Mandibular advancement device and CPAP upon cardiovascular parameters in OSA

被引:69
作者
Dal-Fabbro, Cibele [1 ]
Garbuio, Silverio [1 ]
D'Almeida, Vania [1 ]
Cintra, Fatima D. [1 ]
Tufik, Sergio [1 ]
Bittencourt, Lia [1 ]
机构
[1] Univ Fed Sao Paulo UNIFESP, Dept Psicobiol, BR-04024002 Sao Paulo, Brazil
关键词
Mandibular advancement device; Obstructive sleep apnea; Continuous positive airway pressure; Heart rate variability; Oxidative stress; Blood pressure; POSITIVE AIRWAY PRESSURE; OBSTRUCTIVE SLEEP-APNEA; ORAL APPLIANCE THERAPY; AMBULATORY BLOOD-PRESSURE; INDEPENDENT RISK-FACTOR; OXIDATIVE STRESS; LIPID-PEROXIDATION; TOTAL HOMOCYSTEINE; CONTROLLED TRIAL; VARIABILITY;
D O I
10.1007/s11325-014-0937-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study aims to compare the effects of a mandibular advancement device (MAD) with continuous positive airway pressure (CPAP) treatment for obstructive sleep apnea (OSA) on blood pressure (BP), oxidative stress, and heart rate variability (HRV) in a randomized, crossed-over, single-blind, and controlled trial. Twenty-nine moderate-to-severe adult OSA patients underwent MAD, CPAP, and placebo oral appliance treatment. Polysomnography, Epworth sleepiness scale, 24-h ambulatory BP monitoring, oxidative stress parameters (malondialdehyde, catalase, superoxide dismutase, vitamins C, E, B-6, B-12, folate, homocysteine, uric acid), and HRV were assessed at baseline and after 1 month of each treatment. Diaries were used to evaluate compliance for devices and a pressure-time meter for CPAP. Both active treatments resulted in decreases in apnea and hypopnea index and Epworth sleepiness scale; CPAP showed a greater effect. Frequency of diastolic BP dipping was higher in the MAD group compared with the CPAP group. A significant drop from baseline levels for catalase activity was observed after MAD. For HRV, there was a significant decrease in total power at night with CPAP and MAD compared with POA, and a decrease in index of sleep autonomic variation with MAD compared with baseline levels. Compliance rates were higher with MAD rather than CPAP. Even though CPAP proved to be more effective at attenuating OSA, better compliance with MAD favored the reduction of one of the enzymes which participates in oxidative stress and better autonomic modulation during sleep.
引用
收藏
页码:749 / 759
页数:11
相关论文
共 72 条
[1]   BRAIN CHEMI-LUMINESCENCE AND OXIDATIVE STRESS IN HYPERTHYROID RATS [J].
ADAMO, AM ;
LLESUY, SF ;
PASQUINI, JM ;
BOVERIS, A .
BIOCHEMICAL JOURNAL, 1989, 263 (01) :273-277
[2]   Effects on blood pressure after treatment of obstructive sleep apnoea with a mandibular advancement appliance - a three-year follow-up [J].
Andren, A. ;
Sjoquist, M. ;
Tegelberg, A. .
JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) :719-725
[3]   Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea [J].
Barnes, M ;
McEvoy, RD ;
Banks, S ;
Tarquinio, N ;
Murray, CG ;
Vowles, N ;
Pierce, RJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (06) :656-664
[4]   A Randomized controlled trial of continuous positive airway pressure in mild obstructive sleep apnea [J].
Barnes, M ;
Houston, D ;
Worsnop, CJ ;
Neill, AM ;
Mykytyn, IJ ;
Kay, A ;
Trinder, J ;
Saunders, NA ;
McEvoy, RD ;
Pierce, RJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (06) :773-780
[5]   Effect of nasal continuous positive airway pressure treatment on blood pressure in patients with obstructive sleep apnea [J].
Becker, HF ;
Jerrentrup, A ;
Ploch, T ;
Grote, L ;
Penzel, T ;
Sullivan, CE ;
Peter, JH .
CIRCULATION, 2003, 107 (01) :68-73
[6]   Portuguese-language version of the Epworth sleepiness scale: validation for use in Brazil [J].
Bertolazi, Alessandra Naimaier ;
Fagondes, Simone Chaves ;
Hoff, Leonardo Santos ;
Pedro, Vinicius Dallagasperina ;
Menna Barreto, Sergio Saldanha ;
Johns, Murray W. .
JORNAL BRASILEIRO DE PNEUMOLOGIA, 2009, 35 (09) :877-883
[7]  
Bittencourt Lia Rita Azeredo, 2005, Rev. Bras. Psiquiatr., V27, P16, DOI 10.1590/S1516-44462005000500004
[8]   The variability of the apnoea-hypopnoea index [J].
Bittencourt, LRA ;
Suchecki, D ;
Tufik, S ;
Peres, C ;
Togeiro, SM ;
Bagnato, MDC ;
Nery, LE .
JOURNAL OF SLEEP RESEARCH, 2001, 10 (03) :245-251
[9]  
Bittencourt LRA, 2008, DIAGNOSTICO TRATAMEN
[10]  
BONNET M, 1993, SLEEP, V16, P748