A thin cover glass chip for contactless conductivity detection in microchip capillary electrophoresis

被引:49
作者
Chen, Zuanguang [1 ]
Li, Quanwen
Li, Oulian
Zhou, Xie
Lan, You
Wei, Yuanfang
Mo, Jinyuan
机构
[1] Sun Yat Sen Univ, Sch Pharmaceut Sci, Guangzhou 510089, Peoples R China
[2] Sun Yat Sen Univ, Sch Chem & Chem Engineer, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
micro-total analysis systems (mu-TAS); microchip; contactless conductivity detection; capacitively coupled contactless conductivity detection; high frequency conductivity detection;
D O I
10.1016/j.talanta.2006.08.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfabricated thin glass chip for contactless conductivity detection in chip capillary electrophoresis is presented in this contribution. Injection and separation channels were photolithographed and chemically etched on the surface of substrate glass, which was bonded with a thin cover glass (100 mu m) to construct a new microchip. The chip was placed over an independent contactless electrode plate. Owing to the thinness between channel and electrodes, comparatively low excitation voltage (20-110 V in Vp-p) and frequency (40-65 kHz) were suitable, and favorable signal could be obtained. This microchip capillary electrophoresis device was used in separation and detection of inorganic ions, amino acids and alkaloids in amoorcorn tree bark and golden thread in different buffer solutions. The detection limit of potassium ion was down to 10 mu mol/L. The advantages of this microchip system exist in the relative independence between the microchip and the detection electrodes. It is convenient to the replacement of chip and other operations. Detection in different position of the channel would also be available. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1944 / 1950
页数:7
相关论文
共 50 条
[31]   Recent applications of conductivity detection in capillary and chip electrophoresis [J].
Solinova, Veronika ;
Kasicka, Vasclav .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (12) :1743-1762
[32]   Quantification of lactate in synovia by microchip with contactless conductivity detection [J].
Song, Zhirui ;
Xu, Yue ;
Chen, Zuanguang ;
Yang, Jianping ;
Li, Xinchun ;
Zhang, Zhiguang .
ANALYTICAL BIOCHEMISTRY, 2013, 434 (01) :73-77
[33]   Detection of inorganic ions on a capillary electrophoresis microchip using a conductivity technique [J].
Petkovic-Duran, K. ;
Zhu, Y. ;
Swallow, A. ;
Noui-Mehidi, N. ;
Leech, P. ;
Glenn, F. .
BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING III, 2007, 6416
[34]   Optimization of separation of heavy metals by capillary electrophoresis with contactless conductivity detection [J].
Lau, Hiu Fung ;
Quek, Ngee Mian ;
Law, Wai Siang ;
Zhao, Jian Hong ;
Hauser, Peter C. ;
Li, Sam Fong Yau .
ELECTROPHORESIS, 2011, 32 (10) :1190-1194
[35]   Application of capillary electrophoresis with capacitively contactless conductivity detection for biomedical analysis [J].
Elbashir, Abdalla A. ;
Osman, Abdelbagi ;
Elawad, Mohammed ;
Ziyada, Abobakr K. ;
Aboul-Enein, Hassan Y. .
ELECTROPHORESIS, 2024, 45 (5-6) :400-410
[36]   Determination of salbutamol sulfate in medicaments by capillary electrophoresis with contactless conductivity detection [J].
Chen Changguo ;
Li Hong ;
Fan Yujing .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (02) :137-140
[37]   Contactless conductivity detector array for capillary electrophoresis [J].
Stojkovic, Marko ;
Koenka, Israel Joel ;
Thormann, Wolfgang ;
Hauser, Peter C. .
ELECTROPHORESIS, 2014, 35 (04) :482-486
[38]   A simplified poly(dimethylsiloxane) capillary electrophoresis microchip integrated with a low-noise contactless conductivity detector [J].
Liu, Benyan ;
Zhang, Yi ;
Mayer, Dirk ;
Krause, Hans-Joachim ;
Jin, Qinghui ;
Zhao, Jianlong ;
Offenhaeusser, Andreas .
ELECTROPHORESIS, 2011, 32 (6-7) :699-704
[39]   Dual detection for non-aqueous capillary electrophoresis combining contactless conductivity detection and mass spectrometry [J].
Beutner, Andrea ;
Scherer, Beate ;
Matysik, Frank-Michael .
TALANTA, 2018, 183 :33-38
[40]   Determination of carnitine in food and food supplements by capillary electrophoresis with contactless conductivity detection [J].
Pormsila, Worapan ;
Kraehenbuehl, Stephan ;
Hauser, Peter C. .
ELECTROPHORESIS, 2010, 31 (13) :2186-2191