Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection

被引:86
作者
Berger, Tim [1 ,2 ]
Weiss, Gabriel [3 ]
Voetsch, Andreas [4 ]
Arnold, Zsuzsanna [3 ]
Kreibich, Maximilian [1 ,2 ]
Rylski, Bartosz [1 ,2 ]
Krombholz-Reindl, Philipp [4 ]
Winkler, Andreas [4 ]
Mach, Markus [3 ]
Geisler, Daniela [3 ]
Seitelberger, Rainald [4 ]
Siepe, Mathias [1 ,2 ]
Beyersdorf, Friedhelm [1 ,2 ]
Grabenwoeger, Martin [3 ]
Czerny, Martin [1 ,2 ]
Gottardi, Roman [4 ]
机构
[1] Univ Freiburg, Univ Heart Ctr Freiburg, Dept Cardiovasc Surg, Freiburg, Germany
[2] Albert Ludwigs Univ Freiburg, Fac Med, Freiburg, Germany
[3] Hosp Hietzing, Dept Cardiovasc Surg, Vienna, Austria
[4] Paracelsus Med Univ, Landeskrankenhaus Salzburg, Dept Cardiovasc Surg, Muellner Hauptstr 48, A-5020 Salzburg, Austria
关键词
Frozen elephant trunk; Aortic dissection; False lumen thrombosis; DOWNSTREAM AORTA; REPAIR; RECOMMENDATIONS; DIAMETER; LUMEN; RISK;
D O I
10.1093/ejcts/ezz037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex (TM) hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection. METHODS: All consecutive patients [n = 88; median age 59 (49-67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex (TM) device was implanted in 55 patients and the E-vita Open graft in 33 patients. RESULTS: Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex (TM) hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses. CONCLUSIONS: In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.
引用
收藏
页码:572 / 578
页数:7
相关论文
共 16 条
[1]   True-lumen and false-lumen diameter changes in the downstream aorta after frozen elephant trunk implantation [J].
Berger, Tim ;
Kreibich, Maximilian ;
Morlock, Julia ;
Kondov, Stoyan ;
Scheumann, Johannes ;
Kari, Fabian A. ;
Rylski, Bartosz ;
Siepe, Matthias ;
Beyersdorf, Friedhelm ;
Czerny, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (02) :375-381
[2]   Technical details making aortic arch replacement a safe procedure using the Thoraflex™ Hybrid prosthesis [J].
Czerny, Martin ;
Rylski, Bartosz ;
Kari, Fabian A. ;
Kreibich, Maximilian ;
Morlock, Julia ;
Scheumann, Johannes ;
Kondov, Stoyan ;
Suedkamp, Michael ;
Siepe, Matthias ;
Beyersdorf, Friedhelm .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 :15-19
[3]   When and how to replace the aortic arch for type A dissection [J].
Di Bartolomeo, Roberto ;
Leone, Alessandro ;
Di Marco, Luca ;
Pacini, Davide .
ANNALS OF CARDIOTHORACIC SURGERY, 2016, 5 (04) :383-388
[4]   Frozen elephant trunk surgery in acute aortic dissection [J].
Di Bartolomeo, Roberto ;
Pantaleo, Antonio ;
Berretta, Paolo ;
Murana, Giacomo ;
Castrovinci, Sebastiano ;
Cefarelli, Mariano ;
Folesani, Gianluca ;
Di Eusanio, Marco .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 149 (02) :S105-S109
[5]   Acute type A aortic dissection: Rationale and outcomes of extensive repair of the arch and distal aorta [J].
Di Marco, Luca ;
Leone, Alessandro ;
Murana, Giacomo ;
Castelli, Andrea ;
Alfonsi, Jacopo ;
Di Bartolomeo, Roberto ;
Pacini, Davide .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 267 :145-149
[6]   Diagnosis and management of aortic dissection - Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology [J].
Erbel, R ;
Alfonso, F ;
Boileau, C ;
Dirsch, O ;
Eber, B ;
Haverich, A ;
Rakowski, H ;
Struyven, J ;
Radegran, K ;
Sechtem, U ;
Taylor, J ;
Zollikofer, C ;
Klein, WW ;
Mulder, B ;
Providencia, LA .
EUROPEAN HEART JOURNAL, 2001, 22 (18) :1642-1681
[7]   Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury [J].
Flores, J ;
Kunihara, T ;
Shiiya, N ;
Yoshimoto, K ;
Matsuzaki, K ;
Yasuda, K .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (02) :336-342
[8]   One-stage hybrid aortic repair using the frozen elephant trunk in acute DeBakey type I aortic dissection [J].
Goebel, Nora ;
Nagib, Ragi ;
Salehi-Gilani, Schahriar ;
Ahad, Samir ;
Albert, Marc ;
Ursulescu, Adrian ;
Franke, Ulrich F. W. .
JOURNAL OF THORACIC DISEASE, 2018, 10 (07) :4195-4203
[9]   Combined surgical and endovascular repair of complex aortic pathologies with a new hybrid prosthesis [J].
Gorlitzer, Michael ;
Weiss, Gabriel ;
Thalmann, Markus ;
Mertikian, Gerard ;
Wislocki, Wojciech ;
Meinhart, Johann ;
Waldenberger, Ferdinand ;
Grabenwoger, Martin .
ANNALS OF THORACIC SURGERY, 2007, 84 (06) :1971-1977
[10]   Thoracic Aortic Aneurysm Expansion Due to Late Distal Stent Graft-Induced New Entry [J].
Janosi, Rolf Alexander ;
Tsagakis, Konstantinos ;
Bettin, Markus ;
Kahlert, Philipp ;
Horacek, Michael ;
Al-Rashid, Fadi ;
Schlosser, Thomas ;
Jakob, Heinz ;
Eggebrecht, Holger ;
Erbel, Raimund .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (02) :E43-E53