Trans-Thrombus Blood Pressure Effects in Abdominal Aortic Aneurysms

被引:16
作者
Meyer, Clark A. [1 ]
Guivier-Curien, Carine [1 ]
Moore, James E., Jr. [2 ]
机构
[1] Equipe Biomecan Cardiovasc, IRPHE, CNRS, UMR 6594, F-13451 Marseille, France
[2] Texas A&M Univ, Dept Biomed Engn, Zachry Engn Ctr, College Stn, TX 77843 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 07期
关键词
INTRALUMINAL THROMBUS; WALL STRESS; FAILURE PROPERTIES; RUPTURE; IDENTIFICATION;
D O I
10.1115/1.4001253
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
How much and how the thrombus supports the wall of an abdominal aortic aneurysm (AAA) is unclear While some previous studies have indicated that thrombus lacks the mechanical integrity to support much load compared with the aneurysm wall, others have shown that removing thrombus in computational AAA models drastically changes aneurysm wall stress. Histopathological studies have shown that thrombus properties vary through the thickness and it can be porous. The goal of this study is to explore the variations in thrombus properties, including the ability to isolate pressure from the aneurysm wall, incomplete attachment, and their effects on aneurysm wall stress, an important parameter in determining risk for rupture. An analytical model comprised of cylinders and two patient specific models were constructed with pressurization boundary conditions applied at the lumen or the thrombus/aneurysm wall interface (to simulate complete transmission of pressure through porous thrombus). Aneurysm wall stress was also calculated in the absence of thrombus. The potential importance of partial thrombus attachment was also analyzed. Pressurizing at either surface (lumen versus interface) made little difference to mean von Mises aneurysm wall stress values with thrombus completely attached (3.1% analytic, 1.2% patient specific) while thrombus presence reduced mean von Mises stress considerably (79% analytic, 40-46% patient specific) in comparison to models without it. Peak von Mises stresses were similarly influenced with pressurization surface differing slightly (3.1% analytic, 1.4% patient specific) and reductions in stress by thrombus presence (80% analytic, 28-37% patient specific). The case of partial thrombus attachment was investigated using a cylindrical model in which there was no attachment between the thrombus and aneurysm wall in a small area (10 deg). Applying pressure at the lumen resulted in a similar stress field to fully attached thrombus, whereas applying pressure at the interface resulted in a 42% increase in peak aneurysm wall stress. Taken together these results show that the thrombus can have a wall stress reducing role even if it does not shield the aneurysm wall from direct pressurization as long as the thrombus is fully attached to the aneurysm wall. Furthermore, the potential for porous thrombus to transmit pressure to the interface can result in a considerable increase in aneurysm wall stress in cases of partial attachment. In the search for models capable of accurately assessing the risk for rupture, the nature of the thrombus and its attachment to the aneurysm wall must be carefully assessed. [DOI: 10.1115/1.4001253]
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Low atmospheric pressure is associated with rupture of abdominal aortic aneurysms
    Bown, MJ
    McCarthy, MJ
    Bell, PRF
    Sayers, RD
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 25 (01) : 68 - 71
  • [42] von Willebrand Factor and Prekallikrein in Plasma Are Associated With Thrombus Volume in Abdominal Aortic Aneurysms
    Ghulam, Qasam M.
    Bredahl, Kim K.
    Gram, Jorgen B.
    Lonn, Lars
    Goetze, Jens P.
    Sillesen, Henrik H.
    Eiberg, Jonas P.
    VASCULAR AND ENDOVASCULAR SURGERY, 2016, 50 (06) : 391 - 397
  • [43] The Relationship Between Pulsatile Flow Impingement and Intraluminal Thrombus Deposition in Abdominal Aortic Aneurysms
    Richard J. Lozowy
    David C. S. Kuhn
    Annie A. Ducas
    April J. Boyd
    Cardiovascular Engineering and Technology, 2017, 8 : 57 - 69
  • [44] Association of vortical structures and hemodynamic parameters for regional thrombus accumulation in abdominal aortic aneurysms
    Zambrano, Byron A.
    Gharahi, Hamidreza
    Lim, Chae Young
    Lee, Whal
    Baek, Seungik
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (02)
  • [45] Evaluation of the thrombus of abdominal aortic aneurysms using contrast enhanced ultrasound preliminary results
    Lukasiewicz, Adam
    Garkowski, Adam
    Rutka, Katarzyna
    Janica, Jacek
    Lebkowska, Urszula
    SCIENTIFIC REPORTS, 2016, 6
  • [46] Micromechanical Characterization of Intra-luminal Thrombus Tissue from Abdominal Aortic Aneurysms
    T. Christian Gasser
    Giampaolo Martufi
    Martin Auer
    Maggie Folkesson
    Jesper Swedenborg
    Annals of Biomedical Engineering, 2010, 38 : 371 - 379
  • [47] Variations of dissection properties and mass fractions with thrombus age in human abdominal aortic aneurysms
    Tong, J.
    Cohnert, T.
    Regitnig, P.
    Kohlbacher, J.
    Birner-Gruenberger, R.
    Schriefl, A. J.
    Sommer, G.
    Holzapfel, G. A.
    JOURNAL OF BIOMECHANICS, 2014, 47 (01) : 14 - 23
  • [48] Temporal Changes in Intraluminal Thrombus Volume Within Abdominal Aortic Aneurysms: Implications for Planning Endovascular Aneurysm Sealing
    Paraskevas, Kosmas I.
    Torella, Francesco
    Swaelens, Charles
    England, Andrew
    Chan, Tze Y.
    Shaikh, Usman
    McWilliams, Richard G.
    Fisher, Robert K.
    JOURNAL OF ENDOVASCULAR THERAPY, 2018, 25 (01) : 47 - 51
  • [49] Computational Growth and Remodeling of Abdominal Aortic Aneurysms Constrained by the Spine
    Farsad, Mehdi
    Zeinali-Davarani, Shahrokh
    Choi, Jongeun
    Baek, Seungik
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (09):
  • [50] Growth of common iliac artery aneurysms coexisting with abdominal aortic aneurysms: associated factors and potential role of intraluminal thrombus
    Wang, Yuting
    Zhu, Chengcheng
    Leach, Joseph
    Gasper, Warren
    Saloner, David
    Hope, Michael
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (03) : 703 - 712