Pore-scale measurements of solute breakthrough using microfocus X-ray computed tomography

被引:70
|
作者
Clausnitzer, V [1 ]
Hopmans, JW [1 ]
机构
[1] Univ Calif Davis, Dept Land Air & Water Resources, Davis, CA 95616 USA
关键词
D O I
10.1029/2000WR900076
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
X-ray computed tomography (CT) offers distinct advantages to study fundamental physical processes of water movement and contaminant transport in porous media. Tomography provides nondestructive and noninvasive cross-sectional or three-dimensional representations of porous media and has the potential to measure phase distribution and species concentration at the pore scale. Sources of error are discussed for the application of industrial microfocus CT to quantitative studies of flow and transport. Specifically, effective resolution and measurement uncertainties due to photon randomness are considered for a miscible displacement experiment. A calibration method for the measurement of solute concentration is proposed that accounts for the effect of beam hardening, which is characteristic for polychromatic industrial X-ray sources. The results of an X-ray microfocus CT experiment are presented, emphasizing the need to correct for beam hardening and describing the inherent spatial variability of solute breakthrough through a glass-bead porous medium with an effective spatial resolution of approximately 85 mu m.
引用
收藏
页码:2067 / 2079
页数:13
相关论文
共 50 条
  • [1] Radioscopy and computed tomography for failure analysis using microfocus X-ray
    Bossi, RH
    Cross, DA
    Mickelsen, RA
    NONDESTRUCTIVE EVALUATION OF MATERIALS AND COMPOSITES, 1996, 2944 : 13 - 20
  • [2] Microfocus x-ray inspection with radioscopy and computed tomography
    Nuding, W
    Sauerwein, C
    Schekira, S
    Wiacker, H
    EUROMAT 97 - PROCEEDINGS OF THE 5TH EUROPEAN CONFERENCE ON ADVANCED MATERIALS AND PROCESSES AND APPLICATIONS: MATERIALS, FUNCTIONALITY & DESIGN, VOL 4: CHARACTERIZATION AND PRODUCTION/DESIGN, 1997, : 159 - 162
  • [3] Particle based method and X-ray computed tomography for pore-scale flow characterization in VRFB electrodes
    Maggiolo, Dario
    Zanini, Filippo
    Picano, Francesco
    Trovo, Andrea
    Carmignato, Simone
    Guarnieri, Massimo
    ENERGY STORAGE MATERIALS, 2019, 16 : 91 - 96
  • [4] Formation damage evaluation of a sandstone reservoir via pore-scale X-ray computed tomography analysis
    Yang, Yongfei
    Li, Yingwen
    Yao, Jun
    Zhang, Kai
    Iglauer, Stefan
    Luquot, Linda
    Wang, Zengbao
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2019, 183
  • [5] Pore-scale contact angle measurements at reservoir conditions using X-ray microtomography
    Andrew, Matthew
    Bijeljic, Branko
    Blunt, Martin J.
    ADVANCES IN WATER RESOURCES, 2014, 68 : 24 - 31
  • [6] Pore-scale characterization of carbonates using X-ray microtomography
    Arns, CH
    Bauget, F
    Limaye, A
    Sakellariou, A
    Senden, TJ
    Sheppard, AP
    Sok, RM
    Pinczewski, WV
    Bakke, S
    Berge, LI
    Oren, RE
    Knackstedt, MA
    SPE JOURNAL, 2005, 10 (04): : 475 - 484
  • [7] Microstructure observation in deformed geomaterials using microfocus X-ray computed tomography
    Takemura, T
    Oda, A
    Takahashi, A
    X-RAY CT FOR GEOMATERIALS SOILS, CONCRETE, ROCKS, 2004, : 299 - 304
  • [8] Age estimation using microfocus X-ray computed tomography of lower premolars
    Aboshi, H.
    Takahashi, T.
    Komuro, T.
    FORENSIC SCIENCE INTERNATIONAL, 2010, 200 (1-3) : 35 - 40
  • [9] Progress of microfocus X-ray systems for fluoroscopic and computed tomography
    Hirakimoto, A
    Ohnishi, S
    Maeda, H
    Kishi, T
    Shiota, T
    Tamura, T
    Ukita, M
    Fujita, S
    Kamegawa, M
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (08) : 1101 - 1106
  • [10] Pore-scale contact angle measurements of CO2-brine-glass beads system using micro-focused X-ray computed tomography
    Lv, Pengfei
    Liu, Yu
    Jiang, Lanlan
    Song, Yongchen
    Huang, Qingxun
    MICRO & NANO LETTERS, 2016, 11 (09): : 524 - 527