosice, Slovakia
来源
10TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (10TH ICEE) | 2017年
关键词
indoor environment; office; elementary school; health; VOLATILE ORGANIC-COMPOUNDS; PARTICULATE MATTER; BUILDINGS; AIR; EMISSIONS; WORKERS; CLIMATE; FIELD;
D O I
10.3846/enviro.2017.266
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Decent quality of indoor air is important for health and wellbeing of building users. We live, work and study in indoors of various types of buildings. Often people are exposed to pollutants at higher concentrations than these that occur outdoors. Continual investigation of indoor air quality is needed for ensuring comfort and healthy environment. Measuring and analysis of occurrence of physical, chemical and biological factors is the first step for suggestion of optimization measures. Inside school buildings there are often inadequate indoor climate conditions such as thermal comfort parameters or ventilation. The aim of this study was determination of indoor environmental quality in selected offices in the building of elementary school in Slovakia. The values of operative temperature were not within the optimum range of values for the warm period of the year in one of the monitored offices. The intensity of illumination was lower in the two offices. Low levels of particulate matters were measured except the one office where permissible value was exceeded by 7.6%.
引用
收藏
页数:7
相关论文
共 28 条
[1]  
[Anonymous], 2016, IARC MONOGRAPHS IARC
[2]  
[Anonymous], 2016, PERFUMER FLAVORIST
[3]  
[Anonymous], 1998, ISO 7726
[4]  
ATSDR, 2016, PUBL HLTH STAT NAPHT
[5]   CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR - A REVIEW [J].
BROWN, SK ;
SIM, MR ;
ABRAMSON, MJ ;
GRAY, CN .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :123-134
[6]  
Budaiova Z., 2015, HLTH BUILDINGS EUROP
[7]  
Budaiova Z., 2015, P 14 INT C ENV SCI T
[8]  
Budaiova Zdenka., 2015, SSP - JOURNAL OF CIVIL ENGINEERING, V10, P37, DOI [10.1515/sspjce-2015-0004, DOI 10.1515/SSPJCE-2015-0004]
[9]   Indoor/outdoor particulate matter number and mass concentration in modern offices [J].
Chatoutsidou, Sofia Eirini ;
Ondracek, Jakub ;
Tesar, Ondrej ;
Torseth, Kjetil ;
Zdimal, Vladimir ;
Lazaridis, Mihalis .
BUILDING AND ENVIRONMENT, 2015, 92 :462-474
[10]   Combining performance and implementability of model-based controllers for indoor climate control in office environments [J].
Gruber, Mattias ;
Truschel, Anders ;
Dalenback, Jan-Olof .
BUILDING AND ENVIRONMENT, 2014, 82 :228-236