Trans-Thrombus Blood Pressure Effects in Abdominal Aortic Aneurysms

被引:16
作者
Meyer, Clark A. [1 ]
Guivier-Curien, Carine [1 ]
Moore, James E., Jr. [2 ]
机构
[1] Equipe Biomecan Cardiovasc, IRPHE, CNRS, UMR 6594, F-13451 Marseille, France
[2] Texas A&M Univ, Dept Biomed Engn, Zachry Engn Ctr, College Stn, TX 77843 USA
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2010年 / 132卷 / 07期
关键词
INTRALUMINAL THROMBUS; WALL STRESS; FAILURE PROPERTIES; RUPTURE; IDENTIFICATION;
D O I
10.1115/1.4001253
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
How much and how the thrombus supports the wall of an abdominal aortic aneurysm (AAA) is unclear While some previous studies have indicated that thrombus lacks the mechanical integrity to support much load compared with the aneurysm wall, others have shown that removing thrombus in computational AAA models drastically changes aneurysm wall stress. Histopathological studies have shown that thrombus properties vary through the thickness and it can be porous. The goal of this study is to explore the variations in thrombus properties, including the ability to isolate pressure from the aneurysm wall, incomplete attachment, and their effects on aneurysm wall stress, an important parameter in determining risk for rupture. An analytical model comprised of cylinders and two patient specific models were constructed with pressurization boundary conditions applied at the lumen or the thrombus/aneurysm wall interface (to simulate complete transmission of pressure through porous thrombus). Aneurysm wall stress was also calculated in the absence of thrombus. The potential importance of partial thrombus attachment was also analyzed. Pressurizing at either surface (lumen versus interface) made little difference to mean von Mises aneurysm wall stress values with thrombus completely attached (3.1% analytic, 1.2% patient specific) while thrombus presence reduced mean von Mises stress considerably (79% analytic, 40-46% patient specific) in comparison to models without it. Peak von Mises stresses were similarly influenced with pressurization surface differing slightly (3.1% analytic, 1.4% patient specific) and reductions in stress by thrombus presence (80% analytic, 28-37% patient specific). The case of partial thrombus attachment was investigated using a cylindrical model in which there was no attachment between the thrombus and aneurysm wall in a small area (10 deg). Applying pressure at the lumen resulted in a similar stress field to fully attached thrombus, whereas applying pressure at the interface resulted in a 42% increase in peak aneurysm wall stress. Taken together these results show that the thrombus can have a wall stress reducing role even if it does not shield the aneurysm wall from direct pressurization as long as the thrombus is fully attached to the aneurysm wall. Furthermore, the potential for porous thrombus to transmit pressure to the interface can result in a considerable increase in aneurysm wall stress in cases of partial attachment. In the search for models capable of accurately assessing the risk for rupture, the nature of the thrombus and its attachment to the aneurysm wall must be carefully assessed. [DOI: 10.1115/1.4001253]
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Local Diameter, Wall Stress, and Thrombus Thickness Influence the Local Growth of Abdominal Aortic Aneurysms
    Martufi, Giampaolo
    Liljeqvist, Moritz Lindquist
    Sakalihasan, Natzi
    Panuccio, Giuseppe
    Hultgren, Rebecka
    Roy, Joy
    Gasser, T. Christian
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (06) : 957 - 966
  • [2] Novel risk predictor for thrombus deposition in abdominal aortic aneurysms
    Nestola, M. G. C.
    Gizzi, A.
    Cherubini, C.
    Filippi, S.
    Succi, S.
    EPL, 2015, 112 (02)
  • [3] The role of intraluminal thrombus formation for expansion of abdominal aortic aneurysms
    Brunner-Ziegler, Sophie
    Hammer, Alexandra
    Seidinger, Daniela
    Willfort-Ehringer, Andrea
    Koppensteiner, Renate
    Steiner, Sabine
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (13-14) : 549 - 554
  • [4] Effect of macroscale formation of intraluminal thrombus on blood flow in abdominal aortic aneurysms
    Raptis, Anastasios
    Xenos, Michalis
    Dimas, Stelios
    Giannoukas, Athanasios
    Labropoulos, Nicos
    Bluestein, Danny
    Matsagkas, Miltiadis I.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (01) : 1 - 9
  • [5] A Computational Model of Biochemomechanical Effects of Intraluminal Thrombus on the Enlargement of Abdominal Aortic Aneurysms
    Lana Virag
    John S. Wilson
    Jay D. Humphrey
    Igor Karšaj
    Annals of Biomedical Engineering, 2015, 43 : 2852 - 2867
  • [6] A Computational Model of Biochemomechanical Effects of Intraluminal Thrombus on the Enlargement of Abdominal Aortic Aneurysms
    Virag, Lana
    Wilson, John S.
    Humphrey, Jay D.
    Karsaj, Igor
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (12) : 2852 - 2867
  • [7] Influence of gender on intraluminal thrombus of abdominal aortic aneurysms
    Yasuhara, H
    Ohara, N
    Nagawa, H
    AMERICAN JOURNAL OF SURGERY, 2001, 182 (01) : 89 - 92
  • [8] Impact of poroelasticity of intraluminal thrombus on wall stress of abdominal aortic aneurysms
    Polzer, Stanislav
    Gasser, T. Christian
    Markert, Bernd
    Bursa, Jiri
    Skacel, Pavel
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [9] Thrombus volume is similar in patients with ruptured and intact abdominal aortic aneurysms
    Golledge, Jonathan
    Iyer, Vikram
    Jenkins, Julie
    Bradshaw, Barbara
    Cronin, Oliver
    Walker, Philip J.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (02) : 315 - 320
  • [10] Analysis of morphological and hemodynamical indexes in abdominal aortic aneurysms as preliminary indicators of intraluminal thrombus deposition
    Colciago, Claudia M.
    Deparis, Simone
    Domanin, Maurizio
    Riccobene, Chiara
    Schenone, Elisa
    Quarteroni, Alfio
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2020, 19 (03) : 1035 - 1053