Simultaneous transesophageal cardioversion and echocardiography: Feasibility and safety

被引:1
|
作者
Mischke, Karl
Schimpf, Thomas
Winograd, Ron
Knackstedt, Christian
Zarse, Markus
Plisiene, Jurgita
Hanrath, Peter
Kelm, Malte
Schauerte, Patrick
机构
[1] Rhein Westfal TH Aachen, Dept Cardiol, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Dept Gastroenterol, Aachen, Germany
关键词
atrial fibrillation; cardioversion; transesophageal echocardiography;
D O I
10.1016/j.hrthm.2006.11.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Transesophageal echocardiography (TEE) is routinely used to exclude atrial thrombus prior to cardioversion of atrial fibrillation (AF). Because the TEE probe Lies adjacent to the atria, cardioversion using an electrode attached to the TEE probe should allow for immediate low-energy transesophageat cardioversion. OBJECTIVE The purpose of this study was to evaluate a cardioversion electrode sheath that can be affixed to conventional TEE probes for simultaneous thrombus exclusion and cardioversion of AF. METHODS A thin electrode was integrated into a latex or polyurethane sheath covering a conventional TEE probe. TEE thrombus exclusion and biphasic transesophageat cardioversion using a step-up protocol were performed during deep sedation. Esophagoscopy was performed immediately after cardioversion and after 1 week. RESULTS TEE was performed in 27 patients. One patient showed left atrial thrombi. Transesophageal cardioversion was successful in 25 of the remaining 26 patients. Mean atrial cardioversion threshold was 63 +/- 48 J. Transesophageal cardioversion restored sinus rhythm in two patients with unsuccessful transthoracic cardioversion. Transesophageal cardioversion in deep sedation was well tolerated. Esophagoscopy revealed slight mucosal damage in three patients at the site of shock application; two of these patients showed signs of gastroesophageal reflux disease. Mucosal damage unrelated to the site of shock delivery was noted in three patients. CONCLUSION Atrial thrombus exclusion and transesophageal cardioversion of AF via a disposable cardioversion sheath offers the opportunity to perform transesophageal cardioversion and TEE thrombus exclusion during one sedation. It may not be suitable for use in patients with gastroesophageal reflux disease. Transesophageal cardioversion may establish sinus rhythm in selected patients refractory to transthoracic cardioversion.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 50 条
  • [21] Cardioversion safety in patients with nonvalvular atrial fibrillation: which patients can be spared transesophageal echocardiography?
    Providencia, Rui
    Faustino, Ana
    Paiva, Luis
    Trigo, Joana
    Botelho, Ana
    Nascimento, Jose
    Leitao-Marques, Antonio M.
    BLOOD COAGULATION & FIBRINOLYSIS, 2012, 23 (07) : 597 - 602
  • [22] Safety of transesophageal echocardiography-guided electrical cardioversion in patients with atrial fibrillation and inadequate anticoagulation
    Zaprutko, Joanna
    Baszko, Artur
    Michalak, Michal
    Kochman, Karol
    Szymanski, Radoslaw
    Klopocki, Jan
    Nowicka, Anna
    Dankowski, Rafal
    Michalski, Marek
    Kalmucki, Piotr
    Szyszka, Andrzej
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2017, 127 (7-8): : 524 - 531
  • [23] Safety and efficacy of enoxaparin strategy compared with unfractionated heparin strategy for cardioversion of atrial fibrillation using transesophageal echocardiography: Preliminary results from the assessment of cardioversion using transesophageal echocardiography (ACUTE) II study
    Klein, AL
    Jasper, SE
    Apperson-Hansen, C
    Lieber, EA
    Katz, WE
    Malouf, JF
    Stoddard, MF
    CIRCULATION, 2005, 112 (17) : U434 - U434
  • [24] Pediatric Three-Dimensional Transesophageal Echocardiography: Safety and Feasibility in Young Patients
    Kiener, Alexander
    Doan, Tam T.
    Nguyen, Minh B.
    Mejia, A. Sanchez
    Pignatelli, Ricardo
    Sachdeva, Shagun
    Parthiban, Anitha
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2024, 37 (06) : 647 - 649
  • [25] Feasibility, utility, and safety of fully incorporating transesophageal echocardiography into emergency medicine practice
    Reardon, Robert F.
    Chinn, Elliott
    Plummer, Dave
    Laudenbach, Andrew
    Fisher, Andie Rowland
    Smoot, Will
    Lee, Daniel
    Novik, Joseph
    Wagner, Barrett
    Kaczmarczyk, Chris
    Moore, Johanna
    Thompson, Emily
    Tschautscher, Craig
    Dunphy, Teresa
    Pahl, Thomas
    Puskarich, Michael A.
    Miner, James R.
    ACADEMIC EMERGENCY MEDICINE, 2022, 29 (03) : 334 - 343
  • [26] THE SAFETY OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE ELDERLY
    STODDARD, MF
    LONGAKER, RA
    SMITH, JA
    HARVEY, D
    SHEPHERD, M
    AMERICAN HEART JOURNAL, 1993, 125 (05) : 1358 - 1362
  • [27] SAFETY OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE ELDERLY
    STODDARD, MF
    LONGAKER, RA
    CLINICAL RESEARCH, 1992, 40 (04): : A834 - A834
  • [28] In Situ Transesophageal Echocardiography During Electrical Cardioversion in Patients With Atrial Fibrillation-Safety and Echocardiographic Findings
    Tabrizi, Mehrnoush Toufan
    Girardo, Marlene
    Naqvi, Tasneem Z.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2024, 37 (04) : 420 - 427
  • [29] Transesophageal echocardiography-guided approach to cardioversion of atrial fibrillation
    Leung, DY
    Grimm, RA
    Klein, AL
    PROGRESS IN CARDIOVASCULAR DISEASES, 1996, 39 (01) : 21 - 32
  • [30] Transesophageal echocardiography before cardioversion shock for supraventricular rhythm disorders
    Tribouilloy, C
    Lucas, G
    Rey, JL
    Trojette, F
    Gallet, B
    Choquet, D
    Lesbre, JP
    PRESSE MEDICALE, 1998, 27 (03): : 106 - 109