Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection

被引:86
作者
Berger, Tim [1 ,2 ]
Weiss, Gabriel [3 ]
Voetsch, Andreas [4 ]
Arnold, Zsuzsanna [3 ]
Kreibich, Maximilian [1 ,2 ]
Rylski, Bartosz [1 ,2 ]
Krombholz-Reindl, Philipp [4 ]
Winkler, Andreas [4 ]
Mach, Markus [3 ]
Geisler, Daniela [3 ]
Seitelberger, Rainald [4 ]
Siepe, Mathias [1 ,2 ]
Beyersdorf, Friedhelm [1 ,2 ]
Grabenwoeger, Martin [3 ]
Czerny, Martin [1 ,2 ]
Gottardi, Roman [4 ]
机构
[1] Univ Freiburg, Univ Heart Ctr Freiburg, Dept Cardiovasc Surg, Freiburg, Germany
[2] Albert Ludwigs Univ Freiburg, Fac Med, Freiburg, Germany
[3] Hosp Hietzing, Dept Cardiovasc Surg, Vienna, Austria
[4] Paracelsus Med Univ, Landeskrankenhaus Salzburg, Dept Cardiovasc Surg, Muellner Hauptstr 48, A-5020 Salzburg, Austria
关键词
Frozen elephant trunk; Aortic dissection; False lumen thrombosis; DOWNSTREAM AORTA; REPAIR; RECOMMENDATIONS; DIAMETER; LUMEN; RISK;
D O I
10.1093/ejcts/ezz037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex (TM) hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection. METHODS: All consecutive patients [n = 88; median age 59 (49-67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex (TM) device was implanted in 55 patients and the E-vita Open graft in 33 patients. RESULTS: Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex (TM) hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses. CONCLUSIONS: In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.
引用
收藏
页码:572 / 578
页数:7
相关论文
共 16 条
[11]   Multiple factors predict the risk of spinal cord injury after the frozen elephant trunk technique for extended thoracic aortic disease [J].
Katayama, Keijiro ;
Uchida, Naomichi ;
Katayama, Akira ;
Takahashi, Shinya ;
Takasaki, Taiichi ;
Kurosaki, Tatsuya ;
Imai, Katsuhiko ;
Sueda, Taijiro .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (04) :616-620
[12]   The frozen elephant trunk technique for the treatment of acute complicated Type B aortic dissection [J].
Kreibich, Maximilian ;
Berger, Tim ;
Morlock, Julia ;
Kondov, Stoyan ;
Scheumann, Johannes ;
Kari, Fabian A. ;
Rylski, Bartosz ;
Siepe, Matthias ;
Beyersdorf, Friedhelm ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (03) :525-530
[13]   Acute non-A non-B aortic dissection: incidence, treatment and outcome [J].
Rylski, Bartosz ;
Perez, Marta ;
Beyersdorf, Friedhelm ;
Reser, Diana ;
Kari, Fabian A. ;
Siepe, Matthias ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (06) :1111-1117
[14]   Total aortic arch replacement with the frozen elephant trunk procedure in acute DeBakey type I aortic dissections [J].
Shrestha, Malakh ;
Haverich, Axel ;
Martens, Andreas .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 :29-34
[15]   Current status and recommendations for use of the frozen elephant trunk technique: a position paper by the Vascular Domain of EACTS [J].
Shrestha, Malakh ;
Bachet, Jean ;
Bavaria, Joseph ;
Carrel, Thierry P. ;
De Paulis, Ruggero ;
Di Bartolomeo, Roberto ;
Etz, Christian D. ;
Grabenwoeger, Martin ;
Grimm, Michael ;
Haverich, Axel ;
Jakob, Heinz ;
Martens, Andreas ;
Mestres, Carlos A. ;
Pacini, Davide ;
Resch, Tim ;
Schepens, Marc ;
Urbanski, Paul P. ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (05) :759-769
[16]   Evaluation of the downstream aorta after frozen elephant trunk repair for aortic dissections in terms of diameter and false lumen status [J].
Weiss, Gabriel ;
Santer, David ;
Dumfarth, Julia ;
Pisarik, Harald ;
Harrer, Marie Luise ;
Folkmann, Sandra ;
Mach, Markus ;
Moidl, Reinhard ;
Grabenwoger, Martin ;
Oberwalder, P. ;
Melissano, G. ;
Shinn, S. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (01) :118-124