High-quality low-dose cardiovascular computed tomography (CCT) in pediatric patients using a 64-slice scanner

被引:5
作者
Cannao, Paola Maria [1 ]
Secchi, Francesco [1 ]
Ali, Marco [2 ]
D'Angelo, Ida Daniela [3 ]
Scarabello, Marco [3 ]
Di Leo, Giovanni [1 ]
Sardanelli, Francesco [1 ,4 ]
机构
[1] IRCCS Policlin San Donato, Radiol Unit, Donato Milanese, Italy
[2] Univ Milan, PhD Course Integrat Biomed Res, Milan, Italy
[3] Univ Milan, Postgrad Sch Radiodiagnost, Milan, Italy
[4] Univ Milan, Dipartimento Sci Biomed Salute, San Donato Milanese, Italy
关键词
Cardiovascular computed tomography; pediatric computed tomography; congenital heart diseases; radiation dose; 64-slice CT; image quality; DIAGNOSTIC CARDIAC-CATHETERIZATION; CONGENITAL HEART-DISEASE; TEST BOLUS; CT; ANGIOGRAPHY; REGISTRY;
D O I
10.1177/0284185117752981
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Cardiovascular computed tomography (CCT) technology is rapidly advancing allowing to perform good quality examinations with a radiation dose as low as 1.2 mSv. However, latest generation scanners are not available in all centers. Purpose: To estimate radiation dose and image quality in pediatric CCT using a standard 64-slice scanner. Material and Methods: A total of 100 patients aged 6.9 +/- 5.4 years (mean +/- standard deviation) who underwent a 64-slice CCT scan using 80, 100, or 120 kVp, were retrospectively evaluated. Radiation effective dose was calculated on the basis of the dose length product. Two independent readers assessed the image quality through signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and a qualitative score (3 = very good, 2 = good, 1 = poor). Non-parametric tests were used. Results: Fifty-five exams were not electrocardiographically (ECG) triggered, 20 had a prospective ECG triggering, and 25 had retrospective ECG triggering. The median effective dose was 1.3 mSv (interquartile range [IQR] =0.8-2.7 mSv). Median SNR was 30.6 (IQR = 23.4-33.6) at 120 kVp, 29.4 (IQR= 23.7-34.8) at 100 kVp, and 24.7 (IQR= 19.4-34.3) at 80 kVp. Median CNR was 21.0 (IQR= 14.8-24.4), 19.1 (IQR= 15.6-23.9), and 25.3 (IQR= 19.4-33.4), respectively. Image quality was very good, good, and poor in 56, 39, and 5 patients, respectively. No significant differences were found among voltage groups for SNR (P = 0.486), CNR (P= 0.336), and subjective image quality (P= 0.296). The inter-observer reproducibility was almost perfect (kappa =0.880). Conclusion: High-quality pediatric CCT can be performed using a 64-slice scanner, with a radiation effective dose close to 2 mSv in about 50% of the cases.
引用
收藏
页码:1247 / 1253
页数:7
相关论文
共 21 条
[1]   Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization [J].
Arnold, Raoul ;
Ley, Sebastian ;
Ley-Zaporozhan, Julia ;
Eichhorn, Joachim ;
Schenk, Jens-Peter ;
Ulmer, Herbert ;
Kauczor, Hans-Ulrich .
PEDIATRIC RADIOLOGY, 2007, 37 (10) :998-1006
[2]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[3]   Italian Registry of Cardiac Computed Tomography [J].
Cademartiri, Filippo ;
Di Cesare, Ernesto ;
Francone, Marco ;
Ballerini, Giovanni ;
Ligabue, Guido ;
Maffei, Erica ;
Romagnoli, Andrea ;
Argiolas, Giovanni Maria ;
Russo, Vincenzo ;
Buffa, Vitaliano ;
Marano, Riccardo ;
Guzzetta, Maria ;
Belgrano, Manuel ;
Carbone, Iacopo ;
Macarini, Luca ;
Borghi, Claudia ;
Di Renzi, Paolo ;
Barile, Vicenzo ;
Patriarca, Lucia .
RADIOLOGIA MEDICA, 2015, 120 (10) :919-929
[4]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[5]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[7]   Radiation Dose Reduction in Pediatric Cardiac Computed Tomography: Experience from a Tertiary Medical Center [J].
Ghoshhajra, Brian B. ;
Lee, Ashley M. ;
Engel, Leif-Christopher ;
Celeng, Csilla ;
Kalra, Mannudeep K. ;
Brady, Thomas J. ;
Hoffmann, Udo ;
Westra, Sjirk J. ;
Abbara, Suhny .
PEDIATRIC CARDIOLOGY, 2014, 35 (01) :171-179
[8]   Computed Tomography Imaging in Patients with Congenital Heart Disease Part I: Rationale and Utility. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT) [J].
Han, B. Kelly ;
Rigsby, Cynthia K. ;
Hlavacek, Anthony ;
Leipsic, Jonathon ;
Nicol, Edward D. ;
Siegel, Marilyn J. ;
Bardo, Dianna ;
Abbara, Suhny ;
Ghoshhajra, Brian ;
Lesser, John R. ;
Raman, Subha ;
Crean, Andrew M. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (06) :475-492
[9]   Practical Strategies for Low Radiation Dose Cardiac Computed Tomography [J].
Henzler, Thomas ;
Hanley, Michael ;
Arnoldi, Elisabeth ;
Bastarrika, Gorka ;
Schoepf, U. Joseph ;
Becker, Hans-Christoph .
JOURNAL OF THORACIC IMAGING, 2010, 25 (03) :213-220
[10]   Perioperative evaluation of airways in patients with arch obstruction and intracardiac defects [J].
Jhang, Won Kyoung ;
Park, Jeong-Jun ;
Seo, Dong-Man ;
Goo, Hyun Woo ;
Gwak, MiJeung .
ANNALS OF THORACIC SURGERY, 2008, 85 (05) :1753-1758