Antibiotic stability in portable elastomeric infusion devices: A systematic review

被引:13
作者
Esteban-Cartelle, Beatriz [1 ,2 ]
Vicente-Oliveros, Noelia [1 ]
Perez Menendez-Conde, Covadonga [1 ]
Serrano, Dolores R. [2 ]
Martin-Davila, Pilar [3 ]
Fortun-Abete, Jesus [3 ]
Leon-Gil, Lourdes A. [1 ]
alvarez-Diaz, Ana [1 ]
机构
[1] Ramon y Cajal Univ Hosp, Pharm Dept, Madrid, Spain
[2] Univ Complutense Madrid, Sch Pharm, Dept Pharmaceut & Food Technol, Madrid, Spain
[3] Ramon y Cajal Univ Hosp, Serv Infect Dis, Madrid, Spain
关键词
antibiotic; elastomers; infusion pumps; outpatient parenteral antimicrobial therapy; stability; POLYVINYL-CHLORIDE BAGS; PARENTERAL ANTIMICROBIAL THERAPY; CHEMICAL-STABILITY; AMBULATORY-CARE; MEROPENEM; PUMPS; CEFTAZIDIME; CEFTAROLINE; TEMPERATURE; INJECTION;
D O I
10.1093/ajhp/zxac122
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose Although outpatient parenteral antibiotic therapy (OPAT) can be a good approach to treatment of infections, a lack of data regarding antibiotic stability in portable elastomeric infusion devices restricts its safe, appropriate, and effective use. The objective of this work was to complete a systematic peer-reviewed analysis of published articles about antibiotic stability in elastomeric infusion devices that provide evidence supporting their use in OPAT. A systematic review following PRISMA guidelines was conducted in January 2021 to identify published articles about antibiotic stability in portable elastomeric infusion devices. The databases used were PubMed, Embase, Web of Science, and a Cochrane database. A total of 1,615 original studies and conference communications were found. After title, abstract, and full-text review, 33 articles met the inclusion criteria. The data obtained included information about the stability of 30 different antibiotics. To our knowledge, this is the first review to summarize the available published data on the stability of antibiotics in portable elastomeric infusion devices. The results highlight the poor stability of some antibiotics in solution and the variability of the laboratory conditions in the included studies. Conclusion This systematic review can serve as a useful resource for healthcare professionals involved in providing OPAT using portable elastomeric infusion devices. However, further stability studies should be performed, especially high-quality studies simulating real-life time and temperature conditions.
引用
收藏
页码:1355 / 1368
页数:14
相关论文
共 54 条
[1]   Stability of colistimethate sodium in a disposable elastomeric infusion device [J].
Abdulla, Alan ;
van Leeuwen, Roelof W. F. ;
Schultink, Aurelia H. M. de Vries ;
Koch, Birgit C. P. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 486 (1-2) :367-369
[2]  
Adelfred A., 2014, EUR J HOSP PHARM, V21, pA63, DOI [10.1136/ejhpharm-2013-000436.155, DOI 10.1136/EJHPHARM-2013-000436.155]
[3]   Stability of antimicrobial agents in an elastomeric infusion pump used for outpatient parenteral antimicrobial therapy [J].
Akahane, Mutsumi ;
Enoki, Yuki ;
Saiki, Reika ;
Hayashi, Yukitaka ;
Hiraoka, Kana ;
Honma, Kyoka ;
Itagaki, Marina ;
Gotoda, Mai ;
Shinoda, Kozue ;
Hanyu, Satomi ;
Hamamura, Yuna ;
Miyajima, Taichi ;
Ito, Chihiro ;
Taguchi, Kazuaki ;
Uno, Shunsuke ;
Uwamino, Yoshifumi ;
Iketani, Osamu ;
Hasegawa, Naoki ;
Matsumoto, Kazuaki .
INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2021, 103 :464-468
[4]   Physical and chemical stability of ceftaroline in an elastomeric infusion device [J].
Al Madfai, Farah ;
Zaidi, Syed Tabish R. ;
Ming, Long Chiau ;
Wanandy, Troy ;
Patel, Rahul P. .
EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2018, 25 (E2) :E115-E119
[5]  
Allen, STRENGTH STABILITY T
[6]   Stability of 14 drugs in the latex reservoir of an elastomeric infusion device [J].
Allen, LV ;
Stiles, ML ;
Prince, SJ ;
Smeeding, J .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1996, 53 (22) :2740-2743
[7]   Assessment of the stability of citrate-buffered flucloxacillin for injection when stored in two commercially available ambulatory elastomeric devices: INfusor LV (Baxter) and Accufuser (Woo Young Medical): a study compliant with the NHS Yellow Cover Document (YCD) requirements [J].
Allwood, Michael Charles ;
Stonkute, Donata ;
Wallace, Andrew ;
Wilkinson, Alan-Shaun ;
Hills, Tim ;
Jamieson, Conor .
EUROPEAN JOURNAL OF HOSPITAL PHARMACY, 2020, 27 (02) :90-94
[8]   Stability of antibiotics in portable pumps used for bronchial superinfection: Guidelines for prescribers [J].
Arlicot, Nicolas ;
Rochefort, Gael Y. ;
Schlecht, Deborah ;
Lamoureux, Fabien ;
Marchand, Sophie ;
Antier, Daniel .
PEDIATRICS, 2007, 120 (06) :1255-1259
[9]   STABILITY OF CEFTAZIDIME (WITH ARGININE) IN AN ELASTOMERIC INFUSION DEVICE [J].
BEDAR, DA ;
KLUTMAN, NE ;
HENRY, DW ;
FOX, JL ;
STRAYER, AH .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 1995, 52 (17) :1912-1914
[10]  
Bhattacharya Sisir, 2015, Int J Pharm Compd, V19, P432