Scale-Up Study on the Performance of the Asymmetric Rotating Impeller Extraction Column

被引:11
作者
Hendre, Nilesh, V [1 ]
Hinge, Shruti P. [1 ]
Patwardhan, Ashwin W. [1 ]
机构
[1] Inst Chem Technol, Dept Chem Engn, Mumbai 400019, Maharashtra, India
关键词
MASS-TRANSFER COEFFICIENTS; DROP SIZE DISTRIBUTION; DISPERSED PHASE HOLDUP; FLOODING CHARACTERISTICS; PREDICTION; LIQUID; DISC; MODEL; PARAMETERS; CONTACTOR;
D O I
10.1021/acs.iecr.1c00353
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present work, hydrodynamics and mass transfer performance of the asymmetric rotating impeller column (ARIC) of different scales, that is, ARIC 1 (I.D. = 0.1 m), ARIC 2 (I.D. = 0.22 m), and ARIC 3 (I.D. = 0.3 m), have been investigated. The liquid-liquid system used in the present study is phosphoric acid containing metal ions and the organo-phosphorous solvent. The effect of different operating conditions on regime transition in ARIC of different scales has been analyzed. Correlations have been developed for the prediction of holdup and drop size in the ARIC of different scales. The average absolute relative error values in the prediction of holdup and drop size using these correlations are 10 and 9%, respectively. An increase in the height of transfer unit is observed with an increase in throughput and column diameter. The results indicate that adequate design and scale-up of extraction columns can be carried out based on geometric similarity.
引用
收藏
页码:5945 / 5963
页数:19
相关论文
共 43 条
[1]   Mass transfer studies in a horizontal pulsed sieve-plate column for uranium extraction by tri-n-octylamine using axial dispersion model [J].
Amani, Pouria ;
Safdari, Jaber ;
Gharib, Ahmad ;
Badakhshan, Hossein ;
Mallah, Mohammad H. .
PROGRESS IN NUCLEAR ENERGY, 2017, 98 :71-84
[2]   Continuous Extraction of Europium(III) by Ionic Liquid in the Rotating Disk Column with an Asymmetrical Structure Aimed at the Evaluation of Reactive Mass Transfer [J].
Asadollahzadeh, Mehdi ;
Torkaman, Rezvan ;
Torab-Mostaedi, Meisam .
ACS OMEGA, 2020, 5 (30) :18700-18709
[3]   Estimation of Performance with the Two Truncated Probability Density Functions, Case Study: Using Mixco Column to Extract Samarium and Gadolinium [J].
Asadollahzadeh, Mehdi ;
Torkaman, Rezvan ;
Torab-Mostaedi, Meisam ;
Moazami, Farzad .
SEPARATION SCIENCE AND TECHNOLOGY, 2021, 56 (07) :1241-1252
[4]   Study on the feasibility of using a pilot plant Scheibel extraction column for the extraction and separation of lanthanum and cerium from aqueous solution [J].
Asadollahzadeh, Mehdi ;
Torkaman, Rezvan ;
Torab-Mostaedi, Meisam .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2020, 37 (02) :322-331
[5]   Use of axial dispersion model for determination of Sherwood number and mass transfer coefficients in a perforated rotating disc contactor [J].
Asadollahzadeh, Mehdi ;
Hemmati, Alireza ;
Torab-Mostaedi, Meisam ;
Shirvani, Mansour ;
Ghaemi, Ahad ;
Mohsenzadeh, ZahraSadat .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2017, 25 (01) :53-61
[6]   Holdup and flooding measurements in an asymmetric rotating disc column [J].
Asadollahzadeh, Mehdi ;
Torab-Mostaedi, Meisam ;
Torkaman, Rezvan .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 109 :97-103
[7]   A new model for prediction of drop size distribution in a liquid-liquid extraction column [J].
Asadollahzadeh, Mehdi ;
Torab-Mostaedi, Meisam ;
Torkaman, Rezvan ;
Safdari, Jaber .
RSC ADVANCES, 2016, 6 (86) :82496-82504
[8]   Experimental investigation of dispersed phase holdup and flooding characteristics in a multistage column extractor [J].
Asadollahzadeh, Mehdi ;
Torab-Mostaedi, Meisam ;
Shahhosseini, Shahrokh ;
Ghaemi, Ahad .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 105 :177-187
[9]   Using maximum entropy approach for prediction of drop size distribution in a pilot plant multi-impeller extraction contactor [J].
Asadollahzadeh, Mehdi ;
Torab-Mostaedi, Meisam ;
Shahhosseini, Shahrokh ;
Ghaemi, Ahad .
RSC ADVANCES, 2015, 5 (116) :95967-95980
[10]   EFFECT OF MASS-TRANSFER ON FLOODING AND HOLDUP IN A KARR COLUMN [J].
BENSALEM, A ;
STEINER, L ;
HARTLAND, S .
SOLVENT EXTRACTION AND ION EXCHANGE, 1985, 3 (05) :697-722