Does the absorbable fibrin adhesive bandage facilitate partial nephrectomy?

被引:28
作者
Cornum, RL
Morey, AF
Harris, R
Gresham, V
Daniels, R
Knight, RW
Beall, D
Pusateri, A
Holcomb, J
MacPhee, M
机构
[1] Brooke Army Med Ctr, Urol Serv, Ft Sam Houston, TX 78234 USA
[2] Brooke Army Med Ctr, Dept Pathol, Ft Sam Houston, TX 78234 USA
[3] Brooke Army Med Ctr, Dept Radiol, Ft Sam Houston, TX 78234 USA
[4] USA, Inst Surg Res, Ft Sam Houston, TX 78234 USA
[5] Amer Red Cross, Rockville, MD USA
关键词
hemostasis; fibrin adhesive; nephrectomy;
D O I
10.1016/S0022-5347(05)67328-4
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the ability of the absorbable fibrin adhesive bandage (AFAB), a prototype product comprising lyophilized fibrinogen and thrombin on a Vicryl(TM) mesh backing, to seal the collecting system and control bleeding after partial nephrectomy. Materials and Methods: Growing female pigs (n = 18) underwent left nephrectomy and a 40% (by length) right lower pole partial nephrectomy. One of three treatments was immediately applied: Conventional-closure of the collecting system, ligation of visible segmental vessels, application of Surgicel(TM) with bolstering sutures to the renal capsule; AFAB-application of up to two 4 x 4-inch AFABs held under pressure for 60 seconds; Placebo-application of a hemostatically inert Vicryl(TM) bandage, visually identical to the AFAB. Blood loss and ischemic and total operative times were recorded, and abdominal computerized tomography (CT) was performed on postoperative day 6. Animals were sacrificed at 6 weeks to evaluate the remaining renal mass histologically. Results: Compared with conventional therapy, use of the AFAB resulted in significantly less bleeding (13 versus 68 mi., p <0.001) and lower operative (7.2 versus 16.3 minutes, p <0.001) and ischemic times (3.4 versus 7.8 minutes, p <0.001). Estimated blood loss in the placebo bandage group was dramatically higher (357 mi., p <0.001). Postoperative CT and histological sectioning suggested that the AFAB produces astable, durable clot and that healing is at least as successful as with conventional treatment. Conclusion: Use of the AFAB facilitated performance of partial nephrectomy by reducing blood loss and ischemic and total operative times. The AFAB appears equivalent to conventional surgery in its ability to seal the collecting system.
引用
收藏
页码:864 / 867
页数:4
相关论文
共 16 条
[1]  
Campbell S C, 1995, Semin Urol Oncol, V13, P281
[2]   COMPLICATIONS OF NEPHRON SPARING SURGERY FOR RENAL TUMORS [J].
CAMPBELL, SC ;
NOVICK, AC ;
STREEM, SB ;
KLEIN, E ;
LICHT, M .
JOURNAL OF UROLOGY, 1994, 151 (05) :1177-1180
[3]   Intraoperative use of the absorbable fibrin adhesive bandage: Long term effects [J].
Cornum, R ;
Bell, J ;
Gresham, V ;
Brinkley, W ;
Beall, D ;
MacPhee, M .
JOURNAL OF UROLOGY, 1999, 162 (05) :1817-1820
[4]  
FABRICIUS PG, 1987, UROL RES, V15, P307
[5]   PARTIAL NEPHRECTOMY FOR INCIDENTAL RENAL-CELL CARCINOMA [J].
HERR, HW .
BRITISH JOURNAL OF UROLOGY, 1994, 74 (04) :431-433
[6]   Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury [J].
Holcomb, J ;
MacPhee, M ;
Hetz, S ;
Harris, R ;
Pusateri, A ;
Hess, J .
ARCHIVES OF SURGERY, 1998, 133 (01) :32-35
[7]   Implications of new dry fibrin sealant technology for trauma surgery [J].
Holcomb, JB ;
Pusateri, AE ;
Hess, JR ;
Hetz, SP ;
Harris, RA ;
Tock, BB ;
Drohan, WN ;
MacPhee, MJ .
SURGICAL CLINICS OF NORTH AMERICA, 1997, 77 (04) :943-&
[8]  
HOLCOMB JB, IN PRESS J TRAUMA
[9]   Nephron-sparing surgery compared with radical nephrectomy for renal tumors: Current indications and results [J].
Indudhara, R ;
Bueschen, AJ ;
Urban, DA ;
Burns, JR ;
Lloyd, LR .
SOUTHERN MEDICAL JOURNAL, 1997, 90 (10) :982-985
[10]   Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: A randomized, blinded, placebo-controlled study [J].
Jackson, MR ;
Friedman, SA ;
Carter, AJ ;
Bayer, V ;
Burge, JR ;
MacPhee, MJ ;
Drohan, WN ;
Alving, BM .
JOURNAL OF VASCULAR SURGERY, 1997, 26 (02) :274-280